Records from 2016 to 2023. Most recent: inspection, 17 January 2023.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
9 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 9
17 January 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7622865
17 June 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6984827
12 February 2020
Deficiency Check · DAPI Audit · Administrative Inspection · In-Service Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6907948
2 May 2019
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6674725
26 February 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6632648
8 May 2018
Hull Examination · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6411417
3 May 2017
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6137709
14 February 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087876
3 February 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834858
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. STBD engine is not able to maintain speed under normal operating conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 27 February 2020
Resolution: The starboard engine had a bad coil on hte spark plug. It was replaced and the engine is operational.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 February 2020
Resolved
An exhaust blower motor may not be installed in a duct, and if mounted in any space required to be ventilated, must be located as high above the bilge as practicable. Blower blades must be non-sparking. Vessel owner must insall fixed ventilation in the enclosed space FWD of transom.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 27 February 2020
Resolution: The vessel installed ducts for natural ventilation and a fixed ventilation for proper air exchange where the gasoline fuel tank are located.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 February 2020
Resolved
Exhaust blower switches must be located outside of any space required to be ventilated and must be interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit of the engine ignition is energized. Exhaust blower switch must be interlocked with ignition switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 27 February 2020
Resolution: Exhaust blower switch at the helm is interlocked with the ignition switch. The blowers started before the engine starter motor circuit of the engine ignition was energized.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2020
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. Vessel owner was unable to conduct fire, abandon ship or man overboard drills due to STBD engine failure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 27 February 2020
Resolution: All required test and drills where performed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 February 2020
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment.The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of the T-Top alterations to the cognizant [name withheld] to the addition of the T-Top without approved place it should be removed or a new stability test must be conducted prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2020
Resolution: The removed the T-Top from the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2019
Resolved
Provide a satisfactory overpressure/baffle leak test for the inflatable tube collar that is installed onboard. The test needs to show adequate holding pressure of 1.5 times the manufactures recommended operating pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2019
Resolution: Vessel rep conducted a satisfactory overpressure and baffle leak test. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 February 2019
Resolved
Provide satisfacotry sea trials/drills in the prescence on an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2019
Resolution: Vessel rep completed satisfactory sea trials and drills in the presence of an attending marine inspector.