MAURY USCG vessel records
← All vessels

OVATION OF THE SEAS

OVATION OF THE SEAS is a passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2016, most recently in July 2026, along with 11 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 12 July 2026.

Built
Not recorded
Last inspected
12 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9697753
1276736
Flag
BAHAMAS, THE
Maury page id
psix-1276736

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it11113 - Dead Weight, Ton
78130 - Displacement, Ton
168666 - Convention (Subpart B), Gross Ton
154078 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 49

12 July 2026 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8436277
26 January 2026 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8301920
31 May 2025 COC-CVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8147127
17 September 2024 Security Breach, Potential
Type not classified · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8005676
13 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7929770
29 April 2024 PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7901639
3 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7906183
12 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7889991
9 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7870641
12 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842537
26 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7802263
12 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763319
22 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745266
15 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7735033
2 May 2023 COC-CVE Annual · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679215
28 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643533
4 January 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616432
30 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7602095
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7577044
24 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542744
9 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529396
29 July 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519801
23 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7485467
15 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478433
14 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7477785
18 April 2022 COC-CVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7424563
5 October 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7327880
28 July 2021 MARPOL Annex I Examination · ISPS Exam · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7235044
10 April 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6938091
25 February 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6915303
29 January 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6898713
16 January 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6891089
26 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6863087
13 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6855089
30 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6824769
30 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6824965
29 September 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6907330
25 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821057
6 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6805718
30 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799185
5 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6773646
26 July 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6761715
20 July 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6756095
27 May 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6704125
16 May 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6688855
24 April 2019 ISPS II Exam · COC-CVE Initial · PII Safety Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668981
13 September 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6286730
29 March 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5842506
18 February 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5817224

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 May 2025 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed fire door (FD-01-2-010) leading to laundry room did not properly close due to storage in closing range of fire door. 74 SOLAS 20 II-2/9.4.1.1.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 31 May 2025
Resolution: Vessel removed storage in way of closing fire door. Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. FD-02-5-001 did not close completely. 74 SOLAS 20 II-2/9.4.1.1.5.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Door was observed to close after crewmembers were sent to fix FD-02-5-001.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 April 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Auxiliary machinery spaces which do not contain machinery having a pressure lubrication system and where storage of combustibles is prohibited, such as: ventilation and air-conditioning rooms; A/C room behind FD-06-3-004 had cardboard boxes being stored in the space. 74 SOLAS 20 II-2/9.2.2.3.2.2.10
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: A/C room behind FD-06-3-004 was cleared to be in compliance with regulation and is no longer being used as storage space.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 May 2023 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Identified combustible materials inside AC Room, within FD-06-3-004. 74 SOLAS 20 II-2/9.2.2.3.1 Code 07101 Action 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Combustible materials were removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2023 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. The following fire screen doors did not operate as designed: FD-02-7-002, FD-04-5-017, and FD-06-4-004. 74 SOLAS 20 II-2/9.4.1.1.1 Code 07105 Action 07105
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 May 2023
Resolution: Fire screen doors were repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 July 2021 Resolved
Operational readiness. Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. The sprinkler head in the perfume shop on deck 4 zone 3 appeared damaged and was dripping water. SOLAS 20 II-2/2 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 29 July 2021
Resolution: Vsl provided picture showing fixed sprinkler head
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 July 2021 Resolved
Openings in bulkheads and decks in passenger ships. Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be capable of remote release individually from a position at both sides of the door. Fire screen door 02-5-009 did not close from local releases. SOLAS 20 II-2 9.4.4.1.1.4.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 29 July 2021
Resolution: vsl provided video of fire screen door closing from both sides, after local activation.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 28 July 2021 Resolved
Detection and alarm. A fixed fire detection and alarm system for passenger ships shall be capable of remotely and individually identifying each detector and manual call point. The manual call point located on deck 5 forward of "Jamie's Italian" immediately next to call point 5-64-082 is not labeled.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 29 July 2021
Resolution: vsl provided photo of call point with new ID number attached
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 September 2019 Resolved
All lifeboats shall have rigid hulls and shall be capable of maintaining positive stability when in an upright position in calm water and loaded with their full complement of persons and equipment. Gel coating on lifeboat # 4 was damaged, revealing fiberglass cloth on the starboard quarter. Damage reported by vessel prior to exam.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2019
Resolved 30 September 2019
Resolution: Recieved class survey report attesting to servicability of lifeboat
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 May 2019 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Double leaf fire door 05-6-009 and sliding fire door 04-6-002 did not close upon remote activation from the navigation bridge.
Action required: 10 - Deficiency Rectified
Resolved 3 May 2019
Resolution: Doors were successfully tested prior to completion of exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 May 2019 Resolved
For a period of 36h, emergency lighting in alleyways, stairways, and exits giving access to the muster and embarkation stations as required by regulation III/11.5. Emergency lights in vicinity of outdoor pool towel stations on Deck 14 port and starboard side did not energize during transitional power test.
Action required: 10 - Deficiency Rectified
Resolved 3 May 2019
Resolution: Light bulbs were replaced and tested operational prior to concluding exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.