SARI INDAH

SARI INDAH is a 2013 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in August 2022, along with 6 deficiencies and 8 operational controls.

Records from 2016 to 2022. Most recent: inspection, 16 August 2022.

Built
2013
Last inspected
16 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 August 2022
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9624964
9V2273
1272216
Flag
SINGAPORE
Maury page id
psix-1272216

Documentation record

Tonnage as PSIX records it87193 - Dead Weight, Metric Ton
48065 - Convention (Subpart B), Gross Ton
27700 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

16 August 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7517827
2 August 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7522777
28 July 2022 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7518702
19 March 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6918373
6 March 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6921949
6 May 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6678458
27 April 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6662058
21 April 2019 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6666830
19 June 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6152606
2 March 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097928
2 March 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6099643
25 March 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5832146

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 August 2022 Resolved
07126 - THE PURPOSE OF THIS REGUALTION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL OIL ACCUMULATED ON THE #2 AND THE #5 FUEL PUMP FOR THE MAIN DIESEL ENGINE. PSCO ALSO OBSERVED ACCUMULATED OIL BENEATH GRATING BETWEEN THE #2 AND #3 GENERATORS. 74 SOLAS (20) CHAPTER II-2 REG 4.1.1 / 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2022
Resolution: Recieved, reviewed and accepted a class report from Lloyd's Register verifying the rectification of deficiency. Fuel pump replaced on MDE, fuel line replaced on #3 SSDG
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 April 2019 Resolved
1. 07109- (FIXED FIRE EXTINGUISHING INSTALLATION)- 1. 07109- (FIXED FIRE EXTINGUISHING INSTALLATION)- FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. THE FIXED C02 FIRE-FIGHTING SYSTEM WAS FOUND WITH A BRANCH LINE NOT CONNECTED TO A C02 BOTTLE TO THE DISCHARGE MANIFOLD AND SEVERAL PLACES WHERE THE BRANCH LINES WERE CHAFFED WITH WIRE BRADING EXPOSED. 74SOLAS(14) II-2/14.2.1.2 30ac
Action required: 30 - Ship detained
Resolved 29 April 2019
Resolution: Received, reviewed and accepted class report / proper documentation from LR stating the deficiency was rectified. Branch lines were replaced with vessel's spares and considered satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 April 2019 Resolved
2. 15109- (MAINTENACE OF THE SHIP AND EQUIPMENT)- THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. OBJECTIVE EVIDENCE DURING AN EXPANDED ISM EXAM REVEALED THAT THE CREW WAS NOT ACCURATELY FOLLOWING THE SHIP’S PROCEDURES WITH REGARD TO THE INSPECTION OF THE C02 BOTTLE STORAGE ROOM. IT IS RECOMMENDED THAT AN EXTERNAL THIRD PARTY AUDIT OF THE SMS BE CONDUCTED WITH REGARD TO DEFICIENCY NO. 1. 74 SOLAS (14) IX/ 3.1, ISM CODE PART A 10.1- 30ac AFTER ISSUANCE OF DEFICIENCY CLASS ATTENDED VESSEL AND REQUIRED AN ISM AUDIT WITHIN 90 DAYS. DEFICIENCY WAS CHANGED FROM AN ACTION CODE OF 30 TO 40 TO ENSURE THE PROPER ACTIONS ARE TAKEN PRIOR TO THE VESSELS RETURN TO THE U.S.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2019 Resolved
3. 13199- (OTHER (MACHINERY))- THE MACHINERY BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. A STEAM HEATING PIPE FOR THE FUEL STORAGE SYSTEM ON DECK, BETWEEN CARGO HOLDS 3 AND 4 WAS FOUND CORRODED AND LEAKING. 74SOLAS(14) II-1/26.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2019
Resolved 29 April 2019
Resolution: Received, reviewed and accepted class report / proper documentation from LR stating the deficiency was rectified. A temporary repair was made by welding with a condition of class requirement for permanent repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2019 Resolved
4. 13199- (OTHER (MACHINERY))- THE MACHINERY BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. A VALVE IN A STEAM TRACING LINE FOR FUEL OIL DAY TANKS WAS FOUND TO BE LEAKING AND DEGRADED THE INTEGRITY OF THE VALVE. 74SOLAS(14) II-1/26.1 10c
Action required: 10 - Deficiency Rectified
Resolved 27 April 2019
Resolution: RECTIFIED IN FRONT OF COAST GUARD PSCO.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 19 June 2017 Resolved
0725-(Fire fighting equipment-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO discovered the main hypermist system control panel in the engine room set to the manual mode. Vessel has a periodically unattended machinery space and system has been in manual mode for the duration of the vessel's last voyage.SOLAS(14)II-2/14.2 30c
Due 19 June 2017
Resolved 19 June 2017
Resolution: Switch on main hypermist system control panel was set to automatic.