Records from 2016 to 2026. Most recent: inspection, 20 January 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portKAILUA KONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
20 January 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8298853
8 April 2025
Damage Survey · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8109203
19 September 2024
Deficiency Check · Examination of Repairs · COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8008196
17 January 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7622878
13 May 2021
In-Service Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7242032
15 May 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7242018
9 April 2020
Administrative Inspection · Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6952154
14 February 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6619974
2 May 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6405328
11 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6391319
28 March 2017
Administrative Inspection · Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6112406
8 April 2016
Administrative Inspection · Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5914361
Documentation › Logs/Records › Drug Test Records
Issued 11 April 2018
Resolved
Latest MIS report needs to be emailed for verification. Last MIS report was in 2016.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2018
Resolution: Operator emailed 2017 MIS Report.
Communications › Radio Communications › EPIRB
Issued 11 April 2018
Resolved
The EPIRB test shall be logged or documented. Vessel logged test, starting 11 APR.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2018
Lifesaving › Rocket Parachute Flares › General
Issued 28 March 2017
Resolved
Vessel needs to carry onboard the required amount of distress signals as required by the vessel’s route and service.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2017
Resolved 3 April 2017
Resolution: The vessel has been outfitted with the correct amount and type of distress signals.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2017
Resolved
Vessel needs to replace all expired medicines in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2017
Resolved 3 April 2017
Resolution: The vessel has removed all expired medication.
Communications › Radio Communications › EPIRB
Issued 28 March 2017
Resolved
Vessel needs to replace EPIRB hydrostatic release unit with a valid one.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 3 April 2017
Resolution: The vessel replaced the EPIRB hydrostatic release.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 March 2017
Resolved
Vessel needs to provide proof of a valid Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 3 April 2017
Resolution: The operator of the vessel provided a valid Certificate of Documentation.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 28 March 2017
Resolved
Vessel needs to establish a waste management plan.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 3 April 2017
Resolution: The vessel posted a waste management plan onboard.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 March 2017
Resolved
Vessel needs in-water emergency procedures.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 3 April 2017
Resolution: The vessel has posted emergency in-water procedures.