MAURY USCG vessel records
← All vessels

DART TRADER

DART TRADER is a 2011 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in July 2025, along with 8 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 2016 to 2025. Most recent: operational control imposed, 11 July 2025.

Built
2011
Last inspected
11 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

9566813
1271345
Flag
LIBERIA
Maury page id
psix-1271345

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it43501 - Convention (Subpart B), Gross Ton
93374 - Displacement, Metric Ton
79467 - Dead Weight, Metric Ton
27819 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 10

11 July 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8184871
2 January 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7841283
22 December 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7841633
29 October 2021 Administrative Inspection · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7329528
15 February 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626420
15 February 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626675
13 February 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6614685
25 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6614933
27 November 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6047998
18 October 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6018785

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 January 2024 Resolved
Before the ship leaves port and at all times during voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO obeserved inoperable rescue boat davit failure due to electric motor failure. 74SOLAS(20)III/20.2 17BC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2024
Resolution: Vessels flag submitted new dispensation letter that extends rectification to 29FEB24. Vessel submitted risk mitigation plan and ST safety equipment cert.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 January 2024 Resolved
The means for securing these doors weathertight shall consist of gaskets and clamping devices or equivalent means, doors shall be so arranged that they can be operated from both side of the bulkhead. PSCO observed broken dog on B deck starboard side exit door. ICLL 12(1) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2025
Resolution: Received class report attesting to deficiency rectification.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 January 2024 Resolved
Following installation, owner/operator must properly maintain the BWMS in accordance with the manufacture specifications. PSCO observed faulty BWTS automatic monitoring system. 33CFR151.2025(a)(1) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2025
Resolution: Received class report attesting to deficiency rectification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 January 2024 Resolved
Efficient guard rails or bulworks shall be fitted to all exposed parts of the freeboard and superstructure decks. PSCO observed broken bottom rail along side near cargo hold 2. ICLL25(2) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2025
Resolution: Received class report attesting to deficiency rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 January 2024 Resolved
Before the ship leaves port and at all times during voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboat engine did not start immidiately. Crew repaired and fuction normally. 74SOLAS(20)III/20.2 10C
Action required: 10 - Deficiency Rectified
Resolved 4 January 2024
Resolution: corrected on the spot. Lifeboat was able to start and fully operational 20 minutes after requesting inital test start.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2021 Resolved
When a distribution system, whether primary or secondary, for power, heating or lighting, with no connection to earth is used. PSCO observed a ground on switchboard. 74 SOLAS (20) II-1/45.4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 November 2021
Resolved 22 December 2023
Resolution: SEC VA received Class Report attesting to no ground fault on the main switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2019 Resolved
74SOLAS(09) II-1/40.1.3 The Electrical installations shall be such that the safety of passengers crew and ship from electrical hazzards will be ensured. PSCO noted exposed wiring on main engine fuel supply unit. 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2019
Resolution: Defective junctino box packing gland on the M/E Fuel Supply Unit was replaced with a new packing gland, cable verified to be in satisfactory condition. This is noted in attached Class survery report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2019 Resolved
74SOLAS(09) II-1/ 45.1.1 Exposed metal parts of electrical machines or equipment which are not inteded to be live but which are liable under fault conditions to become live shall be earthed. Psco noted 15 electrical components with missing ground wires. 17C
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2019
Resolution: PSCO verified that ground wires were re-attached or replaced in the applicable areas. General examintation of vessel did not reveal any additional missing grounding wires as noted in ABS statutory survey report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.