Records from 2013 to 2026. Most recent: inspection, 19 March 2026.
Inspection history · 15
19 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 8328862
21 February 2024
Cargo Tank Internal · Internal Structural Exam · MTSA Verification · Administrative Inspection · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7868233
20 April 2022
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7435996
10 July 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7000777
23 April 2019
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6671046
11 May 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6416199
2 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6404031
21 August 2017
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6248085
9 August 2017
Periodic Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6235177
19 August 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5974279
23 July 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5194395
15 July 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5183374
20 February 2015
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5070713
5 February 2015
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5064760
19 December 2013
Plan Review (Other than "T") · Administrative Inspection · Initial Construction-Excluding Oversight · Construction Oversight · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4771909
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 11 May 2018
Resolved
Gaskets on #1 stbd and port sight glasses were worn
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 16 May 2018
Resolution: Gaskets replaced
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 11 May 2018
Resolved
Valve stem indicator on the #1 stbd cargo tank not working properly
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2018
Resolved 16 May 2018
Resolution: Fixed valve indicator. Properly indicating valve position
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 May 2018
Resolved
Due to Owner/Operator and Vessel Name change, the VRP on board is not currently correct. Require updated VRP to be placed onboard vessel to the satisfaction of the attending CG Marine Inspector.
Vessel authorized continued full operations, route and service with current valid COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 7 June 2018
Resolution: VRP #20040 updated to add this barge. Copy of letter placed onboard barge.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 9 August 2017
Resolved
Cargo Tank of the Tank vessel connected to a vapor collection system must meet 46 CFR 151.15.10(c). Closed gauge system is leaking vapor, compromising cargo tank integrity.
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 9 August 2017
Resolution: Vessel rep tightened closed gauge housing and was able to restore vapor integrity meeting requirements prior to departure.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 9 August 2017
Resolved
Each cargo tank of a tank barge must have alarm that can be inspected at the tank for proper operation. Alarms were inoperable upon arrival.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2017
Resolved 21 August 2017
Resolution: Verified operation of alarms for overfill protection.