Records from 2017 to 2026. Most recent: inspection, 8 July 2026.
Documentation record
Registered dimensions (L × B × D)587.1 ft × 105.6 ft × 62.7 ft
Registered tonnagegross 29,923 / net 12,581
ITC dimensions (L × B × D)587.1 ft × 105.6 ft × 62.7 ft
ITC tonnagegross 29,923 / net 12,581
BuilderNATIONAL STEEL AND SHIPBUILDING COMPANY · SAN DIEGO, CA, UNITED STATES · built 2017
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 June 2026 · expires 30 June 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29923 - Convention (Subpart B), Gross Ton
49045 - Dead Weight, Ton
12581 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
8 July 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8433241
4 May 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8362036
18 August 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8210865
3 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042856
29 August 2024
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7986391
12 August 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7979940
30 July 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7970334
5 December 2023
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7870144
1 August 2023
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7740512
3 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7661846
15 July 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7507443
8 June 2022
Administrative Inspection · Re-Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7471895
2 June 2022
COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7466594
3 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7424874
27 July 2021
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7222581
16 November 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7096022
24 July 2020
MTSA/ISPS Verification · ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7014999
8 April 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6937435
9 July 2019
MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6733709
20 February 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6628695
26 November 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6587345
25 July 2018
ACP Annual Oversight · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6464482
7 December 2017
COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6320177
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2025
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. Grounding wire connected to deck water seal had spliced connection with electrical tape that requires repair.
74 SOLAS (14) II-1/45.11
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 29 August 2025
Resolution: ACS accepted and confirmed correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2025
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. Multiple extension cords connected to lighting in the engine room that require permanent wiring installations.
74 SOLAS 14 II-1/45.5.6
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 29 August 2025
Resolution: ACS accepted and confirmed correction.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 August 2025
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Ships port side load line markings found faded no longer contrasting color to the hull.
ICLL(66) I/8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 29 August 2025
Resolution: ACS accepted and confirmed correction.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 August 2025
Resolved
Where "B" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for the fitting of ventilation terminals, lighting fixtures and similar devices, arrangements shall be made to ensure that the fire resistance is not impaired, subject to the provisions of paragraph 7.3.2. Cable penetration on the A deck within the cable trunk found missing section of fire stop.
74SOLAS (14) II-2/9.3.3.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 August 2025
Resolution: Crew corrected in presence of MI by applying fire retardent material.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 8 April 2020
Resolved
Vessel's S-band radar is inoperable.
74SOLAS(14) V Reg.19.2.7.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2020
Resolved 8 April 2020
Resolution: Received a report from [name withheld] attesting to the repair of the S-band radar.