MAURY USCG vessel records
← All vessels

ONE HAMMERSMITH

ONE HAMMERSMITH is a 2009 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in May 2026, along with 5 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 28 May 2026.

Built
2009
Last inspected
28 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9395147
1277080
Flag
PANAMA
Maury page id
psix-1277080

Documentation record

Tonnage as PSIX records it98849 - Dead Weight, Metric Ton
134854 - Displacement, Metric Ton
98747 - Convention (Subpart B), Gross Ton
35315 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

28 May 2026 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8381763
18 September 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8236764
15 August 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7768737
17 November 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352820
22 July 2021 PSC B · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7263842
13 December 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874771
12 December 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6872558
3 September 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6802886
13 August 2018 Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6510461
6 July 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6199511
22 May 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6152737

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 May 2026 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed leakage from the strainer on the purifer causing oil accumulation of 03-04 inches of oil in the containment and bilge.74SOLAS(24)II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2026
Resolved 28 May 2026
Resolution: Vessel provided class report; cleared at 1938 on 28 May 2026. See attached in documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 May 2026 Resolved
The Machinery,Boilers and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed oil soaked lagging on HFO settling tank steam pipe and over flow drainage pipes
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2026
Resolved 28 May 2026
Resolution: Vessel provided class report; cleared at 1938 on 28 May 2026. See attached in documents.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 July 2021 Resolved
Fixed fire detection and fire alarm system installation shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. PSCO observed the testing of 02 smoke alarms in the engine room and neither activated. Cite:74SOLAS(20) 11-2/ 7.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: Remote Class Survey was provided attesting to the condition of the smoke alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 22 July 2021 Resolved
An immersion suit shall be constructed with waterproof materials such that it can be unpacked and donned without assistance within 2 minutes; taking into account donning of any associated clothing, donning of a lifejacket if the immersion suit is to be worn in conjunction with a lifejacket. PSCO observed crewmembers unable to don immersion suits within 2 minutes. Cite:74 SOLAS (20) III/7.3 LSA 2.3.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2021
Resolution: PSCO observed 03 crew members successfully donned their immersion suits within 2 minutes.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 August 2018 Resolved
SOLAS(14) I/11THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITH OUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED MULTIPLE SOFT PATCHES ON THE VESSELS MARINE SANITAION DEVICE THAT WERE NOT APPROVED BY CLASS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 August 2018
Resolution: Received satisfactory class report attesting to the soft patch on the MSD and allowing it to go until next DD on 22FEB19.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.