HARMONY OF THE SEAS is a 2016 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2016, most recently in November 2025, along with 13 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 2 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it226963 - Convention (Subpart B), Gross Ton 20236 - Dead Weight, Ton 106042 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 37
2 November 2025COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8259905
11 May 2025PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8126824
9 November 2024PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8029761
7 September 2024Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8007771
12 May 2024COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7908162
12 November 2023PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7821858
1 October 2023In-Service Inspection · Administrative Inspection
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 November 2024Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, except those for emergency escape trunks, shall be capable of remote release from the continuously manned central control station, either siultaneously or in groups, and shall be capable of release also individually froma position at both sides of the doors. Release switches shall have an on-off function to prevent automatic resetting of the system. PSCO observed that the release switches from both sides of the galley boundry fire door 08-5-04 were inoperable due to error code in the controller.
Reculatory Cite 74 SOLAS 20 II-2/9.4.1.1.5.3
action 16ac and then cleared on spot
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2024
Resolved 9 November 2024
Resolution: ships crew found the error code in the controller and reset cleared on the spot
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel suffered a loss of remote control steering from the bridge.
74 SOLAS (20) Ch. II-I Reg. 31.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 October 2023
Resolution: Received Class survey and confirmation from flag administration that all azipods and remote steering capabilities are fully functional.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 November 2022Resolved
Escape door from public spaces that are normally latched shall be fitted with means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. PSCO's observed the primary means of escape in the Coastal Kitchen was only able to be opened by pressing a button on the side wall and not in the direction of escape causing the door to not have a means of quick release.
74SOLAS(20) II-2/13
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 November 2022
Resolved 12 November 2022
Resolution: Locking mechanism for the restaurant doors were disabled and doors will be kept open during the restaurants operating hours on the ship. Approved by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 November 2022Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO's observed that lifeboat 17 with a crack in the port quarter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 November 2022
Resolved 12 November 2022
Resolution: Fiberglass was repaired onboard to the satisfactory of class
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2021Resolved
Fire Doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the requirements in this regulations 9.1 through .15). PSCOs observed FD-12-6-11, a sliding fire screen door in a main vertical zone not operating as designed. SOLAS 20 II-2/9.4.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2021
Resolved 10 December 2021
Resolution: Class (DNV) provided documentation attesting to proper operation of FSD 12-6-11. Deficiency rectifed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2019Resolved
07105 - Fire Safety - Fire doors in MVZ bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following: The door shall be self-closing. The following FSD's did not close and latch appropriately: FSD 08-4-03, FSD 02-7-14, FSD 02-7-05 - 74 SOLAS 2014 Cons. II-2/ 9.4.1.1.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 October 2019
Resolved 13 October 2019
Resolution: FSD's were corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 October 2019Resolved
07120 - Fire Safety - Escape Routes shall be maintained in a safe condition and clear of obstacles. FSD 3-7-5 was locked and the thumb latch was removed, rendering door unable to be opened - 74 SOLAS 2014 Cons. II-2/13.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 October 2019
Resolved 13 October 2019
Resolution: Locking mechanism was replaced with an appropriate thumb latch, and FSD was able to be opened from both sides.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2019Resolved
07105 - Fire Safety - Fire doors in MVZ bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following: The door shall be self-closing. The following FSD's shall be self-closing: FSD 02-3-13 was blocked and unable to self-close - 74 SOLAS 1014 Cons. II-2/9.4.1.1.5
Action required: 10 - Deficiency Rectified
Due 13 October 2019
Resolved 13 October 2019
Resolution: The cart blocking the FSD was moved out of the way, which allowed the FSD to be closed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2019Resolved
07103 - Fire Safety - Where "A" Class Divisions are penetrated, such penetrations shall be suitably insulted. Two wires were found by PSCO's in the back stage theater alleyway penetrating an "A" Class boundary which were not properly insulted. - 74 SOLAS 2014 Cons. II-2/9.3
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 November 2019
Resolved 20 October 2019
Resolution: Vessel provided pictures and class documentation attesting to satisfactory repairs to the Class A boundary.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2018Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat #9 was not ready for immediate use. Propulsion was inoperable. Propeller would not engage forward or reverse. In addition, lifeboat #3's electronics were inoperable.
74 SOLAS (2014) III/20.2
Action required: 10 - Deficiency Rectified
Due 20 October 2018
Resolved 20 October 2018
Resolution: Lifeboat issues were corrected by the end of the exam.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 October 2018Resolved
The public address system shall be clearly audible above the ambient noise in all spaces. Star Wars arcade game on deck 15 did not silence during public address announcement.
74 SOLAS (2014) III/6.5.2.
Action required: 10 - Deficiency Rectified
Due 20 October 2018
Resolved 20 October 2018
Resolution: Video game and public address system were arranged to shut off the video game's noise during PA announcements before the completion of the exam.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 October 2018Resolved
Every crewmember with emergency duties shall be familiar with these duties before the voyage begins. Stairway guides in forward stairwell deck 03 and crewmembers of starboard side lifeboats are unfamiliar with muster station locations.
74 SOLAS (2014) III/19.2.1.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 October 2018
Resolution: Class Report sent in attesting to the training. All defs Cleared.
Engineering › Non-conventional Propulsion/Steering › Electric Motor (Azipod)
Issued 17 February 2017Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons onboard. The port azipod propulsion unit cannot be controlled locally or from the bridge. 74 SOLAS (14 cons)ch 1/reg 11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2017
Resolution: Received class report attesting to the successful sea trial of the port pod.