PIS PRECIOUS

PIS PRECIOUS is a 2013 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 20 March 2026.

Built
2013
Last inspected
20 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9689158
9V7493
1274593
Flag
SINGAPORE
Maury page id
psix-1274593

Documentation record

Tonnage as PSIX records it29700 - Convention (Subpart B), Gross Ton
13843 - Convention (Subpart B), Net Ton
60958 - Displacement, Ton
50258 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

11 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

20 March 2026 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8329339
9 March 2026 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8322998
6 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8031328
10 June 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7931555
10 June 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7931736
10 June 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932214
3 July 2021 VRP Review · COC-CHEM & TVE Renew · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7238926
14 September 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6540356
5 August 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6226362
20 October 2016 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6023263
4 August 2016 Administrative Inspection · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5962520

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 June 2024 Resolved
The purpose of this regulation is to limit the fire growth potential in every space... means of control for the air supply to the space shall be provided. PSCO observed the aft ventilation closure not fully securing the supply of air into the emergency generator space upon the closure being shut. 74SOLAS(20)II-2/5.1.1 16ac
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 12 June 2024
Resolution: Received and reviewed class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 June 2024 Resolved
The condition of the shp and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed improper tank level readings on CCR panel for tanks 5s and 2p. 74SOLAS(20)I/11(a) 16c - Cleared
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2024
Resolved 10 June 2024
Resolution: Cleared on the spot. Dirty cable was creating a sensor issue. Crew cleaned dirty cable and found to be in good working order after.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2024 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. PSCO observed grounding wires disconnected on 02 oil purifier pumps. 74SOLAS(20)II-1/45.1.1 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
Resolution: Cleared on the spot
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 September 2018 Resolved
The deck seal was holed due to corrosion and then repaired by crew's hand with epoxy. 74SOLAS(14)II-2/5.5.1.1, FSS Code 5.2.2.1.1 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2018
Resolution: Class recommended that the permanent repair be completed by October 31, 2018. Class tested IG seal alarms, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2018 Resolved
The cargo sensor cables are exposed to the hazardous atmosphere in the vicinity of P&S cargo manifolds. 74SOLAS(14)II-1/45.11 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2018
Resolution: It was confirmed that these cables are used for the intrinsically safe type electrical equipment (Pressure sensors for cargo line). It doesn't affect to the hazardous atmosphere. Class has no objection to the current condition.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2018 Resolved
Personal equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The outer surface shall be water-resistant. Three (03) firefighting suits were found with tearing of protective coating. 74SOLAS(14)II-2/10.1.1, FSS Code 3.2.1.1.1. 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2018
Resolution: t was confirmed that three sets of teared firefighting suites were replaced with new ones at this time. All sets of firefigl1ting suites installed in ship are now in good condition