Records from 2016 to 2026. Most recent: inspection, 12 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 28
12 May 2026
Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8368755
29 March 2026
Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8333976
29 March 2026
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8453597
19 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8118670
30 April 2024
Examination of Repairs · Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7903838
8 February 2024
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853988
5 October 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806727
18 July 2023
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7746808
9 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7648741
3 February 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7631680
23 February 2022
Deficiency Check · Construction Oversight · Internal Structural Exam · Plan Review "T" Boat · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7400931
19 November 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7379995
15 April 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7176143
4 March 2021
Examination of Repairs · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7152331
6 February 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7141867
4 November 2020
Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7089905
11 September 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7058444
18 February 2020
Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6911818
1 March 2019
Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6634413
20 November 2018
Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6583982
4 June 2018
Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6563627
21 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294353
11 July 2017
Administrative Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6362020
8 May 2017
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 6145800
8 May 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6315850
20 December 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6096571
25 May 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5882107
14 January 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5797960
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 May 2026
Resolved
Fire boy system not working correctly. issued CG-835 17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2026
Resolved
Replace port engine raw water line,leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2026
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 May 2026
Resolved
Port side F/O shut off not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2026
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 May 2026
Resolved
High water alarms need to be labeled at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 May 2026
Resolved
No drills will be conducted today.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2026
Resolution: Drills have been conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2025
Resolved
During test of the installed fire control system the system did not work properly. Repair/renew system to working order.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 May 2025
Resolved
15 person life float needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2025
Resolved 16 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2025
Resolved
STBD F/O shutoff value does not close completely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 16 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2025
Resolved
Fire buckets need to be labeled correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 22 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2025
Resolved
Ring buoy needs vessel name on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 16 June 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2025
Resolved
Anchor light does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 16 June 2025
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 May 2025
Resolved
Missing FCC station license on vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2025
Resolved 16 June 2025
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 May 2025
Resolved
Missing FCC operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2025
Resolved 16 June 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2024
Resolved
Failure to conduct drydock and internal structural inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2024
Resolved 15 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024
Resolved
Fuel lines from tank to racor filters on both engines are not on the CG approved hose list. All fuel, oil, and hydraulic hoses must meet the J1942 standard and be on the CG approved hose list. Replace both hoses from tank to racor filters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 10 April 2024
Resolution: Hoses were inspected and verified to comply with the approved Qualified Hoses for Marine Applications list, published on Decemeber, 2018.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 February 2024
Resolved
Oil lines on transmission to cooler on both engines are not on the CG approved hose list. All fuel, oil, and hydraulic hoses must meet the J1942 standard and be on the CG approved hose list. Replace all 4 transmission oil hoses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 10 April 2024
Resolution: Hoses were inspected and verified to comply with the approved Qualified Hoses for Marine Applications list, published on Decemeber, 2018.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2024
Resolved
Two type 2 adult life jackets were found on board. Must replace with 2 adult type 1 life jackets as required. Reduced passenger count by 2 until cleared.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2024
Resolved 8 February 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 July 2023
Resolved
02 rail posts were found deformed and mounting plates dislodged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 17 August 2023
Resolution: Full replacement of stanchions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2023
Resolved
Automatic bilge pumps must have visual indicators when pumps turn on. High water alarms must have both audible and visual indicators for each alarm. All 3 bilge pumps and high water alarms are tied into the main diesel engine display and is not communication with the display. No way to know when a high water alarm sounds or when a bilge pump kicks on. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 March 2023
Resolved
Fire boy system will shut down the engines, but will not all the engines to start after hitting the override. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 15 March 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 March 2023
Resolved
One of the portable lights was not working. Must have 2 portable lights. Make repairs or replace and to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 15 March 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 9 March 2023
Resolved
Vessel does not have any load marks. Must place load marks in accordance with stability letter.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2023
Resolved 6 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2022
Resolved
1 of 3 Fire extinguishers was expired. Must replace or have annual servicing completed prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Owner/ Operator provided documentation of the servicing of 02 fire extinguishers and the purchase of 04 fire extingishers. 01 expired extinguisher replaced on the vessel. Vessel cleared to operate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022
Resolved
Due to the capacity of both new life floats (12 passenger count each) total people onboard (crew and passengers) can not exceed 48 until larger life floats are provided to meet the required 50 percent total onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 April 2022
Resolution: vessel has one 12 passenger float and one 15 passenger float on board and properly labeled.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 April 2022
Resolved
Hydrostatic release on the EPIRB expired March 2021. Must replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 21 May 2022
Resolution: Received photographic image of recently purcased and installed hydrostatic release for EPIRB.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 28 April 2022
Resolved
Captains chair is broken and hanging on by 1 bolt and about to break off. Must make repairs for the safety of the Captain
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 21 May 2022
Resolution: Received viseo footage of recently installed captain's bench on the fly-bridge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 February 2022
Resolved
Company failed to notify of this vessel was hauled out of the water for a repower. Company must submit info on repower, conduct engine alarm testing and satisfactory sea trials prior to carrying passengers.
46 CFR 176.700
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2022
Resolution: Conducted satisfactory MDE testing and sea trials
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2021
Resolved
STBD life float light not flashing properly. Must conduct repairs or replace light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2021
Resolved 9 March 2021
Resolution: STBD life float light was replaced with a functional spare. All float lights retested to ensure all lights were functional.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 March 2021
Resolved
Life lines on both Life floats are dry rotted. Must replace life lines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 9 March 2021
Resolution: replaced life float grab lines
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 March 2021
Resolved
Engine guards are missing on both MDE's. Must replace guards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 9 March 2021
Resolution: Both engine guards were placed and properly secured to mounting studs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 February 2020
Resolved
Deck drain is missing hose. This leaves an opening in the hull. Renew hose or blank off through hull fitting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2020
Resolution: A new plastic fitting was added to the deck and replaced the drain hose.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 February 2020
Resolved
Crack in tank space must be inspected by fiberglass expert.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2020
Resolution: The crack in the hull was ground out, filled with epoxy, and added a layer of fiberglass and paint.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 February 2020
Resolved
Lazarette hatch gasket must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2020
Resolution: Lazarette hatch was repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 February 2020
Resolved
VHF must have GPS input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2020
Resolution: GPS input was verified in the VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 February 2020
Resolved
Bottom life float reflective material is wasted. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2020
Resolution: Bottom life floats reflective tape was renewed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 February 2020
Resolved
Add abandon ship drill to electronic log.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2020
Resolution: Electronic logs were updated to include abandon ship drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2019
Resolved
09 adult lifejackets are incorrect type are wasted. Renew prior to carrying more than 43 persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: Renewed
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 1 March 2019
Resolved
Pre-engineering fire system head unit visual alarm is extinguished, and audible alarm is weak. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: Repaired/Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2019
Resolved
Renew reflective tape on both life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2019
Resolution: New reflective material was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2018
Resolved
Life ring is not servicable and must be renewed.
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: New life ring was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2018
Resolved
7 adult PFDs are no longer servicable and must be renewed. The vessel is restricted to no more than 45 adult passengers until the PFDs are replaced.
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: 7 new PFDs were provided, marked and placed into service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2018
Resolved
First aid kit is missing contents and must be replaced or have contents renewed Per CFR.
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: New CG approved first aid kit was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2018
Resolved
Hardware on the steering system is loose. Repair/renew hardware.
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: All steering hardware was renewed, tested all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 July 2017
Resolved
bilge alarm system in inoperable. Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2017
Resolution: Bilge system alarms were corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2017
Resolved
Stern light is extinguished. Repair.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 11 July 2017
Resolution: Nav light bulb was replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 11 July 2017
Resolved
reflective material is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 18 July 2017
Resolution: New tape was applied.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 11 July 2017
Resolved
Vessel is missing the waste management program.
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 18 July 2017
Resolution: Plan was provided and posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 July 2017
Resolved
Vessel is missing emergency instructions. provide and post.
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 18 July 2017
Resolution: Plan was provided and posted.