CARIBOU is a 2015 offshore supply vessel. The Coast Guard has recorded 17 inspections since 2016, most recently in September 2025, along with 9 deficiencies and 1 casualty investigation in 2025.
Records from 2016 to 2025. Most recent: inspection, 5 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1170 - Convention (Subpart B), Gross Ton 99 - Regulatory (Subpart C or D), Gross Ton 351 - Convention (Subpart B), Net Ton 67 - Regulatory (Subpart C or D), Net Ton 1610 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
5 September 2025Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8218909
26 August 2025Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8218217
10 May 2025Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8132194
10 May 2025Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8132231
28 August 2024Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7990889
12 June 2024Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7933796
20 July 2023Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7747831
31 May 2023COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7688556
25 August 2022Cargo Tank Internal · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7546968
25 January 2022Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7385412
13 January 2020Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6888540
26 July 2019In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6762734
18 June 2019In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6720517
2 November 2018Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573111
Nothing in this part shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. MI was notified that the vessel allided with a rig and caused damages to the vessels port quarter to include a inset and puncture of the vessels generator day fuel tank. Vessel is transiting to homeport of Adriatic Marine LLC. pier in Port Fourschon.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2025
Resolution: Repairs complete - witnessed dye pen and ABS witnessed pressure test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 June 2024Resolved
Electrical equipment on a vessel must be designed, installed and maintained to provide services necessary for safety under normal and emergency conditions.
Vessel suffered a class c fire on the #2 SSDG panel while underway. Vessel will moor in Port Fourchon, LA to investigate and conduct repairs prior to departure to USCG satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2024
Resolved 18 June 2024
Resolution: Generator repaired as well as panel. Held load with no issues. Sat.
Transfer procedures are required to comply with 33 CFR 155.750. Proceedures onboard do not include any part of the flowback operations including a line diagram. Provide transfer procedures flowback operations to include a line diagram.
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 26 July 2019
Resolved 26 July 2019
Resolution: Transfer procedures provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2018Resolved
Packing glad on shaft was leaking water into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2018
Resolved 12 December 2018
Resolution: ABS conducted sea trials following the USCG inspection, confirmed deficiency was rectified prior to heading to sea.
Watertight doors and hatches in the engine room require adjusting to make proper watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2018
Resolved 12 December 2018
Resolution: ABS conducted sea trials following the USCG inspection, confirmed deficiency was rectified prior to heading to sea.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2018Resolved
Nonmetallic fuel hoses on both generators were worn and require replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Hoses were replaced during the inspection.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 November 2018Resolved
Fire hoses ruptured during operational test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Fire hoses was replaced during the inspection.
Engineering › Steering Gear System › Follow-up Assembly
Issued 9 December 2016Resolved
Vessels steering system failed to operate in NFU mode due to crossed wiring.
Due 9 December 2016
Resolved 9 December 2016
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Serviceable
Issued 9 December 2016Resolved
All vessels ring buoys were fitted with non-approved reflective tape.
Due 9 December 2016
Resolved 9 December 2016
Resolution: Corrected on the spot.
10 May 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 8132231
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.