Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Documentation record
Registered dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
ITC tonnagegross 491 / net 147
BuilderBREAUX BROTHERS ENT INC · LOREAUVILLE, LA, UNITED STATES · built 2014
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it491 - Convention (Subpart B), Gross Ton
93 - Regulatory (Subpart C or D), Gross Ton
147 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
27 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8349473
13 April 2026
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8320351
23 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8314540
25 February 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8084179
6 May 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7907287
4 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874090
12 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7667566
18 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7414022
8 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7407820
27 December 2021
Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7372705
10 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7228523
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110179
14 February 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6909431
5 February 2020
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6901660
21 March 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6646798
6 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6350094
24 January 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6342446
27 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6175613
21 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5837762
18 March 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5835814
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 23 February 2026
Resolved
Except as otherwise provided in this section, on a documented vessel, each unlicensed seafarer (seaman) must be: a citizen of the US, an alien lawfully admitted to the US for permanent residence; or a foreign national who is enrolled in the USMMA.
Marine Inspector was notified of 02 non-US resident employed on vessel.
60- Vessel must comply with 46 USC 8103 prior to movement.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 23 March 2026
Resolved 23 February 2026
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 25 February 2025
Resolved
Vessel must comply with the applicable FCC requirements for any installed radio and radar. During blackout drill the vessel's radar and GPS, which supplies position data to DSC radios, were not provided with back-up power. Deficiency rectified.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 February 2025
Resolved 25 February 2025
Resolution: Vsl replaced faulty UPS and retested to the satisfaction of the attending marine inspection.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 February 2025
Resolved
Vessel must comply with the applicable FCC requirements for any installed radio. Vessels single sideband radio was not connected to GPS or programmed with vessel MMSI number for DSC functionality.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2025
Resolved 26 February 2025
Resolution: Vessel rep provided photographic evidence of MMSI programming and GPS data from the chart plotter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 February 2025
Resolved
Vessel shall be ready for inspection of the hull structure and its appurtenances including inspection and operation of all watertight closures in the hull and deck. The cargo area soft patch over the #2 M/E was leaking water into the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 26 February 2025
Resolution: Crew removed old silicone, cleaned the area, reapplied gasket material, and replaced the deck boards.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 April 2023
Resolved
Provisions must be made for closing air supply for a space protected by a fixed gas extinguisher system. Closure devices on deck that do not fully cover openings to the generator room or engine room must be fixed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 13 April 2023
Resolution: Closure covers were fixed and now close vents on-deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 April 2023
Resolved
The construction of a vessel must allow the safe operation giving consideration to provisions for protection against fire. Although fire pump is operable it must be fixed to address water leak of pump shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 13 April 2023
Resolution: Fire pump was rebuilt and tested satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 April 2023
Resolved
The construction of a vessel msut allow the safe operation of the vessel giving special consideration for a seaworthy hull. The weld crack of exhaust pipe overboard outlet, inside machinery space by bowthruster cooling pump #1, must be reparied.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 13 April 2023
Resolution: Cracked weld on exhaust pipe was properly rewelded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 February 2020
Resolved
Two watertight doors were observed not to be watertight by allowing air to pass through. Watertight doors shall be adjusted to prevent any leakage.
Action required: 10 - Deficiency Rectified
Due 2 March 2020
Resolved 18 February 2020
Resolution: Vessel crew adjusted the hatch to prevent any leakage.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 February 2020
Resolved
A Fire hose at the rear engine fire station was unattached with the nozzle tip unattached. Fire hoses with a nozzle must be attached to each fire hydrant at all time.
Action required: 10 - Deficiency Rectified
Due 2 March 2020
Resolved 18 February 2020
Resolution: Vessel crew attached the fire hose to the fire station and attached the nozzle tip.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 February 2020
Resolved
During the fire drill, a fire hose ruptured at the seam. Vessel must have have enough fire stations to reach any part of the vessel using a single length of fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2020
Resolved 18 February 2020
Resolution: Vessel bought new fire hose to replace damaged fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 February 2020
Resolved
The fuel hose on the port generator was observed to be chaffed by the prime mover. The non-metallic fuel hose must be protected from mechanical damage.
Action required: 10 - Deficiency Rectified
Due 2 March 2020
Resolved 18 February 2020
Resolution: Vessel crew placed chaffing protection on fuel hose to prevent futher chaffing and will replace when able.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 27 June 2017
Resolved
Engine room bilge alarm was not working.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 27 June 2017
Resolution: Vessel rep replaced broken wire connection, alarm now operational.