Records from 2015 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 23
15 June 2026
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8405652
3 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8390387
16 September 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050468
3 June 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050463
14 November 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8035088
6 June 2024
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855591
20 September 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640447
7 June 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640442
14 June 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7478784
15 September 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7312497
27 July 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7269876
16 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7225595
15 July 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7006657
18 September 2019
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6814464
10 June 2019
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702865
22 September 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6547819
17 July 2018
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6481870
22 January 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6341857
27 September 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6274692
19 June 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6178043
4 June 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6192005
8 April 2016
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5852129
25 February 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5822345
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed head of screw sheer off and cause off of propulsion in port engine during MOB drill. Replace external snap ring to satisfaction of attending MI.
46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2026
Resolution: Received video of port engine operating properly with replacement part; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2026
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. MI found vessel to have no PMP or third party surveyor report. Create PMP in accordance with NVIC 02-16 to satisfaction of attending MI.
46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 26 June 2026
Resolution: Received 3rd party survey report, uploaded to activity.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2026
Resolved
On a vessel of not more than 19.8 (65 feet) in length carrying more than 49 passengers…each hose must conform to UL 19, be 50 feet in length and 1.5 inches in diameter, and have fittings of brass or other suitable corrosion-resistant material. MI observed fire house on board rupture. Vessel passenger count reduced to 49 until replacement of hose is completed to satisfaction of attending MI.
46 CFR 182.200(a)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 15 June 2026
Resolution: Corrected, received a video showing good flow.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 June 2025
Resolved
The lifeline and pendants must be furnished by the manufacturer with the approved life or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Each buoyant apparatus must have a life line securely attached around the outside, festooned in bights no longer than 1m (3ft), with a seine float in each bight, unless the line is of an inherently buoyant material and absorbs little to no water. The lifeline must be at least 10mm (3/8 inch) diameter and have a breaking strength of a least 5400 N (1215 lb). Vessel's lower buoyant apparatus lifelines were deteriorating. Replace lifeline to the satisfaction of the Marine Inspector.
46 CFR 180.175 (f)(1)
46 CFR 160.010-4 (f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 4 June 2025
Resolution: Cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instruction. Vessel did not have 48 analgesic medications (aspirin). Provide 48 aspirins for first aid kit to the satisfaction of the attending Marine Inspector.
46 CF 184.710
Action required: 10 - Deficiency Rectified
Resolved 3 June 2025
Resolution: Vessel provided evidence that at least 48 Aspirin was inserted into first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 June 2024
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018. All 88 adult life jackets were not marked with appropriate retro-reflective material. Provide appropriate markings to the satisfaction of the attending marine inspector prior to taking on passengers.
46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2024
Resolution: New retro-reflective tape was installed on all 88 life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Each small battery installation must be protected from falling objects. Both the ungrounded and grounded conductors for the small battery installation in the starboard engine room were unprotected from falling objects. Provide protection for the battery.
46 CFR 183.354(b)
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: A cover for the battery was provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 June 2021
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Vessel missing flame screens on port and stbd fuel tank vents. Install flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 19 June 2021
Resolution: Vessel installed flame screens on vents.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 June 2021
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of all overboard discharge and intake valves and watertight bulkhead pipe penetrations. Vessel's aft stbd bilge overboard discharge valve handle was broken. Replace valve handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 18 June 2021
Resolution: Vessel replaced broken bilge ovbd valve and handle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 June 2021
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: on each life float and buoyant apparatus. Vessel's name is peeling off the life float. Paint or mark clearly legible letters to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 18 June 2021
Resolution: Vessel permanently marked name on lifefloat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 July 2020
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The fire pump inlet hose is leaking from both the top and bottom of the hose connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2020
Resolution: Fire pump inlet hose was replaced in-kind. Successful operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2020
Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for lifefloats and buoyant apparatus must meet the following specifications: the light must be a a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. 1 of the 2 lifeloats does not have it's own floating waterlight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 31 July 2020
Resolution: New floating waterlight has been mounted and attached to the second lifefloat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. The port generator fuel line was chafted and worn through the outer protective layer and down to the metal protective stands.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 31 July 2020
Resolution: New generator fuel line has been installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 July 2020
Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). The starboard bottom life line and the port top life line are chafed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 July 2020
Resolution: Stbd bottom and port top life lines replaced in-kind.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2020
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The port and starboard inferior shroud tang has an approximate 1/2 inch linear defect/crack along the inner bend.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 16 July 2020
Resolution: Tang suspected crack/defect was investigated and determined to not be an issue.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 July 2020
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The port railing 5th station support bar weld and the starboard railing 2nd station support bar weld are cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 18 August 2020
Resolution: The railing station support bars have been repaired to acceptable standards.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 July 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 5 August 2020
Resolution: Received photo of functional VHF Lat/Long.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 July 2020
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The magnetic compass light is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 11 August 2020
Resolution: Magntic compass lightblub replaced in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2019
Resolved
Provide rotating machinery cover for stbd engine. An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 18 October 2019
Resolution: Vessel installed rotating machinery guard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2019
Resolved
Replace net support lines for forward nettings. The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for intended service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2019
Resolved 2 October 2019
Resolution: Replaced with new lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2019
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 meet in length, but not more than 6 feet. Renew lanyard for waterlight. 46 CFR 180.70((d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Waterlight lanyard renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 June 2019
Resolved
Each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. Renew retroreflective tape on lifefloats. 46 CFR 185.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Retroreflective tape on lifefloats renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 June 2019
Resolved
A vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Chart is updated to 2017. Provide updated chart for operating area. 46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Vessel rep provided updated chart for operating area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2018
Resolved
Fuel shut off valves were marked inside cabinet. Label fuel shut off valves on both port and starboard side on the outside of the cabinets. IAW 46CFR185.605
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 23 July 2018
Resolution: Received pictures from master with visual labeled fuel shut offs. All sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 June 2017
Resolved
Waterlight was missing; required to provide waterlight with lanyard and corrosion resistant clip IAW 46 CFR 180.70(d).
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: Vessel owner provided picture of waterlight onboard.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 19 June 2017
Resolved
Vessel's red hand flares did not meet were not marked with Q spec approval 160.021; required vessel to have appropriate red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q or other standard specified by the Commandant. 46 CFR 180.68(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 22 June 2017
Resolution: Vessel provided 8 new red hand flares approved in accordance with 46 CFR 160.021 in Subchapter Q.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 8 April 2016
Resolved
Vessel waste management plan not onboard or available for viewing, required vessel provide waste management plan for verification IAW 33 CFR 151.57
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: New waste management plan posted.
Lifesaving › Lifefloat › Float Free
Issued 8 April 2016
Resolved
Lifefloats stowed in a stacked position without a spacer between as required by 46 CFR 180.137(f)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: Spacers installed between life floats.
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 April 2016
Resolved
Lifefloat retro-reflective tape was unserviceable, required to replace IAW 46 CFR 185.604 (h)(i)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: Unservicable retro tape was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 April 2016
Resolved
Attached floating electrical waterlight operated intermittently, required to provide light IAW 46 CFR 180.175 (f)(4)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: New float light purchased.
Lifesaving › Lifebuoys › Serviceable
Issued 8 April 2016
Resolved
Life rings onboard were cracked and unserviceable IAW 46 CFR 180.70(a)(2)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: New ring buoy purchased.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2016
Resolved
Port side navigation light damaged, light casing attached to hull with tape, navigation lighting needs to be attached IAW manufacturer specifications and operational IAW 46 CFR 183.200
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 2 May 2016
Resolution: New nav light purchased and installed.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 25 February 2016
Resolved
Replace all water cooled strut bearings in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2016