FAST SERVER is a 2014 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 21 deficiencies.
Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
- Built
- 2014
- Last inspected
- 26 May 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1252972
9718246
WDH5198
1275275
Flag
UNITED STATES
Maury page id
psix-1275275
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)174.4 ft × 32.0 ft × 14.0 ft
ITC tonnagegross 491 / net 147
BuilderBREAUX BROTHERS INC · LOREAUVILLE, LA, UNITED STATES · built 2014
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
491 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
147 - Convention (Subpart B), Net Ton
491 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
147 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
26 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8323075
24 October 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8264591
29 May 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8147081
15 May 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8148521
1 August 2023
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7757607
10 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7529663
17 June 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7480285
20 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7316747
9 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7109240
12 August 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7030741
17 June 2020
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6978923
3 April 2020
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6935199
20 June 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6719498
29 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6525680
11 June 2018
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6441345
16 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6242811
23 August 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5981181
28 June 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5922760
Deficiency record · 21
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 June 2025
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. No Marine Radio Operator Permit as per 47 CFR 80.159(e)(1) on board. Supply permit for master/mate on board.
46 CFR 184.502
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 June 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. No current COD on board, only expired. Had a copy emailed. Supply original on board.
46 CFR 67.313(a)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2025
Resolved
An interconnected detection and alarm system must be installed such that the activation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c)/46 CFR 118.400(d). No visual/audible in crew accommodations. Company has an appeal for other vessels in its fleet, correct when fleet has appeal decision.
46 CFR 181.450(a)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Had extension cord spliced through wood bulkhead. Crew secured power, cut cord, and removed.
46 CFR 183.200(b)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 June 2025
Resolved
Standby vessels must have, at least, the following equipment: a fire monitor with a minimum flow rate of, at least, 500 gallons per minute. Company removed monitors and pumps to be worked on. Can not do standby service until system is installed and verified working.
33 CFR 143.405(a)(12)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2023
Resolved
Found steering system leak, fluid entering pump electric motors. Must be within OCMI deemed good marine practice. Repair/replace/maintain.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2023
Resolved
Loose, dead end, non-permanent wiring on fwd hydraulic resevoir. Must be OCMI deemed good marine practice. Repair/replace/make permanent.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 1 August 2023
Resolved
Found OWS Smart Cell calibration certificate out of date os of SEP 2023. Onboard filtering equipment must be certificated as calibrated. Usage is restricted until calibrated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2022
Resolved
Vesel must have independent rudder angle indicator at the operating station. Rudder angle indicator found inoperable past 5* at emergency steering station. Repair / replace.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 August 2020
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead.
03 watertight doors were observed to have active air flows coming through their sides when closed and the quick action closing device was secured, compromising the watertightness of the bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2020
Resolved
A vessel's hull must not carry current as a conductor.
Vessel's ground fault detection alarm indicated a fault, that was isolated to the vessel's aft floodlights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2020
Resolved
All cable and wire must be installed with metal supports not spaced more than 24 inches apart... plastic tie wraps must be limited to bundling or retention and not used as a means of support.
Vessels electrical cables, installed for the portable accommodation module, were only supported by plastic tie wraps, bound to the existing cable installations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2020
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet in length.
The lanyard securing the floating waterlight to the ring life buoy was in excess of 6 feet in length. (60 FT)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with an equivalent contents and instructions.
Vessels first-aid kit had medication in it that expired back in July and was unable to meet the content requirements of the 160.041 approval series.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2020
Resolved
USCG approved modules S/N MQ07KM20L0168 installed 03Apr2020 may remain onboard an in operation for 180 days from inspection. Vessel stability has been verified by ABS and MSC. Additional lifesaving and firefighting equipment and installations shall remain onboard until proper removal of these modules are verified by an attending marine inspector.
46 CFR 175.550
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2020
Resolved
USCG APPROVED MODULES S/N: MQ07KM20L0168 INSTALLED 03APRIL2020 INCREASED THE VSL'S TONNAGE FROM 93GRT TO 116GRT (24%) WHICH IS OUTSIDE THE APPLICABILITY OF SUBCHAPTER-T SERVICE. THE ABOVE MODULE MAY REMAIN ONBOARD AND IN OPERATION SO LONG AS THE HOST VSL MEETS SUBCHAPTER-H SERVICE. IF THE HOST VSL ELECTS NOT TO MEET SUBCHAPTER-H SERVICE THE AFFOREMENTIONED PAM MODULE MUST BE REMOVED WITHIN 30 DAYS.PROPER REMOVAL OF THIS MODULE SHALL BE VERIFIED BY AN ATTENDING MARINE INSPECTOR. 46 CFR 175.550
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 April 2020
Resolved
USCG APPROVED MODULES S/N: MQ07KM20L0168 INSTALLED 03APRIL2020 MAY REMAIN ONBOARD AND IN OPERATION FOR 60 DAYS TO FACILITATE ONGOING DISCUSSION REGARDING CG DETERMINATION FOR SUBJECT VESSEL. VESSEL STABILITY HAS BEEN VERIFIED BY ABS AND MSC. ADDITIONAL LIFESAVING AND FIREFIGHTING EQUIPMENT AND INSTALLATIONS SHALL REMAIN ONBOARD UNTIL PROPER REMOVAL OF THESE MODULES ARE VERIFIED BY AN ATTENDING MARINE INSPECTOR.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 June 2019
Resolved
A crack was located on the top of the rail located on the starboard side amidships
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2019
Resolved
vessel had missing fuses on the sound powered phone/ siren/beacon assembly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2019
Resolved
vessel had a clamp missing on the high pressure fuel line on the main diesel engine
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2019
Resolved
Inspector located loose wiring on the pressure limit switch attached to the pressure vessel