KONINGSDAM

KONINGSDAM is a 2016 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 2016, most recently in March 2026, along with 40 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 10 March 2026.

Built
2016
Last inspected
10 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9692557
1276737
Flag
NETHERLANDS
Maury page id
psix-1276737

Documentation record

Tonnage as PSIX records it9428 - Dead Weight, Metric Ton
99836 - Convention (Subpart B), Gross Ton
68234 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 53

10 March 2026 PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8323395
15 September 2025 COC-CVE Annual · Ballast Water Examination · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8233425
23 February 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8082670
9 September 2024 Deficiency Check · COC-CVE Annual · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7999553
7 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7930114
5 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7906172
30 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7905469
23 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7895592
27 February 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7870660
17 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7872330
30 January 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7871921
6 January 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7875844
5 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842567
3 November 2023 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7819858
2 October 2023 COC-CVE Annual · Deficiency Check · Ballast Water Examination · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7801856
11 July 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7813057
20 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763656
6 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7762580
23 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7749446
9 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7734355
8 May 2023 Deficiency Check · COC-CVE Quarterly · PSC B · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7683307
20 April 2023 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7672519
28 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643508
4 January 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616389
21 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7598183
16 November 2022 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7595831
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576765
3 October 2022 Ballast Water Examination · PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7570926
24 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542533
9 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529168
9 August 2022 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529453
23 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7485455
21 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483408
13 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476806
6 May 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7445062
18 April 2022 COC-CVE Quarterly · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7431295
9 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7408932
28 February 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7403385
28 February 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7403391
26 February 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7434152
3 November 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345331
4 October 2021 Ballast Water Examination · COC-CVE Annual · PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7321588
20 June 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7230535
6 December 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6868519
13 November 2019 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6853678
11 November 2018 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6577159
15 March 2018 ISPS III Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6368973
29 November 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6314827
18 October 2017 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6289941
23 November 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6046703
9 November 2016 ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038447
3 February 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5808567
6 January 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5781114

Deficiency record · 40

14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 15 September 2025 Resolved
Every ship of 12 m or more in length overall and fixed or floating platforms shall display placards which notify the crew and passengers of the discharge requirements of regulation 3,4,5 and 6 of this annex. Resolution MEPC 219(63) requires where ships carries passengers, placards also should be placed in prominent places where passengers are accommodate and congregated. These include cabins, all deck areas for recreational purposes open to passengers. MARPOL placard were not found on any open deck open to passengers including deck 5 crew observation area sometimes utilized by passengers. MARPOL 2017 Annex V/10.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in safe conditions, clear of obstacles. Exterior escape doors leading to the weather decks on deck 5 and 4 were seized shut and required extreme force to open. 74SOLAS 20 II-2/13.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more then 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additional, escape route signs and fire equipment location marking shall be of photoluminescent material or marked by lighting. Aft crew elevator leading on deck 6 through 4 is blocked by trolly storage. 74SOLAS 20 II-2/13.1.2
Action required: 15 - Rectify deficiencies by next port
Resolved 20 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, remote release sliding or power operated doors shall be equipped with an alarm that sounds at least 5 s but no more than 10 s after the door is released from the central control station and before the door begins to move and continues sounding until the door is completely closed. Fire door 6417 failed to close within 10 seconds. 74SOLAS 20 II-2/9.4.1.1.5.10
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 September 2025 Resolved
The load line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. The deck line associated with the load line is painted the same blue blue color as the hull. ILLC 8
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2025 Resolved
In multi engine installations which are supplied from the same fuel source , means of isolating the fuel supply and spill piping to individual engines shall be provided. #1 and #3 generator fuel supply quick closing valves did not close upon first activation attempt. 74SOLAS 20 II-2/4.2.2.5.2
Action required: 10 - Deficiency Rectified
Resolved 20 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 September 2025 Resolved
Fire hoses shall be of non-perishable material and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and necessary couplings. Hoses specified in this chapter as fire hoses shall, together with any necessary fittings and tools, be kept ready for use... 03 fire hoses (ivo FE 0D.05.07, Hose: 0C.02.24 & 0C.01.35) spanner wrench were missing at the fire hose station. 74SOLAS 20 II-2/10.2.3.1.1
Action required: 10 - Deficiency Rectified
Resolved 20 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 September 2025 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire hose station (ivo Cabin A002) required a cross key for access, making it not available for immediate use. 74SOLAS20 II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 20 September 2025
Resolution: Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2025 Resolved
Containers, brackets, rack, and other similar stowage locations for life saving equipment shall be marked with symbols in accordance with the recommendations of the organization, including the devices stowed in that location for that purpose. The lifebuoy located stbd side bow has wrong placard. The lifebuoy indicates it should have an attached line but, the LSA plan shows a lifebuoy with no line. 74SOLAS20 III/20.10
Action required: 10 - Deficiency Rectified
Resolved 20 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2025 Resolved
Waste receptacles shall be constructed of non combustible materials with no openings in the side or bottom. Combustible waste receptacles were found for the collection of plastic and other combustible waste at the recycling center on deck 1. 74SOLAS20 II-2/4.4.2
Action required: 10 - Deficiency Rectified
Resolved 20 September 2025
Resolution: Rectified
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 16 September 2024 Resolved
An International Oil Pollution Prevention Certificate shall be issued, after an initial or renewal survey to any ships of 400 gross tonnage and above which are engaged in voyages to ports or offshore terminals under the jurisdiction of other parties to the present convention. PSCO observed the throughput of the OWS missing on the IOPP. MARPOL 2017 Annex I/7.1 16ac
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2024
Resolved 17 September 2024
Resolution: Class society reissued correct certificate
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 September 2024 Resolved
Fire-fighting equipment and appliances shall be kept in good working order and readily available for immediate use. PSCO observed suspected dry rot of CO2 hoses in main CO2 room. 74 SOLAS 20 II-2/14.2.1.2 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2024
Resolved 20 September 2024
Resolution: Evidence received of old hoses replaced with new hoses.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 16 September 2024 Resolved
The company shall ensure that; valid documents are available at relevant locations. PSCO observed IOPP issued in 2021, endorsed in 2022 and 2023 and did not have a listed throughput of their OWS. As seen in subsequent deficiency of IOPP issued by class. External audit required. 74 SOLAS 20 IX ISM code A.11.2.1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 18 November 2024
Resolution: External audit conducted 29/30th October.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2024 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed non-combustible container in collection area for combustible materials outside of the garbage room. 74 SOLAS 20 II-2/4.4.2 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 16 September 2024
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 September 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, release mechanism shall be so designed that the door will automatically close in the event of disruption of the control system or central power supply. The following fire doors would not shut when released: 9.5.04, 9.5.22, D.2.14, A.3.78, 1.5.27, 4.3.43
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 September 2024
Resolution: Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 October 2023 Resolved
All life-saving applicnes and arrangement shall comply with the applicable requierments of the code. The engine system and starting aids shall start the engine...within 2 minutes of commencing the start procedure. Upon testing, lifeboat #4 did not start. 74SOLAS(20) III/34 LSA Code 4.4.6.2 Action code: 17ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2023
Resolution: Received class report attesting to lifeboat operation.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 2 October 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Multiple stariway guides on various decks in the forward stariway were unable to provide the correct passanger muster station utilizing the passanger cabin referece card located on the starway guide's lifejacket. 74SOLAS(20) III/19.2.1 Action Code: 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2023
Resolution: Vessel provided proof of training to PSCOs during def check on 03OCT
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 October 2023 Resolved
Waste recepticles shall be constructed of non-combustable materials with no openings in the side or bottom. PSCO observed plastic garbage cans in the crew office, entertainment office, and in various galleys on deck 1, 2, and 3. 74SOLAS(20) II-2/4.4.2 Action Code: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2023
Resolution: Received class report attesting to plastic garbage cans being removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2023 Resolved
Below the bulkhead deck, two means of escape, at elast on of which shall be independent of watertight doors, shall be provided from each watertight compartment or similar restricted space or group of spaces. PSCO observed a space in the linen store/tailor shop on C-deck forward, fire zone 6, that appeared modified. The space did not provide tow means of escae and the escape routes provided did not match the apprved evacuation plan. 74SOLAS(20) II-2/13.3.2.1.1 Action Code: 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2023
Resolution: Class fact statement report provided. Longitudinal wire fence obstruction that fitted between frames 318-321 stbd, now removed
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2023 Resolved
The means of escape, including stairway and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route , including angles of intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. The door directly outside the Stuyvesant meeting room, in indicated as a means of escape to the muster station with IMO symbols but does not have escape route signage. 74SOLAS(20) II-2/13.3.2.5.1 Action Code: 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2023
Resolution: Appropriate escape route signage was installed at door.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2023 Resolved
The following functional requierments shall be met: escape routes shall be maintained in safe conditions, clear of obstables. Carts and trash cans were observed IVO the strway outside of the garbage sorting room on deck 1, impeeding the means of escape. 74SOLAS(20) II-2/13.1.2 Action Code: 10c
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: Carts and trash cans were relocated, allowing for an unobstructed means of escape
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 October 2023 Resolved
Doors and door frames in "B" class division and means of securing them shall propvide a method of closure whcih shall have resistance to fire equivelent to that of the disvision. B-15 door IVO FSD 2.3.90 does not latch. 74SOLAS(20) II-2/9.4.1.2.1 Action Code: 10c
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: Latch system was installed, allowing the door to be placed in a latched position.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 8 May 2023 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Eight embarkation lights on the starboard side and one on the port side, aft were extinguished. 74 SOLAS 20 III/11.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2023
Resolution: Photos sent of illuminated embarkation lights.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2023 Resolved
The means of escape, including staiways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. In the ship's medical center, various furniture items including couches/chairs/filing cabinet were obstructing low location lighting. 74 SOLAS 20 II-2/13.3.2.5.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2023
Resolution: Low location lighting no longer obstructed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 May 2023 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. Deck 4, aft, crew elevator shaft was obstructed by several steward carts, allowing for less than 800mm of escape. Additionally, A deck stairwell adjacent to electricians office had a utility cart blocking means of escape. 74 SOLAS 20 II-2/13.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2023
Resolution: Utility cart and steward carts relocated. Escape no longer obstructed.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 May 2023 Resolved
Prior to being assigned shipboard duties on board passenger ships, seafarers shall have completed the training required by paragraphs 4 to 7 below IAW their capacity, duties and responsibilities. During abandon ship drill, PSCO observed several stairwell guides throughout all three stairtowers who were unfamiliar with the procedures for allowing passengers to return to their staterooms during the general emergency alarm signal. STCW V/2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2023
Resolution: Class report submitted. Training conducted May 9th.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2023 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and pentrations in these divisions. A-60 insulation was missing in the aft auxiliary machinery space IVO WTD C.7. 74 SOLAS 20 II-2/13.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 8 May 2023
Resolution: Insulation replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2023 Resolved
The capacity of the generating sets shall be such that in the event of any one generating set being stopped it will still be possible to supply those services necessary to provide normal operational conditions of propulsion and safety. Upon manual shut down of DG#1, DG#3 became overloaded and shut down causing a temporary black out and loss of propulsion. 74 SOLAS (20) II-1/41.1.2
Action required: 15 - Rectify deficiencies by next port
Due 20 April 2023
Resolved 21 April 2023
Resolution: Sector Honolulu received class report stating fuel injector for DG #1 was repaired.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2022 Resolved
Means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators. PSCO observed security screening equipment was blocking photo luminescent strips in A deck forward crew corridor in vicinity of fire screen door A.5.17. SOLAS 20 II-2/13.3.2.5.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2022
Resolution: Received Factual Statement from class society stating deficiency has been cleared.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2021 Resolved
Ensure slot machines located in front of embarkation windows meet the requirements of 5 liters per minute application rate for A-60 boundary adjacent to STBD embarkation station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 9 November 2021
Resolution: Class cleared def. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 4 October 2021 Resolved
All lifeboats shall be fitted with sufficient watertight lockers for the storage of small items of equipment, water, and provisions. Every lifeboat foudn with plastic totes of P.P.E in way of seating arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2021
Resolved 9 November 2021
Resolution: Class cleared def. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2019 Resolved
Fire doors... shall satisfy the following requirements... double-leafed doors equipped with a latch necessary for their fire integrity shall have a latch t hat is automatically activated by the operation of the doors when released by the system. PSCOs noted 8 fire doors that were unoperable due to the sequencing bars not being adjusted properly. Fire doors: A.3.43, A.3.45, A.3.70, A.4.48, 5.2.47, 10.2.35, 9.4.34. 74 SOLAS 14 II-2/9.4.1.1.5.12
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 6 December 2019
Resolution: Crew adjusted the nut that controls the sequencing bar adjustment. All the double doors with sequencing bars were checked by crew. Class report sent in.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 November 2019 Resolved
Above the bulkhead deck there should be at least two means of escape from each main vertical zone. A/C room spanning from decks 4, 5, and 6 is missing secondary means of escape on deck 4. Fire control plan lists emergency escape through a ladder connecting all three decks, however this ladder does not lead to deck 4 as indicated by the plan. 74 SOLAS 14 II-2/13.2.2
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2019
Resolved 6 December 2019
Resolution: Ladder installed in the A/C room to ensure two means of escape from all decks in the space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 November 2018 Resolved
1430- Main and Auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. RPM table not present in emergency steering gear compartments. Emergency Propulsion Station. 74SOLAS (14) II-1/31.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2018
Resolved 22 November 2018
Resolution: Vessel sent in pictures of added RPM table
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 November 2018 Resolved
0750- Doors and door frames in "B" Class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. Several "B" Class doors on Deck 9 galley were wedged open, compromising B class boundary. 74SOLAS (14) II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 November 2018
Resolved 11 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 November 2018 Resolved
2025- Each Abandon ship drill shall include a mock search and rescue of passengers trapped in their state rooms. Crew members responsible for clearing rooms on deck 4 port side forward did not properly carry out their duties to ensure that the rooms were cleared 74SOLAS (14) III/19.3.3.1.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 November 2018
Resolved 11 November 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 March 2018 Resolved
0680-PSCO observed 04 embarkation lights were not working properly on the ships port side. 74SOLAS 14 iii/11.4
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 15 March 2018
Resolution: Deficiency was corrected and cleared by PSCO while still onboard.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 29 November 2017 Resolved
1410- The condition of the ship and its equipment shall be maintined to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel reported intermittent loss of RPM control on both port and starboard azipods and are receiving an RPM alarm when operating in bridge control. -74SOLAS(14) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2017
Resolved 29 November 2017
Resolution: ABB Technician reported the issue was caused by defective network switches and bent fiberoptics. These components were repaired and replaced. Tested bridge RPM and pod angle capability to satisfatcion of Class and Coast Guard.
Lifesaving › Launching Appliances › Falls
Issued 18 October 2017 Resolved
74SOLAS(2014) Ch. III/20.4 - Falls used in the launching shall be inspected periodically with special regard for areas passing through sheaves, and renewed when necessary due to deterioration of the falls or at intervals of not more than 5 years, whichever is the earlier. Vessel discovered deterioration of falls on all 6 tender boats.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2017
Resolution: All 6 tender vessel wire cables were replaced and tested satisfactorily.
Fire Fighting › Means of Escape › Blocked
Issued 9 November 2016 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Combustible & misc items were stowed in multiple stairwells. - 74Solas(09) CH. II-2/13.1.2
Due 9 November 2016
Resolved 9 November 2016
Resolution: Items removed prior to completion of exam. Cleared while onboard.