HANNAH NICOLE is a 1974 towing vessel. The Coast Guard has recorded 21 inspections since 1985, most recently in April 2026, along with 12 deficiencies and 1 operational control.
Records from 1985 to 2026. Most recent: inspection, 23 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)55.5 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 72 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEELSHIP CORPORATION · PINE BLUFF, AR, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJEFFERSON CITY, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Gross Ton 49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port generator mounting bolts loose. Ensure proper hardware is installed and torqued in accordance with manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2021
Resolution: Bolts tightened. One bolt was found to be broken. Replaced
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 21 October 2021Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Vessel has not conducted required drills before operations. Conduct training and drills as required for this vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2021
Resolution: Drills conducted and logged as required.
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Multiple deck hatches not marked. Correct as required.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2021Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Generator starter wiring not marine rated (Welding cables). Replace cables with required type.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 October 2021Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. In areas where space limitations make deck rails impractical, such as at narrow catwalks in way of deckhouse sides, hand grabs may be substituted. Stern of vessel is not equipped with rails. Install rails as required.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2021Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable and combustible products being stored in front shop space. Store product in cabinet as required.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2021Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Electrical outlet on starboard tow knee missing waterproof cover and is not GFI rated. Remove and install proper outlet suitable for outside/wet environment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 21 October 2021Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. Electrical cables running through engine room from front shop space compromise water tight / fire boundary. Seal bulkhead as required.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 October 2021Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be automatic, battery-operated with a duration of no less than 2 hours. Emergency lighting in engine room inoperable. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to slips, trips and falls. Front shop space above engine room has an unsound deck with wasted metal being covered by rubber/plastic material. Crop out wasted metal to good material and repair to original condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2021Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Deadend wire found in shop overhead. Remove wire.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 14 October 2021Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to slips, trips and falls. Forward void ladder wasted. Replace ladder.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2022
Resolution: Corrected to the satisfaction of TPO
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.