LENA

LENA is a freight ship. The Coast Guard has recorded 31 inspections since 2016, most recently in April 2026, along with 32 deficiencies and 8 operational controls.

Records from 2016 to 2026. Most recent: inspection, 12 April 2026.

Built
Not recorded
Last inspected
12 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9347750
1272183
Flag
CYPRUS
Maury page id
psix-1272183

Documentation record

Tonnage as PSIX records it16809 - Displacement, Ton
4900 - Convention (Subpart B), Net Ton
11227 - Dead Weight, Ton
9981 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

12 April 2026 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8346552
20 March 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8329283
2 March 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8318970
12 February 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8309652
18 January 2026 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8297908
9 August 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8199996
31 January 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8072647
15 January 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8064041
11 July 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7952967
18 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7897477
12 October 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7803240
19 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7653030
27 February 2023 Administrative Inspection · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7642386
11 August 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7530534
23 January 2022 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384249
19 July 2021 Administrative Inspection · Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7261363
16 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7263027
1 October 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7066626
25 June 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6725567
14 April 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6682364
7 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6657946
27 March 2019 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6648943
12 March 2019 NPV Safety Exam · In-Service Inspection · Administrative Inspection · ISPS III Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6641493
18 August 2018 Ballast Water Examination · Administrative Inspection · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6515665
23 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6311816
23 November 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6311932
18 September 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6269529
30 August 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6255360
15 August 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6241441
30 August 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5987481
2 August 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5960276

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 January 2025 Resolved
PURPOSE OF REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. THE FOLLOW FUNCTIONAL REQUIREMENTS SHALL BE MET. PSCO OBSERVED SEVERAL RAGS UNDER AND SOAKED RAGS POOLED COLLECTING UNDER AUX 1 MDE. MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUID.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
Resolution: class survey submitted/reviewed attesting to rectifying deficiency. survey to be uploaded 1/17
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 25 June 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2019
Resolved 27 June 2019
Resolution: New 2nd engineer brought on board.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 March 2019 Resolved
01-15109-OBJECTIVE EVIDENCE DISCOVERED DURING AN EXPANDED ISM EXAMINATION REVEALED THE VESSEL FAILED TO FULLY IMPLEMENT THE REQUIREMENTS OF THE ISM CODE THROUGH THEIR SAFETY MANAGEMENT SYSTEM (SMS) AS EVIDENT IN THE IDENTIFIED MAJOR NON-CONFORMITIES LISTED IN THE DEFICIENCIES. AN EXTERNAL AUDIT IS RECOMMENDED. 74SOLAS(14CONS)CH IX/ REG 3.1 ISM CODE PART A 1.3 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: SMS Audit was completed on 17MAR19 as per CG request addressing all major deficiencies presented during the detention.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 March 2019 Resolved
03-11104-RESCUE BOAT SHALL BE STOWED IN A STATE OF CONTINUOUS READINESS. PSCO OBSERVED RESCUE BOAT WAS UNABLE TO START DUE TO BATTERY NOT BEING CHARGED. 74SOLAS(14CONS) CH III/ REG 14.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: Attended vessel on 18MAR19 to verify deficiency was rectified to the satisfaction of the CG. Received class report stating 2 new batteries were installed. Engine test and found in order.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 13 March 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: CG Attended vessel on 18MAR19 to verify deficiency was rectified. Receieved class report stating quick closing valves for 1 & 2 ship service generators were repaired and tested.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 March 2019 Resolved
05-07126-MEANS SHALL BE PROVIDED TO CONTROL THE LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED LUBE OIL POOLED UNDER AND AROUND BOTH SHIP SERVICE DIESEL GENERATORS IN EXCESS OF FIVE GALLONS. LUBE OIL, FUEL OIL, AND WATER WAS POOLED AND COATED THE ENGINE ROOM'S BILGE WELL AND BILGE WELL'S WALLS. ADDITIONALLY, LUBE AND FUEL OIL WAS POOLED UNDER AND AROUND THE OILY WATER SEPARATOR CREATING A FIRE HAZARD. 74SOLAS(14CONS)CH II-II/ REG 4.1.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 14 April 2019
Resolution: Oil was removed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2019 Resolved
06-07110-TWO SPARE CHARGES SHALL BE PROVIDED FOR EACH REQUIRED BREATHING APPARATUS. THE VESSEL'S FIRE PLAN REQUIRES FOUR FIREFIGHTING ENSEMBLES TO INCLUDE A SELF-CONTAINED BREATHING APPARATUS FOR EACH. ADDITIONALLY, THE VESSEL HOLDS A DANGEROUS GOODS DOCUMENT OF COMPLIANCE REQUIRING TWO ADDITIONAL SELF-CONTAINED BREATHING APPARATUSES. THEREFORE, THE VESSEL IS REQUIRED 18 TOTAL SELF-CONTAINED BREATHING APPARATUS BOTTLES ON BOARD. THE VESSEL HAD NINE TOTAL SELF-CONTAINED BREATHING APPARATUS BOTTLES ON BOARD. 74SOLAS(14CONS)CH II-II/ REG 10.2.5 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: CG attended vessel on 18MAR19 to clear deficicency. Receieved class report stating 12 spare cylinders were provided and distributed in different locations of fire fighters equipment.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 13 March 2019 Resolved
10-10103-ALL SHIPS OF 300 GROSS TONNAGE AND UPWARDS SHALL BE FITTED WITH 9GHZ RADAR. PSCO OBSERVED SHIP'S 9GHZ RADAR WAS NOT OPERABLE. 74SOLAS(14CONS)CH V/ REG 19.2.3.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel on 18MAR19 to verify deficiency was rectified. Received class survey stating Mackay Marine Technician boarded vessel, examined radar and replaced magnetron.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 13 March 2019 Resolved
26-10114- THE ADMINISTRATION SHALL BE SATISFIED THAT ADEQUATE ARRANGEMENTS ARE IN PLACE TO ENSURE THAT THE PERFORMANCE OF THE EQUIPMENT REQUIRED BY THIS CHAPTER IS MAINTAINED. PSCO OBSERVED THAT ONE OF THE SECURING STRAPS ON THE VOYAGE DATA RECORDER WAS MISSING AND THE OTHER WAS SEVERELY CORRODED CAUSING IT TO BE INADEQUATELY SECURED. 74SOLAS(14CONS)CH V/ REG 16.1 17AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel on 18MAR19 and cleared deficiency. Class report states security straps for the VDR was reinstalled, examined and found in order.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 March 2019 Resolved
07 - 07123 A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM SHALL BE OF AN APPROVED TYPE AND COMPLY WITH THE FIRE SYSTEM SAFETY CODE. PSCO OBSERVED PLASTIC COVERING THE SMOKE DETECTOR IN THE ENGINE ROOM ABOVE THE BOILER'S EXHAUST LEAK. 74SOLAS(14CONS)CH II-II/ REG 4.2.2 30ABC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel on 18MAR19 clearing deficiency. Received class report stating plastic wrap was removed from the smoke detector above the boiler's exhaust leak.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 March 2019 Resolved
09-13199-MEANS SHALL BE PROVIDED TO CONTROL THE LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED CREW FABRICATED CATCH PANS FILLED WITH A LUBE OIL / FUEL OIL MIXTURE UNDER EACH CRANK CASE EXPLOSION COVER ON THE MAIN ENGINE HOLDING UP TO ONE GALLON. 74SOLAS(14CONS)CH II-2 / REG 4.1.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: Class report states main engine leaks from crankcase explosion covers were re-tightened, tested, and no leaks were observed. CG reboarded vessel and cleared deficiency on 18MAR19
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
11-13199-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED THE TECHNICAL WATER LINE HAD 7 SOFT PATCHES INSTALLED ON THE FIXED PIPING. 74SOLAS(14CONS)CH I/ REG 11 17AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 7 April 2019
Resolution: Soft patches replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
12-13199-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP AND THE PERSONS ONBOARD. PSCO OBSERVED A FIBERGLASS PATCH ON THE COOLING WATER PRESSURE RELIEF VALVE FOR THE FUEL OIL PURIFIER. 74SOLAS(14CONS) CH I/ REG 11 17AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 7 April 2019
Resolution: Fiberglass patch replaced with new piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
13-13199-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP AND THE PERSONS ONBOARD. PSCO OBSERVED A SOFT PATCH ON THE OILY WATER SEPARATOR SUCTION LINE FROM THE BILGE TANK. 74SOLAS(14CONS)CH I/ REG 11 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel and cleared deficiency. Received class report stating soft patch was removed from OWS bilge suction line. Suction line was tested and found in order.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2019 Resolved
14-07110-THE FIREFIGHTERS OUTFITS AND PERSONAL PROTECTION EQUIPMENT SHALL BE KEPT READY FOR USE, IN AN EASILY ACCESSIBLE LOCATION MARKED AND, WHERE MORE THAN ONE FIREFIGHTERS OUTFIGHT OR MORE THAN ONE SET OF PERSONAL EQUIPMENT IS CARRIED, THEY SHALL BE STORED IN WIDELY SEPARATED POSITIONS. PSCO OBSERVED FIREFIGHTERS OUTFITS THAT WERE NOT KEPT READY FOR USE NOR CLEARLY MARKED, ADDITIONALLY THEY WERE STORED IN SAME LOCATION. 74SOLAS(14CONS)CH II-II/ REG 10.3.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating fire fighter's outfits are marked and distributed according to the fire control plan.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 March 2019 Resolved
15-071222-GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP'S OFFICERS, SHOWING CLEARLY FOR EACH DECK THE FIRE-EXTINGUISHING APPLIANCES. PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE; ANY ALTERATIONS THERE TO SHALL BE RECORDED AS SOON AS PRACTICABLE. PSCO OBSERVED FIREFIGHTING EQUIPMENT WAS NOT STOWED ACCORDING TO FIRE CONTROL PLAN. 74SOLAS(14CONS)CH II-II/ REG 15.2.4.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2019
Resolution: CG attended vessel and cleared deficiency. Received class report stating fire fighting equipment is stored as indicated on the fire control plan.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 13 March 2019 Resolved
16-13199-EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERE TO THROUGH WHICH STEAM MAY PASS MAY BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. PSCO OBSERVED A STEAM LEAK IN THE VICINITY OF THE BOILER AND IN THE BILGE NEAR THE HEAVY FUEL OIL TANK. 74SOLAS(04CONS)CH II-I/ REG 33.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Class report states steam pipe leaks in the vicinity of the auxiliary boiler & heavy fuel oil tank were corrected, examined, and found in order. CG attended vessel on 18MAR19 and cleared deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 March 2019 Resolved
17-09298-THE MACHINERY AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED MULTIPLE LOCATIONS THROUGHOUT ENGINE ROOM WHERE WELDS CONNECTING SAFETY RAILS TO FLOOR WERE BROKEN. 74SOLAS(04CONS)CH II-I/ REG 26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating engine room safety rails were repaired and examined to the satisfaction of DNV-GL. CG attended vessel on 18MAR19 and cleared deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 March 2019 Resolved
18-09208- THE MACHINERY SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND HAZARDS. PSCO OBSERVED TWO GENERAL SERVICE PUMPS MISSING PROTECTIVE SHIELDS. 74SOLAS(04CONS)CH II-I/REG 26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating protective covers for general service pumps 1 & 2 were reinstalled and found in order to the satisfaction of DNV-GL. CG attended vessel on 18MAR19 and cleared deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
19-13199-THE MACHINERY SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND HAZARDS. PSCO OBSERVED EXHAUST GASES LEAKING FROM THE #2 SHIP SERVICE DIESEL GENERATOR. IT WAS ALSO EVIDENT THAT EXHAUST LEAKS WERE PRESENT ON THE MAIN ENGINE AND BOILER. . 74SOLAS(04CONS)CH II-I/REG 26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating exhaust gas compensator for service diesel generator was renewed. Engine was tested and no leaks were observed. Exhaust gas leaks noted on the main engine and boiler were reported to be old and already repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2019 Resolved
20-09209-CABLES AND WIRING SHALL BE INSTALLED AND SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFING OR OTHER DAMAGE. PSCO OBSERVED CABLE RUNGS HELD IN PLACE WITH RAGS IN ENGINE ROOM. 74SOLAS(04CONS)CH II-I/REG 45.5.5 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Class report states cables in steering engine room secured using standard practice applied to the system. Examined and found in order by DNV-GL and CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019 Resolved
21-13199-LUBE OIL PIPES SHALL BE OF STEEL OR OTHER APPROVED MATERIAL, EXCEPT THAT RESTRICTED USE OF FLEXIBLE PIPES SHALL BE PERMISSIBLE IN POSITIONS WHERE THE ADMINISTRATION IS SATISFIED THEY ARE NECESSARY. PSCO OBSERVED PNEUMATIC PUMP WITH ATTACHED FLEXIBLE PIPES USED FOR THE TRANSFERRING BETWEEN LEAK OIL AND SLUDGE TANK. THIS ARRANGEMENT WAS NOT APPROVED BY VESSEL'S CLASS OR FLAG STATE.. 74SOLAS(14CONS)CH II-II/ REG 4.2.3.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating connection between leak oil and sludge tank was removed. Pneumatic pump removed and stored. CG attended vessel 18MAR19 and cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 13 March 2019 Resolved
22-07118-SHIP'S 500 GROSS TONNAGE AND UPWARDS SHALL BE PROVIDED WITH AT LEAST ONE INTERNATIONAL SHORE CONNECTIONS COMPLYING WITH THE FIRE SAFETY SYSTEMS CODE. PSCO OBSERVED BOLTS MISSING FROM INTERNATIONAL SHORE CONNECTION. . 74SOLAS(14CONS)CH II-II/ REG 10.2.1.7.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Receieved class report stating international shore connection has corresponding bolts, nuts, gasket and is properly secured in the front bulkhead of the accomodations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 March 2019 Resolved
23-13102-OIL FUEL PIPES AND THEIR VALVES AND FITTINGS SHALL BE OF STEEL OR OTHER APPROVED MATERIAL EXCEPT THAT RESTRICTED USE OF FLEXIBLE PIPES SHALL BE PERMISSIBLE IN POSITIONS WHERE THE ADMINISTRATION IS SATISFIED THAT THEY ARE NECESSARY. SUCH FLEXIBLE PIPES AND END ATTACHMENTS SHALL BE OF APPROVED FIRE-RESISTING MATERIALS OF ADEQUATE STRENGTH AND SHALL BE CONSTRUCTED TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED SOFT PATCH ON FUEL LINE GOING FROM EMERGENCY GENERATOR DIESEL OIL TANK TO THE EMERGENCY GENERATOR. 74SOLAS(14CONS)CH II-II/ REG 4.2.2.5.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel and cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 March 2019 Resolved
24 - 07111- FIREFIGHTER'S OUTFIT SHALL COMPLY WITH THE FIRE SAFETY SYSTEM CODE. PSCO OBSERVED FIREFIGHTER'S OUTFIT WAS DAMAGED AND PROTECTIVE COATING WAS MISSING. 74SOLAS(14CONS)CH II-II/ REG 10.2.1 FSS COCE 3.2.1.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: CG attended vessel on 18MAR19 and cleared deficiency. Received class report stating fire fighter's outfit was renewed and placed in the corresonding locker.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 March 2019 Resolved
25-09206-THE OPENING BELOW THE LOWEST COURSE OF THE GUARD RAILS SHALL NOT EXCEED 230 MM. THE OTHER COURSES SHALL BE NOT MORE THAN 380 MM APART. PSCO OBSERVED HAND RAIL ON DECK WITH A LOWER BROKEN RUNG. ICLL ANNEX 1/REG 25.3 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received class report stating guard rails were repaired and examined to the satisfaction of DNV-GL.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 March 2019 Resolved
2 - 15109 THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS. IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT; ANY NON-CONFORMITY IS REPORTED; AND APPROPRIATE CORRECTIVE ACTION IS TAKEN. THE VESSEL’S ONBOARD SAFETY MANAGEMENT SYSTEM STATES THAT A NON-CONFORMITY SHOULD BE REPORTED “IF OBJECTIVE EVIDENCE INDICATES THAT A PROCEDURE WAS NOT FOLLOWED”. PSCO OBSERVED MULTIPLE SITUATIONS WHERE A NON-CONFORMITY SHOULD HAVE BEEN REPORTED TO THE COMPANY IN ACCORDANCE WITH THE “NONCONFORMITIES CORRECTIVE ACTION” PROCEDURES (MSD-18-330) AS EVIDENCED BY THE FOLLOWING: RESCUE BOAT NOT ABLE TO START DUE TO DEAD BATTERY, QUICK CLOSING VALVES ON DIESEL GENERATOR’S FUEL SYSTEM MODIFIED TO REMAIN OPEN, FUEL OIL AND LUBE OIL LEAKS THROUGHOUT THE ENGINE ROOM, A SOFT PATCH ON EMERGENCY DIESEL GENERATOR FUEL LINE, INADEQUATE FIRE FIGHTNING EQUIPMENT, AND SMOKE DETECTION ON THE BOILER FLAT WAS INTENTIONALLY BLOCKED BY A PLASTIC COVER. THERE WERE NO NONCONFORMITIES ISSUED TO THE COMPANY FOR THESE CONDITIONS. 74SOLAS (14CONS)CH IX/ REG 3.1 ISM CODE PART A 6.2 ISM CODE PART A 10.2.2 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: SMS Audit was completed on 17MAR19 as per CG request addressing all major deficiencies presented during the detention.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 12 March 2019 Resolved
08-15101-ENTRY INTO AN ENCLOSED SPACE SHOULD BE PLANNED OUT AND THE USE OF AN ENTRY PERMIT SYSTEM IS RECOMMENDED. AN ENCLOSED SPACE ENTRY PERMIT SHOULD BE ISSUED BY THE MASTER OR A NOMINATED RESPONSIBLE PERSON AND COMPLETED PRIOR TO ENTRY INTO THE SPACE. THE VESSEL'S SAFETY MANAGEMENT SYSTEM (MSD-51-360) STATES THAT THE MASTER SHALL ENSURE THAT FOR ALL ENTRIES INTO ENCLOSED SPACES, AN ENCLOSED SPACE ENTRY PERMIT (MSD-51-360F1) IS COMPLETED AND FILED. PSCO IDENTIFIED THAT THE ELECTRICIAN ENTERED THROUGH A MANHOLE TO A FORWARD BILGE WELL PIPING TRUNK ON 9MAR19 TO CONDUCT MAINTENANCE. AN ENCLOSED SPACE ENTRY PERMIT (MSD-51-360F1) WAS NOT COMPLETED. 74SOLAS(14CONS)CH III/REG19.4.2.5 IMO RES. 1050(27) ISM CODE PART 1/1.4 30ABC
Action required: 30 - Ship detained
Resolved 18 March 2019
Resolution: SMS Audit was completed on 17MAR19 as per CG request addressing all major deficiencies presented during the detention. CG reboarded vessel on 18MAR19 and cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 August 2018 Resolved
SOLAS 74 (14 CONS) II-2/ 9.7.2.2.1.2..Automatic fire dampers are fitted close to the boundaries penetrated. PSCO oberved automatic fire damper ventilation in emergency generator space unable to close automatically.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2018
Resolved 19 August 2018
Resolution: Vessel sent in photos of a new fire hydrant valve that was replaced and operated successfully without leaking. Photos of the valve and test attached to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 August 2018 Resolved
SOLAS7(14CONS) III/34 LSA CODE 4.1.6.3.2 Hydrostatic release unit...shall automatically release the liferaft. PSCO observed liferaft on stbd side with hydrostatic release installed to weak link which would cause the liferaft to release without inflating.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 August 2018
Resolved 19 August 2018
Resolution: HRU re-installed properly IAW manufacturers instructions.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 August 2018 Resolved
Solas 74(14CONS) II-2/10.2.1.4.2. A valve shall be fitted to serve each fire hydrant.. PSCO observed leaking valve at fire station STBD side, main deck, just FWD of the superstructure.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2018
Resolution: Vessel sent in photos of a new fire hydrant valve that was replaced and operated successfully without leaking. Photos of the valve and test attached to documents.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 August 2017 Resolved
0999- Fire Fighting - The Purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be maintained at openings and penetrations. Class A boundaries separation main engine space and steering space has open 1.5 diameter circular penetration. 74solas(2014) II-2/9.3 40ac
Action required: 15 - Rectify deficiencies by next port
Due 16 August 2017
Resolved 30 August 2017
Resolution: The penetration was repaired by welding a new piece of steel over it, sanded, and painted. No further deficiencies were found during the time of the inspection. Class was sheduled to attend the vessel later in the day on 30AUG17

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.