← All vessels
LANGEOOG
LANGEOOG is a 2013 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in July 2026, along with 3 deficiencies — 1 with no resolution recorded — and 2 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 16 July 2026.
- Built
- 2013
- Last inspected
- 15 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9506136 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2GK5
1270772
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1270772
Inspections, by type
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it4591 - Convention (Subpart B), Gross Ton
5463 - Dead Weight, Metric Ton
8440 - Displacement, Metric Ton
1966 - Convention (Subpart B), Net Ton
5463 - Dead Weight, Metric Ton
8440 - Displacement, Metric Ton
1966 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
15 July 2026
Administrative Inspection · In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8438600
8 March 2026
PSC B
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8320489
3 August 2021
Ballast Water Examination · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7275863
2 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7275980
28 July 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7270587
12 December 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6056220
21 November 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6045026
Deficiency record · 3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 July 2026
No resolution recorded
A main source of electrical power of sufficient capacity to supply all those services mention in regulation 40.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. PSCO observed an inoperable No.2 Ship Service Diesel Generator and IAW REG. II-1/41.3 the vessels main source of power shall be maintained regardless of speed and direction or rotation of propulsion machinery or shafting (shaft generator), leaving only 1 operable ship service generator to provide power for a main power source. 74SOLAS(04) II-1/41.1
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 21 November 2016
Resolved
0730 - Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump does not provide adequate pressure to hose on bridge wing. Same test with main fire pump yielded adequate pressure. 74SOLAS(14)II-2/14.2.1.2 17AC
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 November 2016
Resolved
0820- All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in any normal manner. Several guards on electric motor of refridgerant compressor for provisions space were missing or replaced with rags, casuing exposed wiring and machinery. 74SOLAS(04cons)II-1/45.1.3 40AC
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.