ABYSSINIAN is a 2014 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in October 2025, along with 8 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2016 to 2025. Most recent: inspection, 20 October 2025.

Built
2014
Last inspected
20 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 October 2025
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9646728
1277557
Flag
MARSHALL ISLANDS
Maury page id
psix-1277557

Documentation record

Tonnage as PSIX records it36064 - Dead Weight, Ton
24247 - Convention (Subpart B), Gross Ton
12032 - Convention (Subpart B), Net Ton
46074 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

20 October 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8255432
14 October 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8251364
11 September 2023 Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7789234
24 July 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7512285
9 April 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7427749
22 August 2020 PSC B · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7033811
23 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6942736
2 June 2017 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6160062
6 February 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6084407
14 January 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6070927
12 July 2016 COE-Offshore · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5930402

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
Flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the Administration. Port State Control Officers observed flammable liquids stored in rope locker with no fire detection or suppression systems installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 19 September 2023
Resolution: Received photographs attesting to the proper stowage of flammable liquids to a suitable location with fire detection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2022 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. PSCO observed Main Engine Electronic Control System (WECS) malfunction on the #1 M/E cylinder, requiring software and system updates. 74 SOLAS (2014) II-1/31.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2022
Resolved 28 July 2022
Resolution: Received, reviewed and accepted class report from ABS stating the deficiency was rectified. Vessel acquired new Flex Control Modules from maker and completed new install and found WECS fully operable.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 August 2020 Resolved
11104 - Rescue boats- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the vessel's rescue boat was unable to start. SOLAS 74 (2014) III/20.2 17A/C
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2020
Resolved 28 August 2020
Resolution: Vessel provided an ABS class report attesting to the proper function of the equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2020 Resolved
13101 - Propulsion main engine - Means shall be provided to keep the starting air pressure at the required level where internal combustion engines are used for main propulsion. PSCO received notification that the vessel had a propulsion failure while maneuvering to berth due to an inoperable air compressor. SOLAS 74 (2014) II-1/53.4.5 17A/C
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2020
Resolved 28 August 2020
Resolution: Vessel provided an ABS class report attesting to the proper function of the equipment.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2020 Resolved
08199 - Other (alarms)- Bulk carriers shall be fitted with water level detectors in any dry or void space other than chain cable locker, any part of which extends forward of the foremost cargo hold, giving an audible and visual alarm at a water level of 0.1 M above the deck. PSCO was informed that the water ingress sensors in the forward void space was inoperable. SOLAS 74 (2014) XII/12.1.3 17A/C
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2020
Resolved 28 August 2020
Resolution: Vessel provided an ABS class report attesting to the proper function of the equipment.
Documentation › Logs/Records › Oil Record Book
Issued 12 July 2016 Resolved
1710- Oil record book- The Oil Record Book Part I shall be completed on each occasion, on a tank-to-tank basis if appropriate. PSCO observed numerous entries in the Oil Record Book (ORB) Part I that do not match onboard daily sounding sheets, furthermore there are numerous illegible corrections in the ORB making verification difficult. MARPOL 73/78 Annex I/17.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2016
Resolved 14 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 12 July 2016 Resolved
Safe and efficient means of ascertaining the amount of oil contained in any tank shall be provided. PSCO observed sight glass on Incinerator Sludge Settling Tank was full, C/E stated tank contained .9 M3 and sight glass was inoperable. C/E stated soundings were completed by monitoring transfer pump discharge quantities. 74 SOLAS (am) II-2/4.2.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2016
Resolved 14 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying teh requirment.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 12 July 2016 Resolved
2560-Company verification, review, and evaluation- The company should ensure that inspections are held at appropriate intervals, appropriate corrective action is taked, and records of these activities are maintained. PSCO observed the review of the ORB required by SMS was not completed per schedule. Additionally, several engineering SMS procedures had not been performed. 74SOLAS(am)IX/3;ISM A/10.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 July 2016
Resolved 14 January 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.