Records from 2016 to 2025. Most recent: inspection, 12 November 2025.
Inspection history · 18
12 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8254128
5 November 2025
Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8254121
5 May 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8121344
20 November 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8036540
1 December 2023
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7826572
16 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7836168
6 April 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7659265
7 March 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7407391
8 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7345924
4 March 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7149397
12 November 2019
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797465
3 December 2018
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570892
9 January 2018
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6331494
2 January 2018
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6335749
23 February 2017
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6093646
28 April 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5931324
18 February 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5815523
6 January 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5793196
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2025
Resolved
Observed single hose clamps on both priming bulbs. Vessel is required to have double hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: O/O added double hose clamps for each engine priming bulbs.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 November 2025
Resolved
Observed inadequate life line measured below the minimum required length of 60 feet. Vessel required to obtain proper length life line.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: O/O replaced with new throw line.
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 12 November 2025
Resolved
Observed the forward access gate handrail height measured below the required 39.5 inches. Vessel is to esnure it meets the 39.5" requirement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: O/O repaired front web netting, rail height is now 40".
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 November 2025
Resolved
Observed One portable fire extinguisher was found with a missing tamper seal and must be replaced with a new 10-B:C (or greater) rated unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: Fire extinguisher replaced in kind.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 November 2025
Resolved
Oil pollution placard was missing and must be installed in an accessible and visible location.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: O/O added oil pollution placard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 November 2025
Resolved
Stern navigation light was inoperative and requires repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 16 December 2025
Resolution: O/O replaced burnt out bulb.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025
Resolved
Remote fuel shut off stations must be marked. Fuel shut off valves not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: Marked fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025
Resolved
Shut off valves, installed so as to close against the fuel flow. Starboard side fuel shut off handle broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: replaced fuel shut off valve.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 May 2025
Resolved
Have mounted at the operating station, emergency instructions. Emergency instruction not present on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: Mounted emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2025
Resolved
Each child size life jacket must be separated from adult life jackets. Child life jackets stowed with adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: Child life jackets seperated in mesh bag.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2025
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Improper mounting of portable fire extinguisher. Provide approved fire extinguisher mounting bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: Properly mounted fire extinquisher.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 May 2025
Resolved
The flame screens must consist of a single screen of corrosion resistant wire of at lest 30x30 mesh. Replace with proper screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 19 May 2025
Resolution: Installed flame screen.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 December 2023
Resolved
Port navigation light is inoperable.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2023
Resolved
Mark fuel shutoff valves in clearly legible letters at least 1" high.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2023
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 December 2019
Resolved
Provide current FCC Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 December 2019
Resolved
Update emergency instruction list to include abandon ship.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: updated the emergency instruction list
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 December 2019
Resolved
Mark the location of child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 February 2020
Resolution: marked the location of the child life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2019
Resolved
Repair/replace life floats to be in compliance with original design. Vessel limited to 3 mile route.
Action required: 705 - Other - as specified
Resolved 23 January 2020
Resolution: vessel requested to be on a 3 mile route and remove life floats
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 November 2019
Resolved
Tabbing on frames coming off, to include the aft 11 frames on the centerline and the outboard sides of the aft 4 frames. Grind down/remove deteriorated tabbing and replace. submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 3 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 November 2019
Resolved
Blisters found and identified on hull, grind down to good glass and repair in accordance with current layup schedule. submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 11 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 November 2019
Resolved
3 of the 4 Hydraulic hoses and fittings are deteriorated. Replace hydraulic hoses and fittings.
Action required: 705 - Other - as specified
Resolved 11 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2018
Resolved
Ground Port and STBD fuel tanks to a common ground. Grounding wires were missing or detached from tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2018
Resolution: Grounding wires installed don fuel tanks.
Construction/Loadline › Hull › Bottom Plating
Issued 9 January 2018
Resolved
Make repairs to identified areas on hull.
Action required: 705 - Other - as specified
Resolved 19 January 2018
Resolution: Repaired all identified areas.
Communications › Radio Communications › EPIRB
Issued 2 January 2018
Resolved
Provide valid NOAA registration for EPIRB
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 22 January 2018
Resolution: New registration provided.
Communications › Radio Communications › EPIRB
Issued 2 January 2018
Resolved
Replace hydrostatic release for EPIRB. Reduced to 3nm from land.
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 2 January 2018
Resolution: New hydrostatic release provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 January 2018
Resolved
Replace battery for floating waterlight for ring buoy. Restricted to daylight operations.
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 4 January 2018
Resolution: Battery replaced.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 January 2018
Resolved
Provide 2 working portable lights.
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 2 January 2018
Resolution: New batteries installed.
Lifesaving › Lifefloat › Markings
Issued 2 January 2018
Resolved
relabel vessel name and capacity for both lifefloats. Replace SOLAS tape on port L/F
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 14 June 2018
Resolution: Vessel name and capacity labeled.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 January 2018
Resolved
Relabel remote fuel shutoff valves.
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 14 June 2018
Resolution: Fuel shut-offs labeled.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 January 2018
Resolved
Provide proof of enrolment into Drug and Alcohol program. Captain
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 4 January 2018
Resolution: Proof provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 January 2018
Resolved
Provide FCC operator permit.
Due 9 January 2018
Resolved 4 January 2018
Resolution: FCC operator permit provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017
Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 11 April 2017
Resolution: GPS input provided to VHF radio.
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 February 2017
Resolved
Provide life jacket donning placard for PFD's onboard.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 31 March 2017
Resolution: Placard posted.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 February 2017
Resolved
Label fuel shut off station for STBD side tank.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 31 March 2017
Resolution: Fuel shut off labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 February 2016
Resolved
Vessel did not have full first aid kit as required by 46 CFR 184.710
Due 18 March 2016
Resolved 18 February 2016
Resolution: First aid kit replaced during inspection.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 February 2016
Resolved
Emergency instructions on board did not reflect actual procedures/equipment on board. Required vessel to update procedures to reflect actual practices.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 11 March 2016
Documentation › Markings/Placards › Warning Signs
Issued 18 February 2016
Resolved
Vessel did not have emergency broadcast placard as required.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 February 2016
Resolution: Placard posted.