← All vessels
ARKLOW SPIRIT
ARKLOW SPIRIT is a 2013 freight ship. The Coast Guard has recorded 7 inspections since 2014, most recently in April 2026, along with 5 deficiencies and 1 operational control.
Records from 2014 to 2026. Most recent: inspection, 30 April 2026.
- Built
- 2013
- Last inspected
- 30 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9649536 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
EIOF4
1277524
Flag
IRELAND
—
Maury page id
psix-1277524
Inspections, by type
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it34905 - Dead Weight, Ton
43712 - Displacement, Ton
11989 - Convention (Subpart B), Net Ton
22868 - Convention (Subpart B), Gross Ton
43712 - Displacement, Ton
11989 - Convention (Subpart B), Net Ton
22868 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
30 April 2026
PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8353414
23 April 2024
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7899980
28 August 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7545158
13 May 2021
PSC B · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7187206
18 September 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6269712
14 September 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6266233
19 June 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4893160
Deficiency record · 5
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2024
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF THE PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED.
03 PURIFIER CONTROL MODULES HAD DAMAGED MOUNTS AND EXPOSED LIVE ELECTRICAL WIRES.
74 SOLAS(20) II-1/40.1.3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021
Resolved
The fixed fire detection and fire alarm system required in paragraph 4.1.1 shall be so designed and the detectors so positioned as to detect rapidly the onset of fire in any part of thoes spaces and under any normal conditions of operation of the machinery and variations of ventalation as required by the possible range of ambient temperatures. PSCO observed cooling ventalation directed directly to the overhead heat detector outboard of the generator from the engine room ventalation system rendering the heat detector unable to function as designed. 74 SOLAS (14) II-2/7.4.2, Action taken 50 a. c.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 September 2017
Resolved
Vessel is required to submit an Advanced Notice of Arrival at least 24 hours prior to entering the port of destination. The vessel failed to submit an ANOA until they had been moored in Providence, RI for approximately 9 hours and had been prompted to by the USCG. 33CFR164.212(a)(4)(ii)
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 September 2017
Resolved
"OIL FILTERING EQUIPMENT SHALL BE OF A DESIGN APPROVED BY ADMINISTRATION. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVALS THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. DATA LOGGER DISPLAYED INCORRECT DATE + TIME, PREVENTING EXAMINERS FROM VIEWING (8 MO NTHS OF DATA AS REQUIRED BY MEPC. 107(49)
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 14 September 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.