← All vessels
JAVA
Freight Ship · Bulk Carrier class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named JAVA
JAVA is a 2014 freight ship. The Coast Guard has recorded 15 inspections since 2015, most recently in February 2026, along with 20 deficiencies and 1 casualty investigation in 2015.
Records from 2015 to 2026. Most recent: inspection, 23 February 2026.
- Built
- 2014
- Last inspected
- 23 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
1256411
9724245 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP9474
1273132
Flag
UNITED STATES
367643990
Maury page id
psix-1273132
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)178.0 ft × 39.8 ft × 14.0 ft
Registered tonnagegross 89 / net 60
ITC dimensions (L × B × D)178.0 ft × 39.8 ft × 14.0 ft
ITC tonnagegross 877 / net 263
BuilderC&C MARINE AND REPAIR LLC · BELLE CHASSE, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 August 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
877 - Convention (Subpart B), Gross Ton
1300 - Dead Weight, Gross Ton
680 - Displacement, Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
263 - Convention (Subpart B), Net Ton
877 - Convention (Subpart B), Gross Ton
1300 - Dead Weight, Gross Ton
680 - Displacement, Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
263 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP9474MMSI 367643990 · active · compulsorily equipped · granted 4 January 2025, expires 4 January 2035
WDH7025MMSI 367643990 · expired · compulsorily equipped · granted 16 October 2014, cancelled 21 December 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 15
23 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8305686
2 December 2024
Cargo Tank Internal · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8041874
1 March 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7872971
27 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7871279
8 December 2022
Periodic Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7606066
23 February 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7400223
9 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7092071
25 November 2019
Administrative Inspection · Internal Structural Exam · COI Inspection · Cargo Tank Internal · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6865714
17 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6814347
7 December 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6595563
6 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6319171
27 November 2017
Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6313077
9 December 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6055429
28 January 2016
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5836171
30 September 2015
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5735696
Deficiency record · 20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 February 2026
Resolved
Main propulsion machinery must be shut down in case of failure that could lead to damage, breakdown, or explosion. STBD Main engine was unable to be treated for overspeed function due to updates required on engine software.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2025
Resolved
Machinery driving forced-draft and induced draft fans, fuel-oil transfer pumps, fuel-oil unit and service pumps and similiar fuel-oil pumps must be fitted with remote controls from a readily accessible poistion outside the space concerned so that the fans or pumps may be stopped in case of fire. All of vessels remote valves are bound and need assistance closing. Ensure remote valves operate without assistance to the satisfaction of attending MI.
46 CFR 58.01-25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2025
Resolved
A nonmetallic expansion joint must be replaced 10 years after it has been placed into service if it is located in a system which penetrates the side of the vessel and both the penetration and the nonmetallic expansion joint are located below the deepest load waterline. Expansion joints beyond 10 years and need to be changed. Install new expansion joints to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024
Resolved
No OSV may be operated without a valid Certificate of Inspection. Vessel's COI became invalid due to failure of vessel not undergoing an annual inspection within 3 months of the anniversary date (21NOV2024). 705 - Vessel may not operate commercially.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 8 December 2022
Resolved
Inspections of lifesaving equipment are carried out at each inspection to show proper condition.
Wire rope for rescue boat davit has broken strands and is deteriorated.
Replace wire rope and conduct weight test
46 CFR 133.45(b)
46 CFR 131.550(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 February 2022
Resolved
Each watertight door must be watertight (withstand a head of water from door sill to bulkhead deck). Emergency escape door in engien room has a one inch gap in gasket at the bottom. 46 CFR 176.210
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 February 2022
Resolved
Each entrance to a space storing CO2 cylingers must be marked. CO2 storage space is not properly marked. 46 CFR 131.817(a)
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 February 2022
Resolved
Rescue boat must be marked on each side of the bow with name, hailing port, length and beam of boat, and number of persons it will hold. Rescue boat is not properly marked. 46 CFR 131.855
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 February 2022
Resolved
Switchboards accessible from the rear must have nonconductive mats on the deck. No mat present behind switchboard. 46 CFR 129.330(g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2022
Resolved
No vessel's hull may carry current as a conductor. A ground (3 AMPS) is showing on stbd/port back up panel. 46 CFR 129.375
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 February 2022
Resolved
Vessel has fire detection system installed. detection panel on bridge shows fault. 46 CFR 132.340
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 November 2020
Resolved
Twenty five cartridges of the caliber and loading specified in the in structions furnished by the manufacturer of the gun must be provided.
Vsl had 20 cartridges.
Ensure VSL has 25 Cartridges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 December 2019
Resolved
Each watertight door must be watertight. Three watertight doors and one emergency escape hatch gaskets in the engine room were not watertight. Replace the gaskets and make adjustments to the following doors/hatches: (1) Engine room forward watertight door. (2) Steering room watertight door. (3) Engine room emergency escape watertight door and hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2019
Resolved
Identify and clear 2.5 amp ground detected on the starboard back up panel in the engine room. Conduct test of the port backup panel to ensure proper operation of ground detector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 December 2019
Resolved
Vent outlets from all tanks which may emit flammable vapor must be fitted with a flame screen. Replace damaged flame screen on the number 4 starboard fuel oil vent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 December 2019
Resolved
Each lighting fixture must have a guard if it could be subject to damage. Replace missing guard for the fluorescent light above the main switchboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2019
Resolved
Emergency lighting must automatically actuate upon loss of normal power. Prove proper operation of two emergency lights in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 December 2019
Resolved
Demonstrate proper condition and operation of the rescue boat launching applicance at loads ranging from light load to full load and conduct annual servicing of launching appliance.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 December 2018
Resolved
Vessel's rescue boat davit was installed four years ago and davit cable was not end for ended at 30 month period. Rescue boat davit cable must be replaced in accordance with CFR cite.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 December 2018
Resolved
Rescue boat davit is releasing hydraulic fluid from accumulator when slewing davit in and out. Repair davit to original condition.
Casualty record · 1
29 April 2015Routine · role: Involved in a Marine Casualty · activity 5117963
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.