Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)37.2 ft × 11.5 ft × 3.9 ft
Registered tonnagegross 12 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRAFTON · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT OF ST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 July 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Gross Ton 8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
24 July 2025Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8166378
8 October 2024Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8009612
19 September 2023Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7784950
15 September 2022Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7549141
8 July 2021Initial Certification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7160964
20 November 2020Special Consideration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7100930
14 November 2019Uninspected Other · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6834560
5 June 2018DAPI Audit · Administration · Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6431323
12 September 2017Deficiency Check · Administration · Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6264166
17 November 2016Spot Check (Safety) · Administration
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6050038
10 November 2015Industry Initiated Exam · Administration
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5760806
12 November 2014Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5021952
17 October 2011Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4170750
3 November 2010Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3885431
27 October 2009Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3622448
15 January 2009Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3394849
4 November 2008Administrative Inspection · Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3358307
4 October 2007Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3076113
26 June 2005Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2403271
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 September 2022Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Kit not on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 26 September 2022
Resolution: New first aid kit placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 July 2021Resolved
Vessel required to have means for closing openings into machinery spaces. Engine room had several openings with insufficient or no means to close. Equip vessel with means to close all openings.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: All openings identified were permenantly closed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021Resolved
Towing light required to have an arc of horizon of 135 degrees. Light lens was obstructed with paint reducing arc of visibility. Restore light's arc of visibility to 135 degrees.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Towing light lense cleaned of paint and arc restored.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2021Resolved
Vessel required to be fitted with a whistle capable of producing prescribed blasts. Vessel's whistle failed to operate. Prove proper operation of the vessel's whistle.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Whistle replaced and crew demonstrated proper operation of vessel's whistle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2021Resolved
Vessel required to be fitted with 2 lifebuoys and 2 water lights. Vessel only fitted with 1 lifebuoy and water light. Properly fit vessel with prescribed number of lifebuoys and water lights.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Second lifebuoy and water light placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2021Resolved
Vessel required to be fitted with one fire axe. Axe was not on board vessel. Outfit vessel with a fire axe.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Fire axe installed on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 8 July 2021Resolved
Emergency lighting required for all internal crew working areas. Vessel not fitted with emergency lighting. Install emergency lighting (or non-electric, phosphorescent adhesive lighting) along escape routes.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: Non-electric, phosphorescent adhesive lighting installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2021Resolved
Gaskets required to be maintained to prevent leaks of combustible liquids. Hydraulic controller valves (port & starboard) leaked (two slow drips) hydraulic oil passed installed gaskets/seals during operation. Properly repair controller valves to secure leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 August 2021
Resolution: Hydraulic controller valves rebuilt; seals renewed, which secured leaks.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.