BBC NYHAVN is a 2012 public freight. The Coast Guard has recorded 17 inspections since 2016, most recently in July 2025, along with 11 deficiencies and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 17 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it6351 - Convention (Subpart B), Gross Ton 9721 - Dead Weight, Metric Ton 3617 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
17 July 2025PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8187975
3 September 2024PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7995208
23 August 2024Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7987866
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 March 2023Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSC Officers were unable to verify operation of audible alarm of smoke detection system. After troubleshooting, crew was able to get alarm working as designed. SOLAS 74 (2009 Cons.) II-2/14.1.1.
Action required: 10 - Deficiency Rectified
Resolved 7 March 2023
Resolution: After troubleshooting, crew was able to get alarm working as designed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2021Resolved
PSCO's observed pin inserted in the first CO2 cylinder of 21 cylinders, preventing the remote discharge of the required number of bottles to the protected space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 August 2021
Resolved 27 August 2021
Resolution: Pin was removed from cylinder
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 June 2021Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed pooling fuel oil of a depth up to two inches around cylinder No. eight. In addition the remaining cylinders were covered in fuel oil.
- 47SOLAS(14)II-2/4.1.1 (17ac)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2021
Resolution: Class survey report was provided clearing the deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 June 2021Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a plastic hose from main engine lube oil pipe being drained into a bucket.
- 74SOLAS(14)II-2/4.1.1 (17ac)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2021
Resolution: Class survey report was provided clearing the deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2021Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed overhead diesel pipe in the prurifier room leaking onto the heating element for oil purifier.
- 74SOLAS(14)II-2/4.1.1 (17ac)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2021
Resolution: Class survey report was provided clearing the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2021Resolved
Nonconducting mats or gratings shall be provided at the front and rear of the switchboard. PSCO observed no matting around any electrical switchboards in the engine room.
- 74SOLAS(14)II-1/4.5.2 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 5 June 2021
Resolution: Class survey report was provided. Condition of class was issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2021Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self igniting lights. PSCO observed multiple lifebuoy configurations with lights that were not self igniting.
- 74SOLAS(14)III/7.1.3 (16ac)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 5 June 2021
Resolution: Class survey report was provided. Condition of class was issued.
The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed oxygen bottles being stored on deck, secured with a single strap adjacent to acetylene storage locker.
- 74SOLAS(14)I/11(a) (40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2021
Resolution: Class survey report was provided. Condition of class was issued.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2016
Resolution: Received, reviewed and accepted class report from BV and marine chemist certificate certifying the engine room was "safe for workers" prior to vessel's departure from port. Class surveyor also conducted satisfactory operation test of OWS with no issues.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 21 March 2016Resolved
SEE NARRATIVE FOR DEFICIENCY 2
74SOLAS(14)III/14.1
Condition: Improper/Lack of Maintenance
Due 21 March 2016
Resolved 21 March 2016
Resolution: CORRECTED ON THE SPOT
Fire Fighting › Structural - Main Vertical Zones › General
Issued 21 March 2016Resolved
SEE NARRATIVE FOR DEFICIENCY 03
74SOLAS(14)II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Due 21 March 2016
Resolved 21 March 2016
Resolution: CORRECTED ON THE SPOT
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.