← All vessels
MAERSK MONTE ALEGRE
MAERSK MONTE ALEGRE is a 2008 freight ship. The Coast Guard has recorded 14 inspections since 2015, most recently in February 2026, along with 7 deficiencies and 1 operational control.
Records from 2015 to 2026. Most recent: inspection, 4 February 2026.
- Built
- 2008
- Last inspected
- 4 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9348065 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
S6BH
1272346
Flag
SINGAPORE
—
Maury page id
psix-1272346
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2015–2026)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it107340 - Displacement, Metric Ton
83440 - Dead Weight, Metric Ton
69132 - Convention (Subpart B), Gross Ton
42020 - Convention (Subpart B), Net Ton
83440 - Dead Weight, Metric Ton
69132 - Convention (Subpart B), Gross Ton
42020 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
4 February 2026
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8305105
15 October 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8251782
10 April 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8109612
4 April 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8104928
4 April 2025
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8105266
7 November 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8031510
13 August 2024
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7980427
31 July 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7971880
11 April 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893288
10 June 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7710650
6 June 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704535
26 January 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7385817
28 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5841742
27 July 2015
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5197541
Deficiency record · 7
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 February 2026
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective.
While testing the emergency generator the secondary battery set failed to start. Crew replaced secondary battery, PSCO tested both means of start after the replacement. Both starts satisfactory.
74 SOLAS (04) II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 April 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed oily rags on generator number 2.
74SOLAS (09)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 November 2024
Resolved
(1) Means shall be provided to control leaks of flammable liquids, and the ignitability of combustable materials shall be restricted. PSCO observed multiple oil filled catch basins under service generators # 1,2,&3. PSCO also observed multiple oil soaked rags around service generators. (74SOLAS(04)11-2/4.1.1&.3)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2024
Resolved
(2) After any survey of the ship has been completed. no change shall be made in the machinery, without the sanction of the administration. PSCO observed multiple flex tubing from service generators leading to sludge tanks.
(74SOLAS(20)1/11(B))
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2024
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended... Vessel self-reported their fuel-oil pump on cylinder #3 of their main engine was causing a cut-out. In response the vessel has taken the cylinder out of service and have 7 out of 8 cylinders currently operating.
74 SOLAS (09) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2024
Resolved
Fixed local application fire-extinguishing systems are to protect areas such as the following without the necessity of engine shutdown, personnel evacuation, or sealing of the spaces: Purifiers for heated oil. Vessel reported that their water-mist system had a leak of 50 liters per hour due to damaged solenoid valve. In response, vessel isolated the purifier room from the water mist system to secure the leak.
74 SOLAS (09) II-2/10.5.6.3.4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2024
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended... Vessel self-reported their fuel-oil pump on cylinder #3 of their main engine was causing a cut-out. In response the vessel has taken the cylinder out of service and have 7 out of 8 cylinders currently operating.
74 SOLAS (09) II-1/26.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.