MAURY USCG vessel records
← All vessels

ROZO TIDE

ROZO TIDE is a 2012 offshore supply vessel. The Coast Guard has recorded 2 inspections since 2017, most recently in November 2022, along with 3 deficiencies.

Records from 2017 to 2022. Most recent: inspection, 14 November 2022.

Built
2012
Last inspected
14 November 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 November 2022
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9617791
1271327
Flag
MEXICO
Maury page id
psix-1271327

Documentation record

Tonnage as PSIX records it869 - Convention (Subpart B), Net Ton
2899 - Convention (Subpart B), Gross Ton
3000 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

14 November 2022 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7583145
20 August 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6207640

Deficiency record · 3

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 November 2022 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500L and above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed fuel shutoff valve nonoperational. SOLAS 74 (20) II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2022
Resolution: Received class survey. Def closed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2022 Resolved
The following fire protection systems shall be kept in good order: fireresisting divisions and protection of openings. PSCO observed self closing doors in engine room unable to operate as intended. Verify all self closing doors are operational and consistent with fire control plan. SOLAS 74 (20) II-2/14.2.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2022
Resolution: Class survey received. Def closed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2022 Resolved
The following fire protection systems shall be kept in good order: structural fire protection, including fire-resisting divisions and protection of openings and penetrations in these divisions. PSCO observed multiple hold back hooks preventing self closing doors on main deck. SOLAS 74 (20) II-2/14.2.1.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 November 2022
Resolution: Class survey received. Def closed

Ownership record