MAURY USCG vessel records
← All vessels

INUYAMA

INUYAMA is a 2009 public freight. The Coast Guard has recorded 5 inspections since 2016, most recently in September 2025, along with 1 deficiency.

Records from 2016 to 2025. Most recent: inspection, 30 September 2025.

Built
2009
Last inspected
30 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 September 2025
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9392080
1275283
Flag
PANAMA
Maury page id
psix-1275283

Documentation record

Tonnage as PSIX records it19922 - Dead Weight, Metric Ton
26126 - Displacement, Metric Ton
13668 - Convention (Subpart B), Gross Ton
6537 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

30 September 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8243890
17 September 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8236039
19 September 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6267092
18 September 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6269357
6 August 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5956470

Deficiency record · 1

Construction/Loadline › Structures › Superstructure
Issued 20 September 2017 Resolved
After any survey of the ship, no change shall be made in the structural arrangements. Ship’s crew fabricated and installed wooden bulkheads to create storage room on upper deck, port side aft in vicinity of provisions storage to engine casing and would provide no documentation of installation and room is not indicated on general arrangement or fire control plan.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 17 September 2025
Resolution: PSC NOLA received a class report documentation from issuing entity satisfying the requirements.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.