Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it25932 - Dead Weight, Metric Ton 32787 - Displacement, Metric Ton 14750 - Regulatory (Subpart C or D), Gross Ton 7993 - Regulatory (Subpart C or D), Net Ton 7993 - Convention (Subpart B), Net Ton 14750 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 10
30 January 2024COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7853160
24 February 2022PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7398292
18 December 2020PSC B · COC-CHEM & TVE Annual
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7108290
5 December 2019ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6860604
18 April 2018Ballast Water Examination · Administrative Inspection · ISPS II Exam · Deficiency Check · COC-CHEM & TVE Renew
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 18 April 2018Resolved
1160: The vent outlet hight may be reduced to 3m above a raised walkway, provided that high velocity venting valves direct the vapour/air misture upwards with an exit velocity of at least 30m/s. High velocity vent outlets for all port side cargo tanks are within 3m of the lower catwalk, portside. IBC 8.3.5. 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2018
Resolved 23 June 2018
Resolution: Received proper documentation from class NKK that the vessel blanked off the PV valves in question.