MAURY USCG vessel records
← All vessels

HAPPY SKY

HAPPY SKY is a 2013 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in October 2024, along with 2 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 17 October 2024.

Built
2013
Last inspected
17 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9457220
1271166
Flag
NETHERLANDS
Maury page id
psix-1271166

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 4 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it15989 - Convention (Subpart B), Gross Ton
17778 - Dead Weight, Metric Ton
28214 - Displacement, Metric Ton
4989 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

17 October 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8018317
26 February 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6916196
3 January 2020 PSC C
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6882135
16 August 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6500429
4 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6365433
25 October 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6029593

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 January 2020 Resolved
07105 - Fire doors/openings in fire-resisting divisions. "A" Class divisions are those divisions formed by bulkheads and decks which comply with the following... they are so constructed as to be capable of preventing the passage of smoke and flame... Steering gear room does not properly seal due to door mis-allignment and deteriorated seal. Additionally the steering gear room door leading to the engine room storage space has a penetration which has been duck taped to cover the hole. Both doors are certified as class "A" fire boundary doors. 74SOLAS(04)II-2/3.2 AND 3.4.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2020
Resolved 26 February 2020
Resolution: Recieved classification documentation attesting to repair
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 January 2020 Resolved
07105 - Fire doors/openings in fire-resisting divisions. Doors required to be self-closing shall not be fitted with hold-back hooks... Hold back hooks were present on self-closing doors leading to the ECR. 74SOLAS(04)II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 January 2020
Resolved 3 January 2020
Resolution: Hold back hooks that were present on the self-closing doors leading to the ECR. Were removed by ships crew prior to port state control departure.

Ownership record