NATURE SCHOOL II

NATURE SCHOOL II is a 2014 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in October 2025, along with 21 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 7 October 2025.

Built
2014
Last inspected
7 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH7101
1276434
Flag
UNITED STATES
Maury page id
psix-1276434

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

7 October 2025 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8253335
3 September 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8226581
25 July 2024 Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7961634
5 October 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7804324
26 January 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7133145
30 July 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7020307
27 May 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6962028
11 February 2020 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6907103
27 January 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6908066
15 January 2020 COI Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6883852
26 April 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6670601
30 January 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6617472
17 April 2018 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6393479
11 April 2017 Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6141864
26 January 2017 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6078016
1 May 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5915957

Deficiency record · 21

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 May 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except duringan emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alterations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of the T-Top alterations to the cognizant [name withheld] to the addition of the T-Top without approved plans it should be removed or a new stability test must be conducted prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2020
Resolution: Vessel operator provided photographic evidence of the canopy removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 January 2020 Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must have a ventilation system that complies with this section. The vessel was found to have an inadequate ventilation system for a vessel containing gasoline independent fuel tanks in an enclosed space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 11 February 2020
Resolution: Marine Inspector verified proper ventilation system installation on vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 January 2020 Resolved
Electrical equipment in spaces, compartments, or enclosures that contain machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 degrees C (110 degrees F) or lower must be explosion-proof, intrinsically safe, or ignition protected for use in a gasoline atmosphere as required by 183.530 of this chapter. The vessel's starter batteries are located in a continuous compartment that also houses the gasoline fuel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 27 January 2020
Resolution: Marine Inspector verified proper installation of batteries outside of the enclosed space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2020 Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. The vessel was unable to conduct the exterior "leak" test IAW Sector Honolulu Work Instruction 07 due to not providing the manufacturer's specified maximum allowable working pressure. Subsequently, drills were not conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 27 January 2020
Resolution: Marine Inspector coducted successful exterior "leak" test IAW Sector Honolulu's Work Instruction 07.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2020 Resolved
Each ring life buoy on a vessel must be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The ring life buoy was found to be damaged and its grab lines to be brittle due to uv damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 11 February 2020
Resolution: Marine Inspector verified new ring life buoy onboard vessel.
Lifesaving › Hand Flares › Expired
Issued 17 April 2018 Resolved
Vessel needs to replace all expired distress signals. In accordance with 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 26 April 2018
Resolution: The vessel replaced all expired flares.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 April 2018 Resolved
Vessel needs to have onboard the proper type portable fire extinguisher as required by the vessel's COI. In accordance with 46 CFR 181.500.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: The vessel replaced the fire extinguishers onboard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 April 2018 Resolved
Vessel needs to provide a visual indicator for the onboard bilge pump as required in 40 CFR 182.520.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 1 May 2018
Resolution: The vessel replaced the inoperable bilge visual indicators.
Communications › Alarms/Indicators › High Water Alarm
Issued 17 April 2018 Resolved
Vessel needs to provide a visual indicator for the onboard high bilge alarm as required in 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 1 May 2018
Resolution: The vessel replaced the inoperable high water alarms.
Lifesaving › Lifebuoys › Serviceable
Issued 17 April 2018 Resolved
Vessel needs to replace the life buoy detachable clip with a metallic non-corrosive clip as required in 46 CFR 180.70 d (3).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 26 April 2018
Resolution: The vessel replaced the life buoy clip with a metallic one.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 17 April 2018 Resolved
Vessel needs to provide a bight watertight container for its onboard distress signals and label the container as "Emergency Distress Signals" as required in 46 CFR 185.614.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 26 April 2018
Resolution: The vessel replaced and labelled the distress signals container accordingly.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 April 2018 Resolved
Vessel needs to post emergency procedures for rough water and unresponsive snorkeler as required by 46 CFR 185.510.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: The company posted emergency procedures onboard the vessel.
Fire Fighting › Fire Bucket › Availability
Issued 17 April 2018 Resolved
Vessel needs to attach lanyards long enough to pick up water from vessel on all fire buckets as required in 46 CFR 181.610.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 26 April 2018
Resolution: The company placed new fire buckets with line attached onboard the vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 April 2017 Resolved
Vessel needs to have its portable fire extinguishers replaced with two valid B-II fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 19 April 2017
Resolution: Vessel provided proof of new fire extinguishers.
Communications › Radio Communications › EPIRB
Issued 11 April 2017 Resolved
Vessel needs to replace the EPIRB release unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: Vessel outfitted a new hydrostatic release unit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017 Resolved
Vessel needs to install 3 to 6 feet of line with a non-corrosive metallic clip to the vessels float water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: Vessel outfitted a new line with a non-corrosive clip.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 April 2017 Resolved
Vessel needs to stencil vessel name on ring buoy.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: The vessel name was stenciled on the ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 April 2017 Resolved
Vessel needs to label two child lifejackets at the location where the child lifejackets are stowed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: The child lifejacket location was marked.
Documentation › Certificates/Documents › Permit, Other
Issued 11 April 2017 Resolved
Vessel operators need to provide proof of holding a valid FCC Marine Radio Operator Permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 19 April 2017
Resolution: The vessel provided proof of a valid FCC Marine Radio Operator Permit.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 April 2017 Resolved
Vessel needs to update its emergency instruction list to incorporate in water emergencies.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: The vessel updated and posted its procedures for in-water emergency.
Fire Fighting › Fire Bucket › Stenciling
Issued 11 April 2017 Resolved
Vessel needs to have three stenciled fire buckets onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 8 May 2017
Resolution: The vessel provided new stenciled fire buckets.