← All vessels
CLIPPER BELLE
CLIPPER BELLE is a 2014 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in August 2024, along with 4 deficiencies and 1 operational control, 1 with no removal date recorded.
Records from 2016 to 2024. Most recent: inspection, 19 August 2024.
- Built
- 2014
- Last inspected
- 19 August 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9675781 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRSD2
1276965
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1276965
Inspections, by type
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it61411 - Dead Weight, Metric Ton
72322 - Displacement, Metric Ton
34803 - Convention (Subpart B), Gross Ton
20222 - Convention (Subpart B), Net Ton
72322 - Displacement, Metric Ton
34803 - Convention (Subpart B), Gross Ton
20222 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
19 August 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7981992
18 July 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7260460
6 July 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7246469
19 January 2021
ISM Exam · Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7123371
23 July 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6475693
20 May 2018
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6398426
25 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149994
23 March 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838697
Deficiency record · 4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 19 January 2021
Resolved
Objective evidence discovered during the expanded ISM Exam revealed the following non-conformities. The comoany failed to full implement the requirements of the ISM Code through their Safety Management System procedures as evident by the following deficiencies indicating that the vessel and or Company are not meeting the Safety Management System requirements. Internal audit required within 3 months.
-74SOLAS(14)IX/3.1 ISM Code Part A
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 January 2021
Resolved
Precautions shall be taken to prevent any oil that may escape under pressure from pump from coming into contact with heated surfaces. PSCO observed active leaks on the #1 and #2 fuel oil circulating pumps and booster pumps.
-74SOLAS(14)II-2/4.2.2.6.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 19 January 2021
Resolved
Surfaces with temperatures above 220 degrees C which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO observed oil soaked lagging on the #1 and #2 fuel oil circulating pumps and booster pumps.
-74SOLAS(14)II-2/4.2.2.6.1
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 March 2016
Resolved
2050-Op of Mach-Each emergency gen. set arranged to be auto started shall be equipped with starting devices approved by the Admin. with a stored energy capability of at least 3 consecutive starts. A second source of energy shall be provided for an add. 3 starts within 30 min unless manual starting can be demonstrated to be effective. Emergency generator starting arrangements cannot (see narrative)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.