OSCAR B is a 2014 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in March 2026, along with 19 deficiencies and 2 casualty investigations between 2018 and 2025.
Records from 2016 to 2026. Most recent: inspection, 24 March 2026.
- Built
- 2014
- Last inspected
- 24 March 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2018–2025
Identity
1251592
WDH7993
1275518
Flag
UNITED STATES
Maury page id
psix-1275518
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2016–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)109.2 ft × 47.5 ft × 6.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)109.2 ft × 47.5 ft × 6.0 ft
ITC tonnagegross 198 / net 62
BuilderICE FLOE LLC · FREELAND, WA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPUGET ISLAND, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Gross Ton
62 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
76 - Regulatory (Subpart C or D), Gross Ton
62 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 28
24 March 2026
DAPI Audit · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8331290
4 September 2025
Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8227379
9 April 2025
Hull Examination · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8108855
19 March 2025
Drydock Extension
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8096135
28 February 2025
In-Service Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8087359
19 February 2025
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8086221
24 January 2025
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8069460
18 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7897326
19 February 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7867279
2 March 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7643885
28 February 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7403150
30 August 2021
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7300636
3 August 2021
Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7283088
17 February 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7144299
13 March 2020
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6927214
25 February 2020
Drydock Extension
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6915626
4 February 2020
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6890793
25 June 2019
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6727774
6 February 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6628925
5 April 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6783301
15 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6355873
7 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6168461
25 May 2017
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6160275
15 February 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6088435
14 December 2016
Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6058502
9 February 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5811942
5 February 2016
Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5811333
7 January 2016
In-Service Inspection · Examination of Repairs · Plan Review "T" Boat
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5797068
Deficiency record · 19
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2023
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew was unfamiliar with bilge system when asked to test capability. Drills were unable to be conducted at time of inspection. Have all captains and crew members demonstrate proficiency in drills and use of emergency systems to USCG marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 March 2023
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main. Unable to find/test bilge high water alarms. Submit plans for high water alarm installation for CG approval.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 2 March 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Testing of the fire detection system detectors were unable to be performed at inspection. Provide proof of testing for fire detection system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2023
Resolved
If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. The portable fire extinguishers appeared to have been annually serviced, but incorrectly dated on tags. Provide accurate proof of portable fire extinguisher annual servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2023
Resolved
A vessel of more than 65' in length must carry a minimum of 03 life buoys of not less than 24" in diameter. A vessel must carry one floating waterlight. Ring life buoy on the bridge has excessive wear and inoperable waterlight. Replace ring life buoy and repair or replace waterlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. Remote fuel shutoff valve has no marking. Mark fuel shutoff valve.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 March 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Missing Coast Pilot and Light List. Provide updated navigation publications on board vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 February 2021
Resolved
Provide simple instructions for the operation of the CO2 fixed fire extinguishing system at or near the pull box. 46 CFR 185.612
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 February 2021
Resolved
Provide adequate and up-to-date charts and nautical publications (U.S. Coast Pilot 10, Coast Guard Light List Vol. VI). Update electronic charting software as needed. 46 CFR 184.420
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2021
Resolved
Attach the floating waterlight to the ring buoy with a corrosion-resistant clip. 46 CFR 180.70(d)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2021
Resolved
Replace faded lifebuoy on deck. 46 CFR 180.70(b)(5)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 February 2021
Resolved
At next dry-docking, crop and renew inset (4 ft long) on side shell hull plating above waterline at port stern. 46 CFR 177.300 (b)(2)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 February 2021
Resolved
At next dry-docking, verify port rudder post through hull penetration does not require repairs due to minor leaking observed in 2020.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 February 2018
Resolved
Vessel was missing life jackets as required by COI for (2) adults (100 on board) and (1) child (10 on board). Vessel is restricted to 98 passengers.
Engineering › Steering Gear System › Power Unit
Issued 25 May 2017
Resolved
DC01: Identify cause of rudder failure, fix rudder and perform underway trials to the satisfaction of attending Marine Inspector prior to carrying passengers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 February 2016
Resolved
Fixed gas fire extinguishing system needs to be annually serviced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 February 2016
Resolved
Provide proper "key" for the remote fuel shut-off on deck.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 February 2016
Resolved
Label remote fuel shut-off on deck.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 February 2016
Resolved
Replace port and starboard aft emergency lights.
Casualty record · 2
5 April 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6783301
19 February 2025Routine · role: Involved in a Marine Casualty · activity 8086221
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.