MAURY USCG vessel records
← All vessels

LINDA D

LINDA D is a 2001 freight ship. The Coast Guard has recorded 33 inspections since 2016, most recently in September 2024, along with 29 deficiencies and 5 operational controls.

Records from 2016 to 2024. Most recent: operational control imposed, 22 November 2024.

Built
2001
Last inspected
19 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 September 2024
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9261164
HO8554
1271158
Flag
PANAMA
Maury page id
psix-1271158

Documentation record

Tonnage as PSIX records it327 - Convention (Subpart B), Net Ton
1092 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

19 September 2024 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8009562
29 May 2024 Ballast Water Examination · PSC B · ISPS Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7922754
29 April 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7903436
2 April 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7885144
2 October 2023 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7798076
17 July 2023 Appeal
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7745048
3 April 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7661632
14 March 2023 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7647650
23 February 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7638755
13 March 2022 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7410843
14 September 2021 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7310244
26 March 2021 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7163375
15 March 2021 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7156189
17 November 2020 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7097095
14 September 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7055798
14 July 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7005996
3 March 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6916856
26 August 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6789420
8 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6621953
7 February 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6630520
18 August 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6517501
9 August 2018 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6504847
9 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6352413
2 January 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6336298
2 January 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346820
10 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6235968
13 February 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6087153
7 February 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084125
4 August 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5962561
20 April 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5858751
2 March 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5825277
16 February 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5816248
29 January 2016 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5805886

Deficiency record · 29

10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 September 2024 Resolved
Contracting governemnts, for its national ships, undertake to ensure that all ships be sufficiently and efficiently manned. LINDA D does not have cremembers on board meeting the requirements of the ships minimum safe manning document. SOLAS 74(2020 Cons.)V/14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2025
Resolution: All crew credentials sat verified against MSM.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 May 2024 Resolved
Stairways and ladders shall be so arranged as to provide...ready means of escape to the open deck. Escape hatch blocked by handrail.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 May 2024
Resolution: Cleared on site
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2024 Resolved
No less than two of these (lifebuoys) shall be capable of quick release from the bridge. Quick release pin unserviceable and twisted around the frame.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 May 2024
Resolution: Pin replaced, deficiency rectified on site.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 23 February 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The objective evidence of the deficiencies below brings into question the validity of the safety management system as required in the ISM Code. An audit is required to be submitted to the Coast Guard prior to depart. The vessel's SMS states: Vessel's safety and operations manual; shipboard operations - engine room machinery, engineer duties and knowledge to include: oil record book maintained IAW MARPOL Regulations, Fire precaution in machinery spaces to provide proper cleaning, especially oil spills and leaks. Cargo operations; load cargo IAW specific approved manuals, e.g., stability manual, cargo securing manual. During an examination of the Oil Record Book (ORB), PSCO found that incorrect codes have been used for the last three years of ORB logbook entries. During the engine room examination, PSCO observed insufficient cleanliness of engin room with excess amount of oily mixture in bilges. During the deck walk examination, PSCO found that both starboard and port load lines were fully submerged. 74 SOLAS 01 IX/3.1 ISM CODE PART A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 March 2023
Resolution: Vessel contacted class to conduct an audit and reviewed all pertinant deficencies. Deficencies rectified to satisfaction of USCG and Class. Report in documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 23 February 2023 Resolved
The appropriate load lines on the sides of the ship shall not be submerged at any time when the ship puts to sea. The port and starboard load lines were found fully submerged. On the port side, the entire plimsol mark is submerged, and the starboard load line is submerged two inches. ICLL 66 Art. 12(1)
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 3 March 2023
Resolution: Vessel contacted class to conduct an audit and reviewed all pertinant deficencies. Deficencies rectified to satisfaction of USCG and Class. Report in documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 February 2023 Resolved
The purpose of this chapter is to require the fullest practicable degree of fire protection. PSCO observed insufficient cleanliness of engine room with excess amount of oily water mixture in bilges, creating an excessive fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 March 2023
Resolution: Vessel contacted class to conduct an audit and reviewed all pertinant deficencies. Deficencies rectified to satisfaction of USCG and Class. Report in documents.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 February 2023 Resolved
The Oil Record Book, whether as a part of the ship’s official log book or otherwise, shall be in the form specified in Appendix III to this Annex. Disposal of bilge water which has accumulated in machinery spaces shall be recorded as a code (letter) (D) with corresponding item (number), vessel’s CE is recording the method of discharge, transfer, or disposal of bilge water as a code C item 11 and 12.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2023
Resolution: Vessel contacted class to conduct an audit and reviewed all pertinant deficencies. Deficencies rectified to satisfaction of USCG and Class. Report in documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 February 2023 Resolved
Fire extinguishers shall be periodically examined and subjected to such tests as the Administration may require. Fire extinguisher #11 (per the fire control plan) within the engine room was found with no charge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 15 March 2021 Resolved
02 of 04 Line throwing appliances are expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 March 2021
Resolved 16 March 2021
Resolution: Vessel proved receipt of 02 new line throwing appliances within expiration time period.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 March 2021 Resolved
Doors fitted in boundary bulkheads shall be gas tight and sef closing. Emergency escape door in engine room was not closing/missing handle. 97SOLAS II-2 47.1 16 b,c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 26 March 2021
Resolution: Vessel management sent pictures and video of proper operation of the door.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 9 August 2018 Resolved
1110 - Cargo Operations - All cargoes other than solid and liquid bulk cargoes , cargo units and cargo tranport units, shall be loaded, stowed, and secured throughout the voyage in accordance with the cargo securing manual approved by the Administration. Cargo securing manual requires that container twistlocks be welded to the deck. Twistlocks are not welded and are wasted and rusted preventing them from being locked. - 74SOLAS(14 Cons.) VI/5.6 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2018
Resolved 12 September 2018
Resolution: Class submitted attestation. Twistlocks have been replaced and welded to the deck.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Sulphur oxides
Issued 9 August 2018 Resolved
2490 - For each ship subject to regulations 5 and 6 of this Annex, details of fuel oil for combustion purposes delivered to and used onboard shall be recorded by means of bunker delivery notes that shall contain at least the information specified in appendix V to this Annex. Chief Engineer could not provide PSCO's with Sulphur content of recent fuel deliveries. - MARPOL(17 Cons.) Annex VI/18.3.5 - 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 August 2018
Resolved 10 August 2018
Resolution: Vessel provided delivery notes of the past fuel deliveries. Sulfur content was listed on the back page of each delivery note but the chief engineer was not checking when signing the paperwork. He was instructed to verify Sulphur content upon each delivery
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 9 August 2018 Resolved
1030 - Steering Gear Alarm - In the event of a power failure to any one of the steering gear power units, an audible alarm and visual alarm shall be given on the navigation bridge. Audible alarm on bridge is inoperable. - 74SOLAS(04 Cons.) II-I/29.5.2 - 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2018
Resolved 10 August 2018
Resolution: Technician repaired the alarms on the bridge. PSCO witnessed satisfactory test of alarms on the bridge.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 9 August 2018 Resolved
1030 - Sterring Gear Alarm - A low level alarm for each hydraulic fluid resevior to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge. There are no low-level alarms on the navigation bridge. - 74SOLAS(04 Cons.) II-I/29.12.2 - 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2018
Resolved 10 August 2018
Resolution: Technician repaired the alarms on the bridge. PSCO witnessed satisfactory test of alarms on the bridge.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 9 August 2018 Resolved
0735 - Personal Equipment - Four sets of full protective clothing resistant to chemical attack shall be provided in addition to the firemans's outfits required by regulation 17. Vessel is authorized to carry dangerous goods. Vessel crew could not provide the four chemical suites that are required to be kept onboard. - 74SOLAS(01 Cons.) II/2/54.2.6.1 - 16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 18 September 2018
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 10 August 2017 Resolved
Self-activating smoke signals shall be provided with a quick-release arrangement that will automatically release and activate the signal and associated self-igniting light connected to a lifebuoy having a mass of 4kg. Both quick release lifebuoys are unable to self-activate smoke signal.- 74 SOLAS (14 Cons.) III/34 - 17 LSA II/2.1.3.6
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 4 October 2017
Resolution: Flag attestation received. Lifebuoy setup corrected.
Lifesaving › Lifebuoys › Size
Issued 10 August 2017 Resolved
Every lifebuoy intended for quick-release shall have a mass not less than 4kg. Starboard quick-release lifebuoy has a mass less than 4kg. - 74 SOLAS (14 Cons.)III/34 - LSA II/2.1.1.7
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 4 October 2017
Resolution: Flag attestation recieved. Lifebuoy replaced with correct size.
Engineering › Fuel Oil Service System › Valve
Issued 10 August 2017 Resolved
Oil level gauges with flat glasses and self-closing valves between gauges shall be maintained in the proper condition to ensure accurate function. Self-closing valves on dirty oil, day tank and fuel oil tank were permanently fixed in open position. - 74 SOLAS (2001 Cons.) II-2/15.2.6.2.2
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 4 October 2017
Resolution: Flag attestation received. Engineering controls removed preventing self-closing and reprimand given.
Lifesaving › Inflatable Liferafts › Float Free
Issued 13 February 2017 Resolved
SOLAS 14(cons) III/13.4.2 - Each liferaft shall be stowed with a float-free arrangement so that each floats free. Port and Starbaord liferafts had sea painter lines which were tied to the ship instead of the weak link. Both arrangements were corrected on the spot.
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Documentation › Logs/Records › Logbook (official)
Issued 13 February 2017 Resolved
SOLAS 14(cons) V/28.1 - All ships shall keep on board a record of navigation activities which much contain sufficient detail to restore a complete record of the voyage. The bridge log book contained inaccurate time/date of pilot onboard and lacked destination of voyage.
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Engineering › Fuel Oil Service System › Valve
Issued 4 August 2016 Resolved
0750 - Oil-Level gauges with flat glasses and self-closing valves between gauges shall be miantained in the proper condition to ensure accurate function. Self-closing valves on dirty oil, day tank and fule oil tank were permanently fixed in the open position. 74 SOLAS (2001 CONS) II-2/15.2.6.2.3
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 August 2016
Resolution: Corrected on the spot by removing all apparatuses that kept the valves open.
Engineering › Steering Gear System › Power Unit
Issued 21 April 2016 Resolved
The condition of the ship and its equipmemt shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respect will remain fit to proceed to sea without danger to the ship or persons on board. Vessel lost main steering during manuvering drills while enroute to Port Everglades. The steering loss was due to a faulty breaker. 74 SOLAS (2014) 1/11a
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: cleared on the spot, class report attached
Engineering › Bilge Water Management System › Pump
Issued 29 January 2016 Resolved
1099: Bilge wells shall be monitored in such a way that accumulation of liquids is detected. Bilge alarms located in engine room and steering gear room had rags around float preventing actuation and removed from bilge well in steering gear room. 74 SOLAS (04 Cons) II-2 Reg 48.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2016
Resolution: Rags were removed from the bilge alarm floats.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 January 2016 Resolved
0750: Doors required to be self-closing shall not be fitted with hold back hooks. Door to engine room and escape trunk door were held open with hold back hooks and stairway trunk door was not self-closing. 74 SOLAS (01 Cons) Ch II-2/Reg 47.2
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2016
Resolved 2 March 2016
Resolution: Verified all doors self-closing.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 January 2016 Resolved
0750: All waste receptacles shall be constructed of non-combustible material. Waste receptacle in engine room is made of plastics. 74 SOLAS (01 Cons) Ch II-2/Reg 18.5
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2016
Resolution: Waste receptacle in engine room was removed. A metal waste receptacle is on order.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 January 2016 Resolved
0660: Life jackets shall be constructed so that the method of securing the life jacket has a quick and positive means of closure that does not require tying of knots. Life jackets onboard were found to be secured by tying knots. 74 SOLAS (14 Cons) Ch III/Reg 7.2.2.1 / LSA Code Ch II/2.2.1.5.4
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2016
Resolved 12 February 2016
Resolution: Vessel replaced lifejackets
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 January 2016 Resolved
0799: Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Secondary means of releasing CO2 fixed fire extinguishing agent for engine room is obstructed by stowage of SOPEP gear. 74 SOLAS (14 Cons) Ch II-2/Reg 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2016
Resolved 12 February 2016
Resolution: SOPEP equipment was moved to another location.
Construction/Loadline › Structures › Door
Issued 29 January 2016 Resolved
1270: All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel fitted so that it is weather-tight when closed. Second deck starboard door lower coaming is wasted/holed and not weather-tight. ILLC 12.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2016
Resolved 2 March 2016
Resolution: Verified door coaming repaired by welding.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 January 2016 Resolved
1720: A ship of 300 GT or more must have a fixed container under each fuel oil tank vent, overflow, and fill pipe that has a capacity of at least one-half barrel. Fuel oil fill pipes and tank vents do not have adequate containment capacity. 33 CFR 155.320
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 March 2016
Resolved 2 March 2016
Resolution: Verified containment meets .5 bbl requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.