CMA CGM OTELLO is a 2005 freight ship. The Coast Guard has recorded 24 inspections since 2017, most recently in March 2026, along with 10 deficiencies and 5 operational controls.
Records from 2017 to 2026. Most recent: inspection, 2 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it91410 - Convention (Subpart B), Gross Ton 48921 - Convention (Subpart B), Net Ton 101810 - Dead Weight, Metric Ton 135530 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 September 2023Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions. It was identified by the PSCO's that the maintenance by the the safety management system is incomplete. PSCO's observed that the hours in excess of maintenance intervals was observed for the crank case bearings, cross and main bearings. It was also observed that there was power irregularities with ships service generators 1, 2 and 5. Also there is piston ring clearance/tolerance on cyl1 and 2 on main diesel engine to include reported failures with the #6 cyl. MDE light pump actuator. Provide Corrective Action Plan prior to departure.
ISM CODE 10. 17 ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2023
Resolution: Received, reviewed and accepted corrective action plan to conducted overdue maintenance/repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 23 September 2023Resolved
The construction and the means for securing. It was identified by PSCO's that watertight integrity in accordance with load line cannot be attained2, manhole access to cargo hold 1,3,4,5 and 7 cannot be properly secured closed. Load Line 05 Regulation 14 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2023
Resolution: Received, reviewed and accepted BV class report stating that the watertight integrity has been returned to the manhole openings.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2023Resolved
For the period of 18hr., emergency lighting. PSCO identified multiple failed E lighting bulbs throughout vessel. Replace and attest to operational readiness.
SOLAS 74 II/1-43.2.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2023
Resolution: Received, reviewed and accepted BV class report attesting to the replacement/ repairs of all emergency lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2023Resolved
Unless Provided otherwise. PSCO that the rear seal on the hydraulic PTO for the #4 steering gear assembly has failed.
SOLAS 74 II/1-29 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2023
Resolution: Received, reviewed and accpeted BV class report attesting the the repairs of the hydraulic PTO for the #4 steering gear assembly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2023Resolved
A main source of electrical power of sufficent cpactiy to supply all those services mention in resolution 40.1. shall be provided. This main source shall consist of at least two generating sets.
Vessel provided dispensation for gensets #1 and 2. During course of inspection, gensets #3 and 5 were taken offline due to electrical faults, leaving only genset #4 fully fuctioning. Gernset #5 was repaired prior to departure of inpsection team.
SOLAS II-1/41.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2023
Resolved 15 September 2023
Resolution: Resolved while on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2022Resolved
The condition of the ship and its equipment shall be maintained to confrm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO's observed piping rupture in way of general service pump that was repaired with a box patch located in engine room floor deck.
74 SOLAS (2020 CONS.) CH 1/ REG 11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2023
Resolution: Vessel submitted statement of fact from class attesting on 06FEB2023 class attended the vessel and the repair of ruptured seawater pipe completed, vessel fit to proceed to sea.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 November 2022Resolved
74SOLAS(20)II-2/4.1.1 Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel soaked lagging on the return piping underneath the number 9 and 12 fuel injectors on the main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2022
Resolution: Received Class Report stating that the fuel soaked lagging was due to an overfill of oil while conducting maintenance that was not yet cleaned.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 26 November 2022Resolved
74SOLAS(20)II-1/3-1 Ships shall be designed, constructed, and maintained in accordance with the structural, mechanical, and electrical requirements of the classification society. PSCO observed fire alarm due to melted belt on a fan box supplying ventilation to the accommodation space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2022
Resolution: Received Class Report that attested to a new fan box installed to replace the damaged one.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 18 May 2017Resolved
0750 74SOLAS(2014CONS)CH.II-2/9.3.1 40ac - Where "A" class divisions are penetrated, such shall be insulated by extension of the insulation at the same level of the division. Discovered "A" class fire insulation missing around electrical cable penetrations through the overhead decka and passageway bulkhead in cable duct spaces on multiple decks.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 May 2017
Resolved 10 July 2017
Resolution: Cable duct spaces on C to G decks were definitively repaired and seal with approved "A-60 class" sealing compound. Visual inspection of sealed areas on penetrations was carried out with the general condition at the surveyor's satisfaction.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 May 2017Resolved
0750 74SOLAS(2014CONS)CH.II-2/9.4.2.2 10c - DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. HOWEVER, HOLD-BACK ARRANGEMENTS FITTED WITH REMOTE RELEASE DEVICES OF THE FAIL-SAFE TYPE MAY BE UTILIZED. HOLD BACK HOOKS WERE FOUND ON NUMEROUS DOORS REQUIRED BY THE FIRE PLAN TO BE SELF-CLOSING.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 May 2017
Resolution: DEFICIENCY WAS RECTIFIED DURING EXAM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.