MAURY USCG vessel records
← All vessels

PUNTA

PUNTA is a 2013 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in July 2024, along with 8 deficiencies and 4 operational controls.

Records from 2016 to 2024. Most recent: operational control imposed, 5 July 2024.

Built
2013
Last inspected
5 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9606118
V7A5952
1274682
Flag
MARSHALL ISLANDS
Maury page id
psix-1274682

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded6
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it62326 - Displacement, Metric Ton
51890 - Dead Weight, Metric Ton
30092 - Convention (Subpart B), Gross Ton
17831 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 18

5 July 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7949726
2 April 2024 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7883877
10 November 2022 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 7655723
3 November 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7588607
3 November 2022 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7588866
29 July 2021 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7271439
4 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7244403
1 July 2021 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7236268
8 January 2018 ISPS II Exam · Ballast Water Examination · COE-Dockside · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6332956
22 November 2017 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6311622
17 November 2017 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6308776
16 November 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6307156
15 February 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089289
15 February 2017 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089293
9 February 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6085700
4 November 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6035130
4 November 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6035229
28 October 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6031418

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2021 Resolved
The function of fixed fire detection systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. Vessel did not have a heat testing lamp available for testing fire detection system. -74SOLAS(20)II-2/7.3.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 29 July 2021
Resolution: VESSEL PROVIDED VIDEO AND CLASS REPORT TO RESOLVE SAID DEFICIENCY, ALL SAT.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 January 2018 Resolved
1740 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention. PSCO observed the oil content meter displaying an error stating that the desiccator needs to be replaced. MARPOL Annex I/6 - 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2018
Resolution: PSC NOLA received a class report from Croatian Register of Shipping satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 8 January 2018 Resolved
0635 - Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops. PSCO observed the limit switch on the rescue boat davit arm was not functional. 74 SOLAS (2014 Amm.) III/34 - LSA Code 6.1.2.7 - 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 January 2018
Resolution: Limit switch was repaired prior to the completion of the exam.
Lifesaving › Lifeboat › Propulsion Engine
Issued 8 January 2018 Resolved
0610 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the lifeboat engine could not continuously run. 74 SOLAS (2014 Amm.) III/20.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 January 2018
Resolution: Crew changed out the fuel filter and the lifeboat engine ran properly prior to completion of the exam.
Lifesaving › Launching Appliances › Falls
Issued 8 January 2018 Resolved
0635 - Falls used in launching shall be inspected periodically with special regard for areas passing through sheaves. PSCO observed that the rescue boat davit winch sheave was not rotating while raising and lowering the rescue boat. 74 SOLAS (2014 Amm.) III/20.4 - 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 January 2018
Resolution: Crew greased the sheave and corrected the deficiency prior to completion of the exam.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 November 2016 Resolved
PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM THE HEAT RADIATING FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. THE OUTER SHELL OF BOTH FIREMAN'S OUTFITS HAVE SEPERATED FROM THE SUITS, NOT PROVIDING THE PROTECTION AS DESIGNED.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2016
Resolved 10 November 2016
Resolution: Purchased new Fireman's suits, visually verified that suits were in good working condition.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 7 November 2016 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. THE VESSEL HAS A JACKET WATER LEAK NEAR PISTON NUMBER ONE.
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 10 November 2016
Resolution: Verified repair was in good condition and not leaking.
Navigation › Piloting/Steering › Swing Meter
Issued 7 November 2016 Resolved
ALL SHIPS OF 500 GT AND ABOVE SHALL HAVE RUDDER PROPELLER, THRUST, PITCH, AND OPERATIONAL MODE INDICATORS, OR OTHER MEANS TO DETERMINE AND DISPLAY RUDDER ANGLE TO BE READ FROM THE CONNING POSITION. THE RUDDER ANGLE INDICATORS ON THE BRIDGE WINGS ARE INOPERABLE AND READING BETWEEN 10 AND 20 DEGREES OFF TO STARBOARD.
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 10 November 2016
Resolution: Verified Bridge wing Rudder angle indicators matched the reading at the main steering position in the bridge house. All Sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.