MAURY USCG vessel records
← All vessels

THREE WOLVES

THREE WOLVES is a 2014 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in April 2026, along with 59 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 19 April 2026.

Built
2014
Last inspected
19 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5597
1273367
Flag
UNITED STATES
Maury page id
psix-1273367

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 4.1 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH RIVER BOATS · ROSEBURG, OR, UNITED STATES · built 2014
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portHOONAH, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 13 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 24

19 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8352264
18 April 2026 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8351854
16 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8328896
1 October 2025 Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8245051
23 April 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101419
21 March 2024 Annual Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874691
19 April 2023 Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7668401
9 May 2022 Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7445023
28 March 2022 Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7429133
20 July 2021 Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7258554
10 March 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7162773
8 October 2020 Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7077123
7 July 2020 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7003027
3 March 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6923486
27 January 2020 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6934656
20 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6720168
6 May 2019 Internal Structural Exam · Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6674619
12 March 2019 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6641433
11 May 2018 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6412190
30 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6409510
5 April 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6389707
5 May 2017 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6137572
8 September 2016 Administrative Inspection · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5988789
9 May 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5873796

Deficiency record · 59

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 April 2026 Resolved
(d) A flammable vapor detection system must provide a visual and audible alarm at the operating station. Mid vapor detector is not working.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 April 2026 Resolved
(b) Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Middle outboard is not registering RPM. 46 CFR 182.410(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 April 2026 Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. Vessel's radio is not working. 47CFR 80.901
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2026 Resolved
The official number of the vessel, preceded by the abbreviation "NO" must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. If the official number is on a separate plate, the plate must be fastened in such a manner that its removal would normally cause some scarring of or damage to the surrounding hull area. Vessels official number plate loose in bilge. Permanently affix official number plate as required. 46 CFR 67.121
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2025 Resolved
Prevent electrical ignition of flammable vapors. Junction box in aft space (gasoline tank void) is missing front cover. 46CFR182.200(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
Resolution: Junction box cover re-installed and verified; all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 April 2025 Resolved
A cable may be spliced in a location, other than a hazardous location. Port sdie navigation light is not properly spliced. Wiring can be pulled out easily and splice connection is loose. 46CFR183.340(m)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
Resolution: Wiring secured and spliced properly; all sat
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 April 2025 Resolved
Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA set up was installed upside down. Corrected on the spot. 46CFR180.130(a)(2)
Action required: 10 - Deficiency Rectified
Due 23 April 2025
Resolved 23 April 2025
Resolution: Corrected on the spot and verified; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 April 2025 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. On board horn is non operational.33CFR83.33
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
Resolution: Horn repaired and tested; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI discovered two 2 gallon fire buckets on vessel. Ensure all fire buckets are 2.5 gallons, and a total of three 2.5 gallon fire buckets are onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 2 May 2024
Resolution: Fire buckets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2024 Resolved
(1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113 (incorporated by reference; see 46 CFR 175.600). Bilge pumps do not meet UL rating requirement. Install bilge pumps meeting UL 1113 rating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 2 May 2024
Resolution: Installed UL approved bilge pumps
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 April 2024 Resolved
(l) Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation ducts for vessel bilge are unable to secure properly due to bungee straps being stretched out. Replace bungee straps in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 23 April 2025
Resolution: Verfied, straps were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 April 2024 Resolved
(2) A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter Ring life buoy on vessel was found to be deteriorated. Replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 23 April 2025
Resolution: Life buoy was replaced; all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 April 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic release for EPIRB labeled with incorrect expiration date. Date of expiration is two years from the date of install on the vessel. Correct date or replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 23 April 2025
Resolution: New hydrostatic unit was installed; all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 April 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels VHF antenna was broken and temporarily repaired with sticks and tape. Replace broken VHF radio antenna.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Owner replaced the broken antenna with a new one tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2023 Resolved
A vessel must be provided with bilge pumps in accordance with On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. (b) Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. (c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The aft bilge high water alarm was not working. Repair the aft high bilge alarm maintain a watch of the space until the alarm is repaired. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Operator replaced faulty float switch and tested - all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. The aft breaker panel is missing a circuit breaker (open slot). Blank off or reinstall breaker into panel to eliminate open slot. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Operator replaced missing circuit breaker that was inside of the panel and tested - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Owner replaced the old nav charts with 2023 nav charts - all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2022 Resolved
Fixed pre-engineered fire systems must have an audible and visual alarm at the operating station alerting the operator the system has been discharged. The fire boys audible alarm is not working. Repair or replace the audible alarm. 46 CFR 181.420
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2022
Resolved 9 May 2022
Resolution: Owner replaced the audible alarm with a new one tested - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2022 Resolved
Vessel is required to have one CG Approved Type I PFD for each person onboard. Vessel is missing two adult PFDs. Vessel is reduced to 26 total persons allowed onboard. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 9 May 2022
Resolution: Owner provided two new CG Approved Type I PFDs, stenciled with the vessels name - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2021 Resolved
Vessel is required to have one Type I PFD for total persons allowed onboard. Vessel is missing two adult CG Approved, Type I PFD.46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: The owner provided two additional CG approved type I PFDs stenciled with the vessels name - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 July 2021 Resolved
Vessel is required by D17 policy to have 100% IBA for vessels routes. Vessels IBA was not onboard at the time of the inspection, still at servicing station.46 CFR 176.110
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: IBA was serviced and properly installed onboard the vessel with a new hydraulic release - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2021 Resolved
Vessels life ring buoy shall have the vessels name, stenciled onto it. Life ring buoy is missing the vessels name.46 CFR 185.604(b).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Operator re-stenciled the vessels name onto the life ring buoy - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 July 2021 Resolved
Vessel is required to display the appropriate navigation light iaw international navigation rule. Vessel starboard side navigation and aft navigation lights are not working, starboard side light is blue should be green.46 CFR 183.420
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner replaced the navigation light fixture. - all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2021 Resolved
Vessel is required to have x3 Three, 2.5 gallon fire buckets onboard with line attached, stenciled "FIRE BUCKET". Two of the vessel's fire buckets are missing dip line. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Operator provided x3 2.5 gal fire buckets stenciled FIRE BUCKET with lanyards attached - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 July 2021 Resolved
Vessels charts shall be maintained up to date. Vessels navigation charts were out of date, not maintained.46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner provided updated charts onboard the vessel - all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 20 July 2021 Resolved
Vessel owner is required to provide and maintain a first aid kit onboard the vessel. Items (aspirin) in the first aid kit are expired.46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner updated first aid kit - all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2021 Resolved
Vessel shall be outfitted with two portable flashlights. One of the two flashlights was not working.46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner replaced the two flashlights with brand new ones - all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 July 2021 Resolved
Vessel is required to maintain FCC Safety Certificate. Vessel's FCC safety certificate is expired.46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner had the FCC Safety Certificate renewed - all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2021 Resolved
Vessels fuel tank void is required to have a CG approved fixed fire system installed. Vessels pre-engineered fire boy system was condemned by the fire servicing company. Have system restored to original / replace in kind and have remote pull, ventilation shut down, and alarms tested by an approved fire service company. Provide report to the Marine Inspector for review/approval.46 CFR 181.400
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner had fire servicing company replace the pre-engineered system with a new exact replacement - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 July 2021 Resolved
Vessel is required to have onboard international navigation rules, and up to date tide and current information. Vessel's tide and current books are out of date. International navigation rules copy not onboard the vessel.46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2021
Resolved 9 May 2022
Resolution: Owner provided all required and up to date navigation publications onboard the vessel - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 6 May 2019 Resolved
Install permanent draft/load marks on vessel by April 1, 2020 as per Vessel’s stability letter dated May 23 2013 and install temporary mark before passengers
Action required: 705 - Other - as specified
Resolved 9 May 2022
Resolution: Owner had permanent draft marks installed onto the hull of the vessel - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2019 Resolved
Replace Life ring buoy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2019
Resolution: Vessel has rpelaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2019 Resolved
Replaced expired battery in life ring buoy light prior to operating at night low visibility
Action required: 705 - Other - as specified
Resolved 20 June 2019
Resolution: Vessel has RCVD and installed new battery in life ring bouy light,
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 May 2019 Resolved
Provide up to date tide book and light list
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2019
Resolution: Vessel has updated Tide book and Light list onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2019 Resolved
Provide a first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2019
Resolution: Vessel provide new first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 May 2019 Resolved
Prove company is enrolled in a Marine Consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2019
Resolution: Company has provided current Marine Consortium paperwork with vessels crew listed.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 30 April 2018 Resolved
Conduct annual servicing of IBA
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Vessel has had the IBA serviced
Communications › Radio Communications › EPIRB
Issued 30 April 2018 Resolved
Replace expired hydrostatic release on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Vessel has replaced the Hydrostatic release
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 30 April 2018 Resolved
Replace recalled 10-bc fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: vessel has replaced the 10-bc
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 April 2018 Resolved
Replace all expired contents of the first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: vessel has replaced expried contents
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 April 2018 Resolved
Provide updated U.S. Coast pilot and Coast guard light list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: vessel rcvd new coast pilot and light list.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 April 2018 Resolved
Prove current enrollment in a USCG Consortium
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: vessel has provide enrollment cert.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 April 2018 Resolved
Provide and display/make available on-board EAP program element
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: vessel has meet the EAP program elementd
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 April 2018 Resolved
Prove EAP training program is in place and training is being conducted and documented
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Vessel has meet the EAP training requriments
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 April 2018 Resolved
Replace expired Alcohol testing strips
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2018
Resolution: vessel has replaced alcohol testing strips
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 5 May 2017 Resolved
Master is required to maintain an FCC Radio Operator Permit, but did not have the permit onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 23 May 2017
Resolution: Master provided permit from FCC issued in 2014.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 5 May 2017 Resolved
Vessel is required to maintain alcohol testing equipment onboard, no equipment was onboard during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Master provided proof of valid alcohol test strips onboard.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 5 May 2017 Resolved
Fire extinguisher's exceeded their service date. Master required to have Extinguishers serviced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Master provided proof of fire extinguisher servicing by SE Extinguishers.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 May 2017 Resolved
Vessel Master did not have proof of enrollment for company personnel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Master provided proof of enrollment with TSS.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 8 September 2016 Resolved
Renew expired hydrostatic release for vsl's IBA. Vessel restricted to no more than six passengers until resolved.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 12 September 2016
Resolution: Vsl's Master replaced the expired with a new Hydrostatic Release unit.
Operations/Management › Pollution › Control of Garbage
Issued 8 September 2016 Resolved
Properly post (waste) garbage management placard visible to passengers and crew.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 14 October 2016
Resolution: Owner purchased and posted a garbage management placard visible to passengers and crew.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2016 Resolved
Properly repair vsl's anchor light.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 23 September 2016
Resolution: Owners mechanics repaired faulty connection on anchor light. Light is working properly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 September 2016 Resolved
Re-stencil vsl's name onto life ring buoy.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 23 September 2016
Resolution: Crew re stenciled vsl's name onto life ring buoy.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 8 September 2016 Resolved
Rig anchor ready for immediate use.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 13 September 2016
Resolution: Owner removed anchor line from plastic wrapped spool and rigged ready for immediate use.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2016 Resolved
Renew expired items in vsl's first aid kit.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 14 October 2016
Resolution: Owner purchased a new first aid kit with all of the required items and placed it onboard the vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 September 2016 Resolved
Renew expired alcohol test strips.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 12 September 2016
Resolution: Vsl's Master replaced the two expired Alcohol Test Strips with new unexpired test strips.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 September 2016 Resolved
Have onboard original non expired COD.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 12 September 2016
Resolution: Owner located and placed the original COD onboard the vessel.
Communications › Alarms/Indicators › Fire Alarm
Issued 8 September 2016 Resolved
Properly repair the fwd vapor detection system.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 14 October 2016
Resolution: Owner replaced a faulty alarm unit at the operating station and system is now fully operational.
Communications › Radio Communications › EPIRB
Issued 8 September 2016 Resolved
Renew expired NOAA registration for vsl's EPIRB.
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 13 September 2016
Resolution: Owner renewed NOAA EPIRB registration and placed copy onboard the vessel.

Ownership record