← All vessels
BF GIANT
BF GIANT is a freight ship. The Coast Guard has recorded 8 inspections since 2018, most recently in November 2022, along with 3 deficiencies and 1 operational control.
Records from 2018 to 2022. Most recent: operational control imposed, 7 November 2022.
- Built
- Not recorded
- Last inspected
- 7 November 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9442172 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8UK9
1276632
Flag
LIBERIA
—
Maury page id
psix-1276632
Inspections, by type
…with no type recorded3
Years with a record
3 calendar years (2018–2022)
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it41391 - Convention (Subpart B), Gross Ton
23882 - Convention (Subpart B), Net Ton
23882 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
7 November 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7590380
5 November 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7598496
4 May 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7443822
26 August 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7296897
28 February 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7146336
22 February 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7144543
22 February 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7183084
14 November 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6577662
Deficiency record · 3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2021
Resolved
Means shall be provided whereby normal operations of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. PSC received notification that vessel experience an equipment failure which caused a loss of power while at anchorage.
74 SOLAS(14)II-1/26.3 60 a/c
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 14 November 2018
Resolved
74 SOLAS(14 CONS) XI-1/4/PSC Procedures For Port State Control - Appendix 7: The firefighters took over 5 minuttes to don fire fighting outfits and one firefighter had difficulty operating SCBA. The fire team also did not use proper precautions before entering the space. During the second fire drill the fire team failed to secure after extinguishing the fire.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 November 2018
Resolved
74SOLAS(09CONS) II-2/ 20.3.1.4.1- Arrangements shall be provided to permit a rapid shutdown and effective closure of ventilation. The Number 4 fire damper for the Engine Room did not fully close without forcing it closed.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.