Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD Shipyard LLC · AMELIA, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton 1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 July 2023Resolved
46 CFR 151.04-05 (i)
Safety relief valves shall be tested by bench testing or other suitable means. The valves shall relieve and reseat within the design tolerances of the set pressure, or it shall be removed and reset prior to being returned to service. This test shall be conducted at the time of the inspection for certification.
Marine Inspectors observed no inspection tags attesting to when valves were serviced on either the Safety Relief Valve or the Slop Tank P/V valve. Valves shall be properly serviced and reinstalled on the barge prior to offload of cargo.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 3 August 2023
Resolution: Bench tests completed on relief valves.
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 19 August 2022Resolved
Each vessel that is constructed or adapted to carry , or that carries, oil in bulk as cargo oil cargo residue...must have a valid Vessel Response Plan.
Vessel does not have a valid VRP. Vessel is not authorized to carry oil as cargo or oil residue until a valid VRP is produced.
Action required: 705 - Other - as specified
Resolved 9 January 2023
Resolution: Vessel's CAA has been updated to exclude any cargoes which require approved VRP or SOPEP.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 August 2022Resolved
Pressure vacuum relief valves shall be examined to determine that the operating mechanism is free and capable of activations ... this test shall be conducted at the time of the inspection for certification.
Vessel's pressure vacuum valve was last serviced in September 2016. Valve shall be properly serviced and reinstalled on the barge prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2022
Resolution: Pressure vaccuum valve was removed from the barge and serviced. After servicing it was reinstalled satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2021Resolved
All electrical installations in hazardous locations must comply with the general requirements of IEEE 45. Noted that 3S high/overfill alarm wiring is not intrinsically safe. Repair prior to cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2021
Resolution: MI attended vessel. Confirmed repair of electrical installation and removed cargo restriciton from vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 August 2021Resolved
The piping systems installed on barges shall have the necessary flanges and fittings for safe and efficient operation of the vessel. Noted chaffed fuel supply hose to the #1 prime mover. Repair or replace w/in 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2021
Resolution: MI attended vessel. Witnessed satisfactory repair to fuel supply hose on STBD prime mover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 August 2021Resolved
Scantlings, material, and workmanship, shall be at least equivalent to the requirements of ABS or other recognized classification society. Noted 4 cracked/torn void hatch cover gaskets. Replace as noted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2021
Resolution: MI attended vessel. Confirmed repair of noted hatch gaskets.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 August 2021Resolved
A cargo tank connected to a VCS must be equipped with permanent or portable gauging that is a closed device. Noted gauging sight glass retaining rings were cracked. Replace or repair retaining rings for all 6 tanks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 August 2021
Resolution: Recieved photo documentation of replacement of sight glass gaskets, wipers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2021Resolved
All engine installations shall be of marine type engines suitable for the intended service. Unable to test port prime mover. Prove proper operation prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 August 2021
Resolution: MI attended vessel. Confirmed proper operation of PORT prime mover including emergency shutdown.
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 7 August 2020Resolved
Except as provided in paragraph (c) of this section, this subpart applies to each vessel that is constructed or adapted to carry, or that carries, oil in bulk as cargo or oil cargo residue, and the (1) Is a vessel of the United States; (2) Operates on the navigable waters of the United States; or (3) Transfers oil in port of place subject to the jurisdiction of the United States.
Vessel is currently authorized to carry oil products as per Cargo Authority Attachment Serial #: C1-1401284, dated 17-Apr-2014.
Vessel does not possess an approved Vessel Response Plan as required by 33 CFR 155.1015. Vessel is not authorized the carriage of any oil in bulk as cargo or oil cargo residue until an approved Vessel Response Plan is obtained.
33 CFR 155.1015
701 c
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2020
Resolved 19 August 2021
Resolution: Vessel does not carry oil VRP not required, IAW MSM Vol. II.
Construction/Loadline › Hull › Hull Plating
Issued 30 August 2016Resolved
Coast Guard Sector Houston personnel, while conducting a periodic inspection, noted an inset on the stern gunwale 2'x4" deep. Make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 2 September 2016
Resolution: Shipyard cropped and renewed a 3' X 6' plate on the stern gunwale. Witnessed sat air test of space.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 August 2016Resolved
Coast Guard Sector Houston personnel, while conducting a periodic inspection, were unable to internally inspect vapor control piping. Make vapor line available for internal inspection by a Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 2 September 2016
Resolution: Shipyard installed an inspection glass. All sat.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 30 August 2016Resolved
Coast Guard Sector Houston Galveston personnel, while conducting a periodic inspection, were unable to determine the last time the PV Valve was serviced or tested. Provide documentation to the satisfaction of the attending marine inspector on PV Valve servicing dates.
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 2 September 2016
Resolution: Barge sent PV Valve to Law Valve and had it serviced. All sat.