← All vessels
MAERSK MONTE OLIVIA
MAERSK MONTE OLIVIA is a 2004 freight ship. The Coast Guard has recorded 22 inspections since 2014, most recently in December 2025, along with 8 deficiencies and 2 operational controls.
Records from 2014 to 2025. Most recent: inspection, 1 December 2025.
- Built
- 2004
- Last inspected
- 1 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9283198 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6839
1272324
Flag
SINGAPORE
—
Maury page id
psix-1272324
Inspections, by type
…with no type recorded3
Years with a record
9 calendar years (2014–2025)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it95156 - Displacement, Metric Ton
71273 - Dead Weight, Metric Ton
69132 - Convention (Subpart B), Gross Ton
34823 - Convention (Subpart B), Net Ton
71273 - Dead Weight, Metric Ton
69132 - Convention (Subpart B), Gross Ton
34823 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
1 December 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8275364
27 July 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7964478
14 July 2024
In-Service Inspection · MARPOL Annex VI Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7957866
17 May 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7914383
28 April 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7902758
26 March 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7885017
19 September 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7793525
30 July 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7755841
30 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7756374
30 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7822770
14 February 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636416
30 December 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7614597
3 August 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7523272
16 January 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7381068
24 March 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6647988
8 February 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6622304
29 October 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6576403
29 May 2018
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6427324
2 January 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6331210
6 December 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6053258
9 November 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5759936
13 October 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5000607
Deficiency record · 8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 May 2024
Resolved
A main source of electrical power of sufficient capacity to supply all those swervices mentioned in regulation 40.1.1 shall be provided. PSCDO was notified that vessel had a blackout and lost power to 01 of the auxillary engines while making preparations to get underway. (74 SOLAS (20) II-1/41.1.1)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 26 March 2024
Resolved
THE COMPANY IS RESPONSIBLE FOR ENSURING THAT ADEQUATE RESOURCES AND SHORE-BASED SUPPORT ARE PROVIDED TO ENABLE THE DESIGNATED PERSON OR PERSONS TO ARRAY OUT THEIR FUNCTIONS. THE SHIP HAS NOT BEEN PROVIDED NECESSARY RESOURCES FOR THE MAINTENANCE AND UPKEEP OF LAGGING THROUGHOUT THE ENGINE ROOM. THE COMPANY HAS BEEN AWARE OF THE ISSUE SINCE SEP23.
74SOLAS(20)IX/3.1 // ISM CODE PART A/3.3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2024
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL SOAKED LAGGING THROUGHOUT THE ENGINE ROOM.
74SOLAS(20)II-2/4.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 26 March 2024
Resolved
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS... [name withheld] OF CONDENSATION PIPELINE FROM HEAT TRACING LINE IN ENGINE ROOM WITH A RATE OF ONE DROP EVERY FIVE SECONDS.
74SOLAS(20)I/11(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 December 2022
Resolved
The condition of its ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The pilot reported that while heading outbound Delaware Bay, DE, the vessel experienced a loss propulsion after generators tripped off-line, which caused the main engine to lose power completely. Due to not having full vessel maneuverability, the pilot anchored the vessel at Breakwater Anchorage. Prior to movement of the vessel, a causal analysis must be conducted and proper repairs completed, if needed. Coast Guard requires a class report to verify that the deficiency is fully rectified and that vessel is safe to proceed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 February 2019
Resolved
Before the ship leaves port, all life saving appliances shall be in working order and ready for immediate use.
Liferaft painter was unable to reach hydrostatic release. Crew repositioned hydrostatic release so painter was able to be properly connected.
SOLAS (14) III/20.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2019
Resolved
Machinery and fittings shall be adequate for service. They are intended to be installed as they reduce any danger on board.
Boiler receiver supply pump was found with a steady drip of oil.
SOLAS (04) II-1/26.1
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 13 October 2014
Resolved
1499 - The emerency generator shall have the capability of a secondary means of starting. The second starting device(hydralic hand pump is non operational. 74 SOLAS II-1/44.2 - 16AC - Vessl has a flag dispensation requiring repairs prior to 31OCT14.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.