MAURY USCG vessel records Sign in
← All vessels

RIVERSONG

RIVERSONG is a passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2014, most recently in June 2020, along with 6 deficiencies — 2 with no resolution recorded —.

Records from 2014 to 2020. Most recent: inspection, 19 June 2020.

Built
Not recorded
Last inspected
19 June 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1273627
Flag
UNITED STATES
—
Maury page id
psix-1273627

Inspections, by type

…past their stated due date2
Years with a record 5 calendar years (2014–2020)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

19 June 2020 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6980846
26 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6931934
19 June 2019 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6718010
21 May 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6420294
9 May 2018 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6410349
24 April 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6398598
17 September 2015 Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5724814
15 August 2014 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4955412
15 August 2014 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4966665

Deficiency record · 6

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 September 2015 No resolution recorded
Provide annual servicing report for installed Fireboy engine room extinguishing system and portable extinguisher.
Action required: 705 - Other - as specified
Due 30 October 2015 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 September 2015 Resolved
Repair or replace bow combination navigation light.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Documentation › Markings/Placards › Warning Signs
Issued 17 September 2015 Resolved
Label location of the emergency fuel shut off valve.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Engineering › Steering Gear System › Bracket/Clamp
Issued 17 September 2015 Resolved
Repair or replace fixed mounting point for the hydraulic ram.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 September 2015 Resolved
Provide a first aid kit approved under 46 CFR 160.041 or a kit with equivalent contents and instructions.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 13 October 2015
Construction/Loadline › Structures › Scuttle
Issued 17 September 2015 No resolution recorded
Repair the port forward bench seat in way of the access cover.
Action required: 705 - Other - as specified
Due 30 October 2015 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.