Records from 2014 to 2025. Most recent: inspection, 12 August 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
12 August 2025
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8208299
8 August 2025
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8204813
19 April 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7898320
2 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7802115
8 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7554058
14 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7332653
1 September 2021
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7301837
5 August 2020
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7025454
19 February 2020
Administrative Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6931434
13 June 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6701929
28 May 2019
Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6699168
27 August 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6525369
29 August 2017
Administrative Inspection · Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6255483
11 July 2016
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5937337
2 June 2014
Simplified Stability Test · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4877491
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2025
Resolved
If a vessel completes a satisfactory alternate hull exam, with the underwater survey portion conducted predominantly by an approved underwater remotely operated vehicle (ROV), the vessel must undergo one alternate hull and one internal structural exam, within any five-year period. Vessel exceeded 5-year period listed on COI for hull examination. Hull examination must be completed by 18 AUG 2025.
46 CFR 176.600(e)
705c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2025
Resolved 18 August 2025
Resolution: Satisfactory AHE completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2025
Resolved
Approval of bowls of other than steel construction will specify if a flame shield is required. Racor fuel strainers for main engines do not have drip bowls as per manufacturer design.
46 CFR 182.455(b)(6)
16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 21 August 2025
Resolution: Heat shield bowls installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 August 2025
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Sea-Fire system service records must be provided.
46 CFR 176.810(b)(2)
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 21 August 2025
Resolution: Records provided
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 August 2025
Resolved
A vessel must comply with the applicable requirements for any radio...including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission. Station license was not available for review.
46 CFR 184.502
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 21 August 2025
Resolution: Def issued in error, Radio rules do not apply to this vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets must be segregated from adult life jackets.
46 CFR 180.78(a)(5)
16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 21 August 2025
Resolution: Life Jacket stowage area properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Marking for number of child life jackets stored above operating station is required.
46 CFR 185.604(f)
16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 21 August 2025
Resolution: Life Jacket stowage area properly labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 September 2021
Resolved
Repair or replace cracked window in the main cabin, port side.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 14 October 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 September 2021
Resolved
Limit the amount of combustible material stored below decks to items necessary to daily operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 14 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 September 2021
Resolved
Attach a restraining lanyard to prevent the forward and aft hatches from falling overboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2021
Resolved 14 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 2 September 2021
Resolved
Secure grill propane tank to prevent movement when underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 14 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2020
Resolved
Install junction box covers on all led light fixtures on the upperdeck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 2 September 2020
Resolution: Electrical connections were installed in weathertight junction boxes.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 August 2020
Resolved
Replace missing speaker for the aft deck PA system
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 2 September 2020
Resolution: A new PA speaker was installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2019
Resolved
Pressure gauge at fire pump outlet indicated faulty pressure while system de-energized. Replace gauge and demonstrate proper pressure during energized and de-energized states.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2019
Resolved 13 June 2019
Resolution: Resolved same day of inspection.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 June 2019
Resolved
Discovered that the fixed fire suppression system was not annually serviced. Provide service report for proper system servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2019
Resolved 13 June 2019
Resolution: Resolved same day of inspection by Nardini Fire Equipment of Brainerd, MN.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 August 2018
Resolved
Current COD expired July 31, 2018. Renew COD and provide proof of renewal.
Action required: 10 - Deficiency Rectified
Due 27 August 2018
Resolved 27 August 2018
Resolution: Receipt for renewal of COD was provided prior to departing inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 August 2017
Resolved
No night operations until proper repair of mast light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Mast light was corrected during the inspection and is fully operational.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 August 2017
Resolved
Life rings on board need labeled with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 7 September 2017
Resolution: New labels applied.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 August 2017
Resolved
All lifejacket storage must be labeled with contrasting colors 2in. in height.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 7 September 2017
Resolution: New labels applied.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 June 2014
Resolved
120V GFI outlet box located centerline on the upper deck canopy frame needs a water tight fitting installed for the cable penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 17 July 2014
Resolution: Builder corrected
Engineering › Fuel Oil Service System › Hose
Issued 2 June 2014
Resolved
Flexible fuel oil return tines on both MDE's need chaffing gear installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 17 July 2014
Resolution: Builder corrected
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 June 2014
Resolved
Hydraulic and fuel lines in engine room need to be supported with metallic straps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 17 July 2014
Resolution: Installed metallic straps
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 June 2014
Resolved
Vessel has six child size type 1 PFD's onboard and 13 are required.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 19 June 2014
Resolution: Child life jackets installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2014
Resolved
Anchor light is blocked by TV receiver dome and isn't visible from 360*. Light needs to be raised at least 18"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 17 July 2014
Resolution: Builder corrected
Communications › Public Address System › Amplifier
Issued 2 June 2014
Resolved
PA system is not yet operational, technician was working on the system at the time of the inspection.. There is a functioning bullhorn on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 21 June 2014
Resolution: Operational check complete. [name withheld] sent photos of system with power on light
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 June 2014
Resolved
Install and prove proper operation of override switch on the fixed fire protection system automatic shut down.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 20 June 2014
Resolution: System upgraded and operational test sat
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 June 2014
Resolved
Provide complete documentation of enrolment of vessel crew in a random drug testing program. All pre employment testing is to be provided prior to operation.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 18 June 2014
Resolution: All crew members received pre-employment screening and are enrolled in drug testing program