Records from 2015 to 2023. Most recent: inspection, 16 November 2023.
Inspection history · 18
16 November 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7825689
4 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7732243
16 December 2022
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7609989
10 May 2022
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7447401
21 March 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7415356
31 March 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7166086
20 March 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6645746
28 October 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6570922
22 October 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6565855
20 October 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6564864
13 April 2018
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6391094
14 February 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6354863
3 August 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6228978
3 August 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6229378
27 February 2017
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6095283
18 January 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6072516
22 December 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5785799
24 July 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5194643
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 December 2022
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
Initial test of emergency fire pump failed to produce necessary water pressure.
74 SOLAS (20) II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Due 16 December 2022
Resolved 16 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2022
Resolved
Fire doors in galley boundaries shall be self closing. Hold-back hooks not subject to central control station release are prohibited.
Marine inspector observed hold-back devices not subject to central control on all galley A-class boundary doors.
74 SOLAS (20) II-2/9.4.1.1.5.1.4
Action required: 10 - Deficiency Rectified
Due 16 December 2022
Resolved 16 December 2022
Engineering › Fuel Oil Service System › Piping
Issued 14 February 2018
Resolved
01 Code: 1499 Means shall be prepared to control leaks of flammable liquids. Steady diesel oil leak observed from seals located in pruifier space and in the vicinity of generators. Cite: 74SOLAS (09cons) II-2/4.1.1 Action Taken: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2018
Resolved 16 February 2018
Resolution: Vessel's Classification Society provided a report attesting to the repair/replacement of leaking gaskets in the purifier room and IVO generators.
Engineering › Fuel Oil Service System › Piping
Issued 14 February 2018
Resolved
02 Code: 0830 Surfaces with temperatures above 220 degrees C which may be impinged as a result of a fuel system failure shall be properly insulated. Areas in the engine room where lagging is required were found damaged and/or missing. Cite: 74SOLAS (09cons) II-2/4.2.2.6 Action Taken: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2018
Resolved 16 February 2018
Resolution: Vesse'l Classification Society provided a report to attest to the installation of missing lagging on surfaces in which insulation was required.
Engineering › Fuel Oil Service System › Piping
Issued 14 February 2018
Resolved
03 Code: 1470 In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil. Areas in the engine room where lagging is installed were found to be saturated with oil. Oil saturated lagging was primarily found in the purifier space and on the generator. Cite: 74SOLAS (09 cons) II-1/ 4.4.3 Action Taken: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2018
Resolved 16 February 2018
Resolution: Vessel's Classification Society provided a report attesting to the replacement of oil soaked lagging found in the purifier space and affixed to the vessel's generators.
Engineering › Steam System (main) › Piping
Issued 14 February 2018
Resolved
04 Code: 1499 Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. A steam leak was found in the purifier space and adjacent to the HFO settling tank #2. Cite: 74SOLAS (04 cons) II-1/33/1 Action Taken: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2018
Resolved 16 February 2018
Resolution: Vessel's Classification Society provided a report attesting to the replacement/repair of gaskets found leaking on the vessel's steam system, specifically in the purifier space and adjacent to the HFO #2 settling tank.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 January 2017
Resolved
74 SOLAS (14) V/19.2.7.1 - All ships 3,00 gross tons and above shall have a 36hz radar or a second 96 hz radar which are functional independent of eachother. Vessels 96hz radar's hard drive crashed while in port at global marine terminal bayonne, NJ. Vessel recieved letter of dispensation from their flag state stating that their 36hz radar will operate as pimary radar, the 96hz radar will be fixed
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 18 January 2017
Resolution: Corrected On Site
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 January 2017
Resolved
MARPOL Annex 1/16.2 - Any vessel 10,000 gross tons and above shall be privided with oil filtering equipment with an alarm and shutdown of any discharge of oily mixtures with the effluent exceeding 15ppm. Vessel's OWS was found inoperable. Vessel shall tag out OWS and make arrangements for lal oily water mixtures to be retained onboard and subsequently discharged at reception facility until repairs
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 February 2017
Resolution: Received class report and copies of the new IOPP for the proper operations of the OWS.