MAURY USCG vessel records
← All vessels

G. PARAGON

G. PARAGON is a 2013 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in October 2025, along with 3 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 21 October 2025.

Built
2013
Last inspected
21 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 October 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9656888
1273126
Flag
PANAMA
Maury page id
psix-1273126

Documentation record

Tonnage as PSIX records it54776 - Dead Weight, Metric Ton
73790 - Displacement, Metric Ton
46786 - Convention (Subpart B), Gross Ton
18589 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

21 October 2025 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8255454
16 September 2024 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8002771
13 October 2023 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7806920
8 August 2022 PSC B · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7527956
24 September 2021 Ballast Water Examination · ISPS Exam · COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7318403
30 July 2020 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7013318
31 January 2019 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6611913
24 January 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6614764
19 April 2018 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6391893
20 January 2017 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6072084
10 February 2016 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 5925676
11 January 2016 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5792504

Deficiency record · 3

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 19 April 2018 Resolved
01 1138 - Gas Carriers - Gas detection equipment should be so designed that it may readily be tested. Suitable equipment and span gas for this purpose should be carried onboard. The vessel did not have the appropriate equipment onboard to test the fixed gas detection in the motor room. The crew was using a plastic grocery sack instead of the proper cap which connects to the span gas bottle. 74SOLAS (14CONS) VII/13.1 IAW Ref: IGC 93/13.6.6
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 January 2019
Resolution: Deficiency rectified through submission of sufficient documentation attesting to receipt and use of proper testing equipment for gas detection system.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 19 April 2018 Resolved
02 1138 Gas Carriers - Pressure relief valves should be set and sealed by a competent authority acceptable to the administration. While conducting tank top examinations. PSCOs found pilot and auxiliary relief valves missing set seals on each tank top. 74SOLASVII/13.1 IAW REF: IGC 93/8.2.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 January 2019
Resolution: Deficiency rectified due to submission of sufficient documentation attesting to replacement of missing set seals. Company issued fleet notification to carry out close checks of seals in the future.
Documentation › Logs/Records › Logbook (official)
Issued 19 April 2018 Resolved
03 1138 Gas Carriers - The changing of set pressures should be recorded in the ship's log stating the set pressure. The crew did not document the change to "harbor" setting on 04MAR18. 74SOLASVII/13.1 IAW Ref: IGC 93/8.2.7
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 January 2019
Resolution: Deficiency rectified due to submission of sufficient documentation attesting to addition of missing logbook entry. Company also issued fleet wide notification to ensure changes to cargo tank safety relief valve pressure settings are recorded in ship log.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.