MAURY USCG vessel records
← All vessels

PISTI

PISTI is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in February 2025, along with 4 deficiencies and 5 operational controls.

Records from 2016 to 2025. Most recent: operational control imposed, 18 February 2025.

Built
2011
Last inspected
18 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 February 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9456367
1272496
Flag
LIBERIA
Maury page id
psix-1272496

Documentation record

Tonnage as PSIX records it32983 - Convention (Subpart B), Gross Ton
19191 - Convention (Subpart B), Net Ton
56897 - Dead Weight, Ton
67681 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

18 February 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8081026
17 February 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8080418
28 February 2024 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7871970
17 May 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7446211
14 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6414042
31 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115094
28 March 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112677
18 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6107186
4 August 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5958106
3 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5962041
31 July 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5958206
31 July 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5958652

Deficiency record · 4

Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 4 August 2016 Resolved
1410 - Propulsion main engine - Means shall be provided to control leaks of flammable liquids. PSCO observed multiple fuel leaks on the main engine, the number 1, 2, and 4 cylinder's high pressure fuel pumps, the number 4 cylinder's fuel injectors, and the number 6 cylinder's fuel injectors. 74 SOLAS (14) II-2/4.1.1 60ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 4 August 2016 Resolved
0750 - Fire Prevention - The fire resistance of doors shall be equivalent to that of the division in which they are fitted. PSCO observed that the A-60 door to the emergency fire pump room was not closing properly. 74 SOLAS (14) II-2/4.2.1 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: Crew fixed the door and it satisfactorily closed.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 August 2016 Resolved
0699 - Other (Life Saving Appliances) - Lifejackets shall be so placed as to be readly accessible and their positions shall be plainly indicated. While at another port the ship's crew moved the lifejackets and immersion suits from the bosun's store to the helicopter room, which was not in accordance with their lifesaving plan. 74 SOLAS (14) III/7.2.2.2 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 August 2016 Resolved
0715 - Detection - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The smoke detector in the engineer's work shop was covered with plastic. 74 SOLAS (14) II-2/14.2.1.2 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.