CARNIVAL VISTA

CARNIVAL VISTA is a 2015 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 2016, most recently in May 2026, along with 26 deficiencies and 9 operational controls.

Records from 2016 to 2026. Most recent: inspection, 24 May 2026.

Built
2015
Last inspected
24 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9692569
1276735
Flag
PANAMA
Maury page id
psix-1276735

Documentation record

Tonnage as PSIX records it133596 - Convention (Subpart B), Gross Ton
12293 - Dead Weight, Ton
69481 - Displacement, Ton
122733 - Regulatory (Subpart C or D), Net Ton
133596 - Regulatory (Subpart C or D), Gross Ton
122733 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 46

24 May 2026 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8376973
28 November 2025 COC-CVE Quarterly · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8274835
20 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8271442
20 September 2025 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8264840
31 May 2025 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8148658
30 November 2024 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8039476
13 October 2024 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8018375
15 September 2024 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7984252
29 August 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7991940
10 August 2024 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7978220
1 June 2024 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7923088
23 December 2023 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7841993
4 December 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833335
1 December 2023 PSC B · COC-CVE Quarterly · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7832583
3 June 2023 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7697095
3 December 2022 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7602624
18 June 2022 PSC B · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7476430
31 January 2022 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7390238
11 December 2021 COC-CVE Quarterly
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7366287
24 June 2021 ISPS Exam · COC-CVE Annual · PSC C · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7233521
28 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944984
22 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6942574
4 April 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6935464
28 December 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6880231
9 November 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6854729
26 October 2019 Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6837220
13 April 2019 ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6636781
3 March 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6662541
11 January 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6609461
28 October 2018 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6549873
28 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6525611
13 May 2018 Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6411091
7 April 2018 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6404482
24 February 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6378863
29 October 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6293963
18 July 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6213139
3 June 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6168196
30 April 2017 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6132008
21 February 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6092006
28 January 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6081037
26 January 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6077545
3 November 2016 ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6033973
21 October 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6026934
9 April 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5850372
3 February 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5808568
6 January 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5809384

Deficiency record · 26

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 May 2026 Resolved
07114 Oil fuel pipes, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position. Quick closing valve NP-469VD (purifier suction) was tested and did not close. 74 SOLAS (20) II-2/4.2.2.3.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2026
Resolved 24 May 2026
Resolution: The quick closing valve was repaired returning it to proper operation and normal function.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 May 2026 Resolved
07120 The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the following functional requirements shall be met: .1 safe escape routes shall be provided; Room in a room smoke alarm detector # DET 307-024 did not activate audibly when tested. 74 SOLAS (20) II-2/13.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2026
Resolved 24 May 2026
Resolution: The audible portion of the smoke alarm detector was repaired and tested showing full functionality.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 24 May 2026 Resolved
04110 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The assistant lifeboat coxswain on Lifeboat #21 was not familiar with firefighting appliances and the procedure for extinguishing a fire in the engine compartment. 74 SOLAS (20) III/19.2.1 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 May 2026
Resolved 24 May 2026
Resolution: The crewmember was replaced with a new assistant coxswain showing competency in the required emergency duties.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 May 2025 Resolved
07105 The construction of door and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the door are situated. Doors leading from the galley of the blue iguana and burger joint (both category 12) were found to have a B-15 door leading to the open pool deck area (category 5 space). The fire control plan states ther boundary between the category 12 (galley) and category 5 (pool deck) is an "A" class boundary. 74 SOLAS 20 II-2/9.4.1.1.2 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 8 June 2025
Resolution: Class submitted report stating that class B doors are allowed in the space as it is the last MVZ and door does not lead to lifesaving appliances and not part of the superstructure.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 May 2025 Resolved
07115 Where it is necessary that a ventilation duct passes the operating position shall be readily accesible and be marked in a red light-reflecting colour. PSCO observed the fire dampers C205 (ECR Panel) and incinerator room indicating light extinguished. 74 SOLAS 20 II-2/9.4.1.1.9 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 8 June 2025
Resolution: Extinguished indicating lights of Fire Dampers control panels now verified working and indicating properly. - LR
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 May 2025 Resolved
Escape routes shall be provided with clear markings for emergency situations. PSCO observed no emergency exit signage leading to escape routes in the port azipod control room. 74 SOLAS 20 II-2/13.1.3 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2025
Resolved 8 June 2025
Resolution: Azipod rooms emergency exit signage of the escape routes now satisfactorily verified installed. -LR
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 May 2025 Resolved
07105 Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5* opposing closure. FSD's 0.3.28, 0.4.17, and 0.5.20 would not release from their magnets upon activation, preventing the from closing. FSD 6.1.04 would not fully close upon testing. 74 SOLAS 20 II-2/9.4.1.1.5.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2025
Resolved 31 May 2025
Resolution: Doors were repaired to their original installation and shown to function and close correctly.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 31 May 2025 Resolved
07123 Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. A rag was found wrapped around a high pressure water mist nozzle in the Print Shop on Deck 4, completely covering the nozzle discharge. 74 SOLAS 20 II-2/14.2.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2025
Resolved 31 May 2025
Resolution: The rag was removed restoring the nozzle ability to discharge.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 May 2025 Resolved
The means of escape shall be marked by lighting or photoluminescent strip indicators. PSCO observed extinguished low-location lighting in the forward stairway deck 14. 74 SOLAS 20 II-2/13.3.2.4.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2025
Resolved 31 May 2025
Resolution: Reapirs were made to the lighting
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2025 Resolved
07199 Category 10 spaces are those where combustible materials can be used for storage. There was a substantial amount of cardboard boxes found within A/C room. 74 SOLAS 20 II-2/9.2.2.3.2.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 May 2025
Resolved 31 May 2025
Resolution: Cardboard was removed from the space.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 31 May 2025 Resolved
11131 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The second coxswain on LB# 19 could not explain the operation or prpose of the release gear nor shut off the engine. LB# 20's coxswain and second coxswain could not describe procedures to fight a fire in the engine nor location or operation of the bilge pump. LB#15's second coxswain could not describe or preform a shutting off of the LB's engines. 74 SOLAS 20 III/19.2.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2025
Resolved 31 May 2025
Resolution: Crew members were reassessed by USCG and found to have sufficient knowledge.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 August 2024 Resolved
02105 - The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. On August 10th Vessel reported while underway and arriving to Port Canaveral, FL the vessels Starboard Azipod was experiencing high temperatures in the rotor casing of the Azipod. The temperature rosed from 75 degrees Celcius to 143 degrees Celcius in approximately 10 minutes. The vessels crew could not identify the root cause of the increase of temperature. 74 SOLAS (20) I/11, Code 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 August 2024
Resolved 15 September 2024
Resolution: LR rep was on board and found the vessel in compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 December 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The crew for Lifeboat #14 could not demonstrate knowledge of lifeboat lowering. 74 SOLAS 20 III/19.2.1 11113
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2023
Resolved 2 December 2023
Resolution: Vessel was able to replace the LB crew with adequately trained members.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 December 2023 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photolumlnescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Low location lighting on the forward stairway on deck 12 to 14 by the spa were found to be inoperable. Additionally, escape route in the arcade room was not clearly marked. 74 SOLAS 20 II-2/13.3.2.5.1 07120
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2023
Resolved 13 December 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 December 2023 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire fighting system and appliances they may be called on to use. Multiple crew members (10) could not demonstrate proficiency in basic fire fighting knowledge, to include loaction of manual call points, operations of drencher system, and location/operation of fire extinguishers. 74 SOLAS 20 II-2/15.2.2.1 04109
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2023
Resolved 16 December 2023
Resolution: An inspection team attended the vessel and requestioned random fire fighting teams.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 December 2023 Resolved
Companies, masters and crew members each have a responsibility to ensure that each crew member can make a knowledgeable and informed contribution to the safe operation of the ship. 04 crewmembers failed to articulate the requirement to call 911 in the event of a medical emergency, contradicting the vessels on board safety instructions. STCW 2017 A-1/14.1 04117
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2023
Resolved 16 December 2023
Resolution: Inspection team attended the vessel and questioned random crew members. Additionally, verified additional training for the crew members.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 2 December 2023 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Markings were not painted and did not contrast against the hull of the ship. ILLC(88)8 01108
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 December 2023
Resolved 13 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 December 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. 02 fire doors on 1-95 were blocked by luggage that was not being actively attended by crewmembers. As a result, the fire doors were rendered incapable of closing. 74 SOLAS 20 II-2/9.4.1.1.5.1 07105
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 December 2023
Resolved 2 December 2023
Resolution: Luggage was moved out of the space.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 2 December 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairway guide on deck 09 could not demonstrate proper procedures for notification of emergencies. 74 SOLAS 20 111/19.2.1 11131
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 December 2023
Resolved 2 December 2023
Resolution: Crew members were properly trained and retested after training by PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. PSCO observed double-leaf fire door 2.5.05 did not latch when closed. 74 SOLAS 20 II-2/9.4.1.1.5.12
Action required: 10 - Deficiency Rectified
Resolved 3 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 June 2022 Resolved
ABOVE THE BULKHEAD DECK, THERE SHALL BE ATLEAST TWO MEANS OF ESCAPE FROM EACH MAIN VERTICAL ZONE OR SIMILARLY RESTRICTED SPACE OR GROUP OF SPACES, AT LEAST ONE OF WHICH SHALL GIVE ACCESS TO A STAIRWAY FORMING A VERTICLE ESCAPE. PSCO OBSERVED DOUBLE-LEAF FIRE DOORS LEADING TO THE AFT STAIRCASE ON THE 02 DECK WAS STUCK SHUT AND WOULD NOT OPEN WITH FORCE APPLIED TO EITHER SIDE. 74SOLAS 20 II-2/13.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 June 2022
Resolved 18 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2022 Resolved
IT SHALL BE POSSIBLE FOR EACH DOOR TO BE OPENED AND CLOSED FROM EACH SIDE OF THE BULKHEAD BY ONE PERSONONLY. PSCO OBSERVED MAGNETIC DOOR RELEASE FOR FIRE DOORS 1.1.02 DID NOT FUNCTION WHEN PUSH BUTTON RELEASE WAS ACTIVATED. FIRE DOORS 3.2.13 WOULD NOT LATCH WHEN ACVIVATED TO CLOSE 74 SOLAS 20 II-2/9.4.1.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 June 2022
Resolved 18 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 June 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSC Examiners during life boat operational testing discovered #15 life boat could not engage the starboard engine.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2021
Resolution: Vessel crew repaired linkage and demonstarted satisfactory operation.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Approved method
Issued 28 April 2020 Resolved
While operating within an emission control area, the sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% m/m on and after 1 January 2015. Vessel burned non-compliant heavy fuel oil without using exhaust gas cleaning system in the North American ECA on 21 April 2020. Marpol VI/14.4.3 10c
Action required: 10 - Deficiency Rectified
Due 28 April 2020
Resolved 28 April 2020
Lifesaving › Immersion Suits › Not on Board
Issued 29 October 2017 Resolved
74SOLAS (2014) III/7.3 - An immersion suit or anti-exposure suit of an appropriate size, shall be provided for every person assigned to the marine evacuation system party. Immersion suits were not available to marine evacuation system team members.
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 10 November 2017
Resolution: Flag Exemption issued to the vessel while operating between 32 degrees N and 32 degrees S latitude.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 July 2017 Resolved
Vessel did not meet ANOA requirements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 July 2017
Resolution: Vessel opted to pay a civil penalty in order to arrive per their schedule.