Records from 2016 to 2025. Most recent: inspection, 25 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)40.4 ft × 11.3 ft × 5.4 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSILVER SHIPS INC · THEODORE, AL, UNITED STATES · built 2014
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portEAST HARTFORD, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
13 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 13
25 August 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8201946
26 July 2024
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7956633
3 June 2024
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926307
25 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875974
18 October 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7810697
19 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7552352
28 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7311084
17 September 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7059308
24 July 2019
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6759612
11 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6660578
25 October 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6568669
13 October 2017
Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6287174
18 August 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5977021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 25 August 2025
Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Vapor detection for gasoline fuel system would not actuate. Prove proper operation of vapor detection system visual and audible alarm.
46 CFR 182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: installed and tested
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 August 2025
Resolved
Vessels COD expired 6/30/2025. Provide copy of valid COD or submission of COD prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
Resolution: renewed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 August 2025
Resolved
Vessels floating waterlight attached to the ring life buoy was inoperable. Operator replaced battery, but light would not illuminate. Provide working waterlight for ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2025
Resolved 10 September 2025
Resolution: completed, bought new light
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 August 2025
Resolved
Vessels on LBS routes required 6 flares (3 hand red, and 3 orange smoke OR 6 hand red). Flares on board were expired. Provide flares prior to operating on voyages beyond 30 min in duration.
Action required: 705 - Other - as specified
Resolved 5 September 2025
Resolution: 6 provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 September 2022
Resolved
Prove proper operation of gasoline vapor detection system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2022
Resolution: New sensor and alarm installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2022
Resolved
Prove proper operation of stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2022
Resolution: New stern light installed,.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 September 2021
Resolved
Vessel had on board expired flares. Provide non-expired flares as appropriate: 3 red and 3 orange (or 6 red). Vesssel restricted to w/in 30min routes.
Action required: 10 - Deficiency Rectified
Resolved 28 September 2021
Resolution: provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 September 2021
Resolved
Vessel Owner/Operator required to have a Marine Employer Drug and Alcohol Program. Crew on board were in their own programs with no crew share agreement. Provide evidence of Marine Employer provided Drug and Alcohol Program, and list of covered employees (or crew share agreements).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 18 November 2021
Resolution: provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2018
Resolved
Flammable vapor detection systems must be installed in in a space containing a fuel tank. Vessel's vapor detection system is in operable. Prove proper operation of vapor detection system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2018
Resolved 24 July 2019
Resolution: Vapor detection system tested.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 August 2016
Resolved
Provide valid Certificate of Documentation.
Due 18 September 2016
Resolved 1 December 2016
Resolution: COD updated.