MAURY USCG vessel records Sign in
← All vessels

Q DEB

Q DEB is a 2014 freight ship. The Coast Guard has recorded 1 inspection in 2016, along with 1 deficiency.

Records in 2016. Most recent: inspection, 11 January 2016.

Built
2014
Last inspected
11 January 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9678484 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1276410
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1276410

Inspections, by type

Years with a record 1 calendar year (2016)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it28127 - Convention (Subpart B), Net Ton
84970 - Dead Weight, Metric Ton
98636 - Displacement, Metric Ton
47003 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

11 January 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5791249

Deficiency record · 1

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 January 2016 Resolved
1735 - Pumping discharge arrangements - The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During test of the OWS system, PSCO observed water overflowing from the recirculation line funnel into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 15 January 2016
Resolution: Received, reviewed and accepted class report from ABS stating the deficiency regarding the OWS was rectified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.