MAURY USCG vessel records
← All vessels

G. ARETE

G. ARETE is a 2013 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in May 2026, along with 7 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
2013
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9621584
1272990
Flag
PANAMA
Maury page id
psix-1272990

Documentation record

Tonnage as PSIX records it47459 - Convention (Subpart B), Gross Ton
54597 - Dead Weight, Metric Ton
73583 - Displacement, Metric Ton
15984 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

26 May 2026 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8380581
7 March 2026 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8321307
2 January 2025 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8054314
2 February 2024 COC-GAS Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7857934
27 December 2022 COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7613460
15 February 2022 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7394235
30 December 2020 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7116693
13 October 2020 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7076748
22 January 2020 PSC B · COC-GAS Annual · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6884649
27 November 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6578924
5 April 2017 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6113925
14 March 2016 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5829301

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 March 2026 Resolved
ELECTRICAL INSTALLATIONS SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS. PSCO OBSERVED APPROXIMATELY TWELVE BROKEN OR MISSING GROUNDING STRAPS ON DECK. ADDITIONALLY, PSCO OBSERVED 02 EXPOSED ELECTRICAL INSTALLATIONS IN THE CARGO COMPRESSOR ROOM AND 02 OUT ON DECK. 74 SOLAS (24) VII/13.1 IGC 93 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2026
Resolution: Received photos and class report attesting to repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 March 2026 Resolved
A GAS CARRIER SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL GAS CARRIER CODE. GAS DETECTION EQUIPMENT SHOULD BE SO DESIGNED THAT IT MAY BE READILY TESTED. PSCO OBSERVED A LEAK IN THE FIXED GAS CABINET FROM ONE OF THE CARGO HOLD SPACES. 74 SOLAS (24) VII/13.1 IGC 93 13.6.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2026
Resolution: PSCO OBSERVED CREW REPAIR LEAK IN THE FIXED GAS CABINET.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 March 2026 Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. PSCO OBSERVED THAT THE LOAD LINE MARK WAS NOT OF WHITE OR YELLOW ON A DARK BACKGROUND. ICLL (88) REG. 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2026
Resolution: Class report submitted. See attachments
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 January 2020 Resolved
(f) Each flammable gas detection system must have an audible and visual alarm for power failure and loss of gas sampling flow; and (s) Each flammable gas detection system must have at least one flow meter capable of measuring the flow to the gas analyzer, and must provide a means for ensuring that there is a positive flow in the right direction in each sampling line at all times. During a test of the fixed gas system, it was found that the low flow alarm was not being activated and the flow meter was not responding to flow changes. The flow was tested from the number 4 tank holdspace aft and locally in the cabinet. The crew disassembled and repaired the flow meter. After further troubleshooting, the crew could not get the low flow alarm to work properly or in accordance to design. 46 CFR 154.1350(f) & (s) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2020
Resolved 23 January 2020
Resolution: Received Class Survey Report attesting that flow sensor was installed in reverse. Crew overhauled flow sensor, re-installed properly and alarm faculty was verified by surveyor. See attached report in Documents.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 5 April 2017 Resolved
0735 - All of the 06 required fire fighter’s outfits onboard were in significant degraded condition as evident by excessive amounts of torn and missing fire protective shielding; additionally, 01 self contained breathing apparatus regulating valve was stuck in the open position and is in an inoperable condition rendering vessel unfit for fire fighting readiness. 74 SOLAS (14) II-2/14.2.1.2 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 6 April 2017
Resolution: Received class report attesting to the purchase and receipt of 05 new firemans outfits.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 April 2017 Resolved
1199 -The port side middle enclosed light in way of the port bulkhead is cracked in the casing caused by weathering from the ventilation casing, compromising the integrity of the light and posing an electrical fire hazard in the cargo compressor room. 74 SOLAS (14) VII/13.1 IGC Code 10.2.4 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 April 2017
Resolution: Received class report attesting to the replacement of the light, and a plan for permanently moving the light at next drydock.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 5 April 2017 Resolved
2550 - Objective evidence shown that during maintenance, non conformities pertaining to fire fighting equipment were not reported, corrective actions were not taken, and maintenance logs did not accurately reflect fire fighting equipment in their respective substandard condition. 74 SOLAS (14) IX/3.1 ISM Code A 10 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 April 2017
Resolution: Received class report attesting to proper training to the crew in SMS procedures for preventative maintenence.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.