← All vessels
ANDROMEDA
Freight Ship · Bulk Carrier class · Built 2010s · USCG Northeast District (CGD-NE) · Other hulls named ANDROMEDA
ANDROMEDA is a 2013 freight ship. The Coast Guard has recorded 10 inspections since 2015, most recently in August 2026, along with 6 deficiencies — 2 with no resolution recorded — and 1 operational control.
Records from 2015 to 2026. Most recent: inspection, 3 August 2026.
- Built
- 2013
- Last inspected
- 3 August 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9629976 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A3811
1276641
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1276641
Inspections, by type
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19427 - Convention (Subpart B), Net Ton
33729 - Convention (Subpart B), Gross Ton
57825 - Dead Weight, Metric Ton
68672 - Displacement, Metric Ton
33729 - Convention (Subpart B), Gross Ton
57825 - Dead Weight, Metric Ton
68672 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
3 August 2026
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8445665
23 July 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8444872
3 October 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7802917
26 September 2023
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7798601
14 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7197276
1 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7186991
23 April 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7181654
18 March 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7158448
28 December 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5787774
30 November 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5772100
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2026
No resolution recorded
All electrical aparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed spliced, exposed wiring on junction box of Ballast Water Treatment System.
74SOLAS(20)II-1/45.1.3
40a,c
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 August 2026
No resolution recorded
Means shall be provided to control leaks of flammable liquids. PSCO observed oil leaking from heat exchanger on #1 generator.
74SOLAS(20)II-2/4.1.1
40a,c
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 3 October 2023
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel must properly maintain the Ballast Water Management System (BWMS) in accordance with all manufacturer specifications. Vessel's BWMS is not fully operational.
33CFR151.2025(a)(1)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 26 September 2023
Resolved
EACH EMERGENCY GENERATOR SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUPPED WITH STARTING DEVICES APPROVED BY THE ADMINSTRATION WITH A STORED ENERGY CAPABILITY OF AT LEAST THREE CONSECUTIVE STARTS. PSCO OBSERVED THE EMERGENCY GENERATOR WOULD NOT START ON BATTERY POWER.
74 SOLAS 20 11-1/44.2
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 30 November 2015
Resolved
0715; The function of the fixed fire detection and alarm systems shall be periodically tested to the satisfaction of the Administration. Vessel does not have appropriate means of testing the flame detection system, 74 SOLAS (09)II-2/7.3.2, 40c.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 30 November 2015
Resolved
2510; Vessel must maintain a BWM & Bio-fouling Plan that has been developed specifically for the vessel that will allow those responsible for the plans to understand and follow them. Vessel is not following BWM plan, whereas forms are being filled out incorrectly; also, vessel has no Bio-fouling Management Plan onboard, 33 CFR 151.2050(g, MEPC 207(62, 10c.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.